Gate Valve Parametric Study
Gate Valve Parametric Study
MODEL OF GATE VALVE:
SECTIONAL VIEW OF THE GATE VALVE:
EXTRACTED FLUID VOLUME:
MESHING:
CASE 1: FOR 5mm LIFT OF THE GATE VALVE DISC
1.1. SECTIONAL VIEW OF THE EXTRACTED FLUID VOLUME:
1.2. RESULTS:
1.2.1. RESIDUALS PLOT:
1.2.2. MASS FLOW RATE: 0.12364Kg/s
1.2.3. VELOCITY CONTOUR
1.2.4. ANIMATION
LINK TO THE ANIMATION:
https://drive.google.com/open?id=198m-e6yAm56xQcmaX72B2Bi3wULwoxbq
CASE 2: FOR 10mm LIFT OF THE GATE VALVE DISC
2.1. SECTIONAL VIEW OF THE EXTRACTED FLUID VOLUME:
2.2. RESULTS
2.2.1. RESIDUALS PLOT:
2.2.2. MASS FLOW RATE: 0.14869Kg/s
2.2.3. VELOCITY CONTOUR:
2.2.4. ANIMATION
LINK TO THE ANIMATION:https://drive.google.com/open?id=1tE3ZAO3NS3h_eiBosUUeDkb8x-9TGedW
CASE 3: FOR 15mm LIFT OF THE GATE VALVE DISC
3.1. SECTIONAL VIEW OF THE EXTRACTED FLUID VOLUME:
3.2. RESULTS
3.2.1. RESIDUALS PLOT
3.2.2. MASS FLOW RATE:0.18778 Kg/s
3.2.3. VELOCITY CONTOUR:
3.2.4. ANIMATION:
LINK TO THE ANIMATION:https://drive.google.com/open?id=1CnExTNYKfdWYYM66wtmhhw0CA2dmiOSR
CASE 4: FOR 20mm LIFT OF THE GATE VALVE DISC
4.1. SECTIONAL VIEW OF THE EXTRACTED FLUID VOLUME:
4.2. RESULTS:
4.2.1. RESIDUALS PLOT:
4.2.2. MASS FLOW RATE :0.23799 Kg/s
4.2.3. VELOCITY CONTOUR:
4.2.4. ANIMATION
LINK TO THE ANIMATION:https://drive.google.com/open?id=1-9XUJl5kOzBTxJixmnoma8rujmSXe8hG
CASE 5. FOR 25mm LIFT OF THE GATE VALVE DISC
5.1. SECTIONAL VIEW OF THE EXTRACTED FLUID VOLUME:
5.2. RESULTS:
5.2.1. RESIDUALS PLOT
5.2.2. MASS FLOW RATE: 0.29792 Kg/s
5.2.3. VELOCITY CONTOUR:
5.2.4. ANIMATION
LINK TO THE ANIMATION:https://drive.google.com/open?id=1aLlQsKDq0_EhED80yZmulEaNTpk8OaJk
CONCLUSION:
- The parametric study was conducted successfully for different inlet conditions.
- With the increase in the lift of the gate valve disc, the mass flow rate increases.
- The negative value of the mass flow rate indicates that the fluid is leaving at the outlet.