Lesson finished
Unlock all 35 lessons of Structural steel connections using RAM ConnectionsFull course ₹40,000 · paid
Bolted Shear Connection Checks per IS 800:2007 and RAM Report
A free lesson from Skill-Lync's Structural steel connections using RAM Connections course, on Grow by Skill-Lync · Last updated 16 Nov 2026 · Session: “Designing a Bolted Connection as per IS 800:2007”
What will you learn in this free Structural steel connections using RAM Connections lesson?
The instructor lists the IS 800:2007 checks for a bolted cleat angle shear connection, including edge distance, spacing, bolt shear, bearing, block tearing and combined shear and tension, with clause numbers. The lesson then reviews a RAM Connection design report for a beam to column flange joint.
- Minimum and maximum edge and end distance
- Bolt spacing rules in clauses 10.2.2 and 10.2.3
- Bolt shear, bearing and block tearing capacity
- Interaction ratios in a RAM Connection report
What comes after lesson 3?
Later in Skill-Lync's Structural steel connections using RAM Connections course (paid): lesson 4, Design of Fillet Welded Shear Joint as per IS 800:2007; lesson 5, Structural Steel Connections Design using RAM Connection; lesson 6, Design of Moment Connection as per IS 802:2007. The full course has 35 lessons (17 h 18 min of video); see the course overview or its price and syllabus.
Lesson transcript
Machine transcript of the lesson audio (lightly cleaned). Technical terms may contain errors; the video is the reference.
Start of Session 3. In the earlier session, we have discussed about Moment Rotation Diagram, various types of connections, and we have discussed shear connection and moment connection differences and their advantages and disadvantages. In this session, we are going to discuss about how to design a bolted connection by means of shear as per IS800-2007 and what are the necessary checks that needs to be performed in accordance to the IS800 code. In this slide, as you can see, there is a typical shear connection example has been considered for this to understand.
It is a very typical and general connection between a beam and a column where the beam is connected by a cleat angle with the help of four number of bolts where two number of bolts are connected to cleat and the beam web and two number of bolts are connected to the cleat and the column flange. So, kindly follow my cursor as we are going to discuss each of these points and we are going to skip over a few slides to look into the IS code provisions on this particular clause.
Steps to check, design a bolted shear connection as per IS800-2007. The first check that one needs to perform is a check for edge distance in a cleat angle, beam, and supporting column flange as per code provision 10.2.4. We are going to skip to the code provision. As you can see, on the right-hand side, 10.2.4 clause describes the criteria for edge and end distances. The edge distance is the distance at the right angles to the direction of stress from the center of a hole to the adjacent edge.
And the end distance is the distance in the direction of the stress from the center of a hole to the end of the element. The next verse discusses about requirement of slotted holes and oversized holes. We are going to look into clause number 10.2.4.2 where it deals with the minimum edge distance and end distance. It says that the minimum edge distance and end distance is from the center of any hole to the nearest edge of a plate shall not be less than 1.7 times of the hole diameter in the case of a sheared and hand-flamed cut edges and 1.5 times the hole diameter in case of a rolled or machine-flamed cut sawn or planned edges.
And the clause number 10.2.4.3 is also important to us where it discusses the maximum edge distance to the nearest line of the fastener from the edge of any unstiffened part should not exceed 12 times T into epsilon where epsilon is 250 by Fy root over square and T is the thickness of the thinner outer plate. This is the maximum edge distance. The clause for the minimum edge distance is 10.42.4.2 and we would be needing this 10.2.4.2 as the rule of thumb or a guideline for designing a connection.
We will go back to this previous slide. The next check is to check for spacing minimum and maximum pitch between bolts as per clause number 10.2.2 and clause number 10.2.3 applies for both horizontal and vertical spacings. We will skip to clause number 10.2.2. This is the IAS clause number 10.2.2 with minimum spacing criteria. The distance between the centers of fasteners shall not be less than 2.5 times the nominal diameter of the fastener. And the maximum spacing criteria has some sub-parts into it. We are going to discuss on these sub-parts.
It says the distance between the centers of any two adjacent fasteners shall not exceed 32 times the thickness or 300 mm whichever is less but T is the thickness of the thinner plate. So, again, as we discussed on the edge distance and end distances, the minimum edge and end distance only will be our governing criteria for designing any joint. Similarly, for any fastener spacing, the minimum spacing criteria will be a governing criteria for designing the joint. We are going to go over the other clauses under this maximum spacing criteria so that we cover all the possible scenarios.
The maximum distance criteria 10.2.3.2 says the distance between the centers of two adjacent fasteners in a line lying in the direction of the stress shall not exceed 16 times the thickness or 200 mm whichever is less in tension member and 12 times the thickness or 200 mm whichever is less in compression member where T is the thickness of the thinner plate. In case of a compression member wherein forces are transferred through the butting faces, this distance shall not exceed 4.5 times the diameter of the fastener for distance equal to 1.5 times the width of the member from the butting faces.
So, the first clause is a generalized clause where the distance between two adjacent fasteners are not necessarily in line with the stress. So, this is an overall generalized criteria where 32 times the thickness or 300 mm whichever is less should be considered as the maximum width distance or maximum spacing between any two adjacent fasteners. But when the force is acting along the minimum distance between any two adjacent fasteners, then for the plate which is under tension, the clause says 16 times minimum plate thickness or 200 mm.
And for compression, it says 12 times the thickness of the minimum plate thickness or 200 mm whichever is less. We will come back to the previous slide. The next is to check shear capacity of any bolt group as per clause number 10.3.3. So, we will go to clause number 10.3.3 as per IS code. The clause 10.3.3 says the criteria for shear capacity of bolt. It says the design strength of bolt as governed by shear strength is given by VNSB by gamma MB. Where VNSB is nominal shear capacity of bolt calculated by this following formula.
This is Fu over root 3 multiplied by N times ANB plus NS times ASB. Where Fu is the ultimate tensile strength of a bolt. And N is number of shear planes with thread intercepting the shear plane. NS are the number of shear planes without the threads intercepting the shear plane. ASB is the nominal plane shank area of the bolt. And N is the net shear area of the bolt at threads. We will move back to the previous slide. The next check for design of a bolted shear connection is to check for the shear capacity of the plate as per clause number 8.4.
We will go to clause number 8.4 of the code. Clause says that the factored design shear force in a beam due to external actions shall satisfy V is less or equal VD. Where VD is the design strength. And VD is defined by VN over gamma M0. Gamma M0 is the partial safety factor against shear failure and can be found out at clause number 5.4.1 of the code. The nominal shear strength of a cross section VN may be governed by plastic shear resistance or strength of the web as governed by shear buckling.
And the nominal plastic shear resistance under pure shear is given by VN equal VP where VP can be found out by this formula of AVFYW over root 3. AV is the shear area with FYW is the yield strength of the web. In the clause number 8.4.1 the shear area calculations of various items can be found out. And these are helpful for understanding how to calculate shear area and come up to nominal shear strength of the plate or concerned. Coming back to this design steps. The next is to check for bolt bearing due to tension as per clause number 10.3.4.
We will go to clause number 10.3.4 in the IS code. The IS code clause 10.3.4 gives us a criteria for bearing capacity of the bolt. The design bearing strength of a bolt on any plate VDPB as governed by the bearing stress is given by VNPB over gamma Mb. VNPB is the normal bearing strength of a bolt. A normal bearing strength of a bolt is achieved by this formula. 2.5 times KB into D into T into FU. KB is defined by the smaller of E over 3 times D0 and P over 3 times D0 minus 2.25.
FU P by FU and 1. So smaller of these 4 items is given by the value of KB. Where E and P are end and pitch distances of the fastness along the bearing direction. D0 is the diameter of the hole. FU P and FU are basically the ultimate tensile stress of the bolt and ultimate tensile stress of the plate respectively. T where it is used in this formula 2.5 times KB DT FU. Where T is the summation of the thickness of the connected plates experiencing bearing stress in the same direction.
Or if the bolts are countersunk the thickness of the plate minus one half of the depth of the countersink. Coming to the next segment of this criteria. There are certain amount of coefficients provided here to reduce the bearing stress resistance for the conditions of oversize and short slotted holes and long slotted holes. These are multiplying factor for VNPB. We will go back to the previous slide. The next check that needs to be considered for bolted shear connection design is to check for... For block tearing due to tension as per clause number 6.4.1. We will go to the slide where IS code number, clause number 6.4.1 is explained.
In this clause 6.4.1, the criteria in the code says that block steering strength Tdb of connection shall be taken as the smaller of these two formula. Tdb is equal to the summation of AVGFY over root 3 gamma 0 plus 0.9ATNFU over gamma M1 or Tdb is equal 0.09AVNFU over root 3 gamma M1 plus ATGFY over gamma M0. In this case, we need to understand AVG and AVN are basically minimum gross and net area of shear along bolt line parallel to external force respectively. And the reference can be drawn from figure number 7.A and 7.B.
Whereas ATG and ATN are basically minimum gross and net area in tension from the bolt hole to the toe of the angle end bolt line perpendicular to the line of force respective. The reference can be made to figure number 7.FU and FY are nothing but ultimate and yield stress of the material respectively. The final check that one needs to perform for bolted shear connection is that the code also suggests checking for the bolts subjected to combined action of shear and tension as per clause number 10.3.6.
We will go to the clause number 10.3.6 and review how the criteria is defined. On this slide, the clause 10.3.6 in IS800 is the criteria for bolts subjected to combined shear and tension. Where the clause says a bolt is required to resist both design shear force VSD and design tensile force TB at the same time shall satisfy VASB over VDB whole square plus TB by TDB whole square less or equal 1.0. So basically, VASB is the factored shear force acting on the bolt and VDB is the design shear force capacity of the bolt as per 10.3.2.
TB is the factored tensile force acting on the bolt and TD is the design tension capacity as per clause number 10.3.5. So a quick reference to clause number 10.3.2 and 10.3.5 would also be necessary in this regard. So, as per this slide, design of bolted shear connection, all the necessary checks that we have concluded are already discussed. In the next stage of this discussion, we are going to review a design report generated from RAM connection and we are going to review the clauses as well for various design checks that the report is generating and whether the clauses are satisfactory as per IS code or not.
This is a walkthrough of bolted shear connection as per RAM connection module and we are going to review a design report generated from RAM connection software. So, this is a design report that has been generated from RAM connection. This report is made for a beam column flange typical connection by the means of shear connection and, of course, with bolted connections. If you can see that the design code is mentioned as IS8002007 and here we are going to review this connection with the help of this much load where PU is vertical shear that is 2 tons which is basically 20 kilonewtons and IU is nothing but axial shear force which is 10 kilonewtons in this case mentioned as 1 ton.
So, the initial checks that RAM connection software does are the geometrical considerations. You might see that there are certain checks which RAM connection have performed here which does not align with or the references of such checks are not provided in IS800 code. So, these are basically considered from various different references as well as other books. So, initially, the geometrical consideration is started by checking the adequacy of the connector's length. In this case, the length has been checked by a minimum and maximum formula which is not as per the code but it is from some other references.
So, we are not going to discuss on detail on how to do these sort of checks from these references because these does not come under the purview of this session but we are going to discuss about the other checks that have been performed here which are as per the code clause. Next, coming to the connectors vertical edge distance and horizontal edge distance checks. So, as we have seen already from clause number 10.2.4 and its sub clauses, a maximum and minimum edge distance and end distance are provided.
If you can see that the minimum end distance is governed by the formula of 1.5 times dh. Similarly, the horizontal edge distance is also calculated based on 1.5 times dh where dh is the diameter of the hole. Going to the next page, this is the maximum edge distance checked as per clause number 10.2.4.3 where 12 times the thickness into epsilon was the formula as per our code and the check has been performed accordingly. Coming to the next check, it is the vertical center to center spacing or pitch distance between the fasteners.
This is as per clause number 10.2.3.3 where we have seen that the clause says 2.5 times the diameter of the nominal diameter of the anchor or the fastener is the governing criteria. In this case, the P minimum is also calculated similarly like this 2.5 times the nominal diameter and the P maximum is also calculated from this formula which is the minimum of 100 mm plus 4 times the thickness and 300 mm whichever is lesser. Based on that, this check has been performed. Moving on, the next check is done for the vertical edge distance of the connector.
Similar to the previous example, 10.2.4.2 and 10.4.3 allows us the minimum and maximum edge distance criteria and that is again 1.5 times diameter of the hole and 12 times the T into epsilon. These two will give us the governing criteria to check the spacing of the vertical edge distance of the connector at the support side. The support side means the connector is connected to the flange side of the column. So, the edge distance is considered with respect to the beam web and as well as the column flange.
Similarly, as the vertical edge distance or horizontal edge distance are also checked in accordance to 10.2.4 clause as per the code. And the vertical center center spacing or pitch is also checked with respect to the clause of 10.2.3.3. Now, we'll come to the location of a beam side where vertical center spacing is checked. In the beam web also, we need to consider the pitch distance checked as well as the horizontal edge distance as per the code. So, in this case, again, the pitch distance is checked by the clause 10.2.3.3 and the minimum and the maximum criteria is also given in the clause.
Accordingly, the check has been performed 2.5 times the nominal diameter and P max is the minimum 100 mm plus 4 times the thickness or 300 mm whichever is less. For the horizontal edge distance in the beam web, similar, the minimum edge distance has been considered as 1.5 times the diameter of the hole and the maximum edge distance is also considered as 12 times thickness of the epsilon. Based on this, geometrical check has been performed for the beam side. Coming to the support side, which is basically the column flange, there also a pitch distance and a horizontal center spacing distance dot or the gauge distance are checked with respect to the codal clause of 10.2.3.3 and the horizontal edge distance is also checked as per 10.2.4.
The formulation of these vertical pitch and gauge distances are same for the P minimum and P maximum as well as the horizontal edge distance are also as per the code clause with similar formula of 1.5 times the edge and 12 times thickness of the plate into epsilon. Coming to the next step of this design verification report, this step allows us to understand and review the shear capacity of angle and the beam side and angle at the support side. In this case, as per the IS code number, clause number 10.3.3, for the calculation of the bolt group shear VDSB, which is formulated by 2 times VNSB over gamma NB, this VNSB has to be calculated, that is, the nominal shear force.
Nominal shear force is formulated as per FU over root 3 multiplied by NN into ANB plus NS into ASB and the calculation of ASB and ANB are provided in such a manner. Once this VNSB is calculated, the same formulation in the VDSB calculation it has been provided and the bolt group shear has been calculated. In the next step, we are going to review the calculated or the allowable bolt group shear with the calculated bolt group shear. In this case, we have calculated the bolt group shear by the means of shear force divided by number of bolts plus eccentric moment into inverse of section modulus whole square on either side of the group.
So, this allows us to have two different calculated bolt group shear forces and this maximum of these two shear forces are reviewed against the allowable force and the design aspect ratio has been calculated as per that. Scrolling to the next check, which is bolt bearing as per clause number 10.3.4. As the development of the Forms number 10.3.4 said that the bolt bearing can be calculated by VDB is equal VNPB over Gamma MB. Now VNPB needs to be calculated based on 2.5 times KB into D into T into FU where KB is again calculated by the minimum of E by 3D0 or P by 3D0 minus 0.25 or FUB by FU and 1.
Minimum of these are calculated and you can see the minimum value is calculated as for 0.606 and from this value and the other values of DT and FU we can see that the VNPB has been calculated as 10.14 and that gives us a bolt bearing capacity of 8.11 whereas the calculated bolt bearing capacity is bolt bearing is only 0.872 and checking with that gives us a bolt interaction. bearing interaction ratio of only 0.07. Coming to the next shear check. This is a shear check at gross section which is done as per 8.4.1 and clause 8.4.
Shear at gross section is calculated by this formula mentioned from clause number 8.4 and this formula is checked against the applied shear force that is 1 tonne and the shear capacity ratio design aspect ratio is checked accordingly. After this shear at gross section, the shear at net section is also similarly checked as per clause number 8.4 and similarly the same shear is checked against the shear value applied. The next check that is done is for the block tearing. So as per block tearing clause number 6.4.1 we know that the block tearing capacity is calculated as TdB which is equals to 2 times this formula of minimum of AVG Fy over square root of 3 gamma M0 plus 0.9 ATN FU over gamma M1.
The minimum of these two will come as the block tearing capacity and that has been calculated over here as 46.08 which has been checked with the applied shear force. Similarly, bolt bearing due to tension is also cross section based on clause number 10.3.4 which we have already covered during our understanding of the checks that needs to be performed. And if you can see, bearing capacity of VNPB is given by VNPB is equal to 2.5 times KB times T times T times Fu where KB is calculated as minimum of E1 by 3 times T0 and P by 3 times T0 minus 0.25 and Fu P by Fu and 1 which is calculated as 0.606 hence the formula gives us the bearing capacity which is 8.11 and thus it has been calculated and checked for the capacity of the bolt bearing due to tension.
Similarly, block tearing due to tension is also cross checked as per clause number 6.4.1 and if you can see that again the tearing capacity has been calculated for the minimum of these two formulas and it has been cross checked against the applied shear force over here. Now, it is the beam side where all the checks are being performed. So, on the beam side the beam is connected to the connector by the means of bolted connection. So, as we can see the initial checks are being performed for bolt bearing as per clause 10.3.4.
Then, shear at gross section is checked again as per clause 8.4. One needs to be careful about the check interaction ratio. If the aspect ratio is more than 1, then that aspect of the report has to be re-evaluated and certain design input needs to be altered in order to get the interaction ratio less than 1. Then, it satisfies the clause as it were selected. Similarly, after shear check at gross section, the shear check at net section is also performed as per clause 8.4 for the beam.
Scrolling down, the block tearing due to tension also is checked as per clause 6.4.1 and block bearing due to tension also checked as per clause 10.3.4. Then, the checks are being performed for the angle which is at the support side. So, as we understand that this shear connection bolted is connected to the flange of the column by the means of bolted connection again. So, the angle connector needs to be cross verified at the beam side as well as the support side. Similar cross checks are done for the beam side as well as for the support side.
As you can see, it starts with bolt group shear with the check as per clause 10.3.3 and then it follows up with the bolt bearing as per clause 10.3.4. Then, the angle bending is checked. So, when I come to discuss about the bending of the angle, we need to understand that the beam transfers the forces by the means of the bolt which is connected to the beam web. Then, the force gets traveled through the angle connector and then it gets transferred into the column flange. So, there happens to be some amount of eccentricity from the face of the column flange to the centerline of the beam bolt holes.
This eccentricity gives us the bending that is necessary for the connector angle to bear and in order for it to be safe and transmit all the forces. This bending check has been performed as per clause 8.2.1.2 and next the shear check at gross section is also confirmed as per clause 8.4. Following to that, shear at net section and block tearing are also checked as per clauses 8.4 and 6.4.1. The prying moment of the angle connector is something which is checked as per a different reference in this software.
This is not covered as per IS800. So, we are not going to cover under this scope of the session. Coming to the next part, the bolt tension is checked as per clause number 10.3.5. This is the tensile force calculated as per the ultimate tensile stress and the nominal bow diameter of the anchor rod. Following to this, we scroll down and check that there are calculations provided for support location which is basically the column flange. So, for the column flange, the initial check has been performed for web local shear as per clause number 8.4.
Then there are checks performed for bolt group bearing and hence we come to the conclusion of the global critical strength ratio. So, as you can see that the design aspect ratio has always been produced over here for each of the check headers. And this global strength critical ratio is the maximum of all those in design aspect ratios. And this is the governing criteria for which this design check has been performed. And other checks are also considered and performed simultaneously for us to understand whether the governing criteria needs to be tweaked or needs to be modified in such a way that the other checks which are already performed does not get affected.
So, as you can see in RAM connection report itself, they mention and also I have also mentioned in the previous during the initiation of this report description that some verifications for these connections are not available in IS 800-2007 and thus have been calculated with BS EN 1993 and some other references as well. Scrolling down to this further, you would see that there have been notations which are provided for all the symbols that have been utilized over here. So, one can go through this to understand what are the symbols mean and that concludes this report.
End of session 3.