Power Plant Engineering
Follow the energy through a 660 MW coal unit, size its condenser and cooling tower, run a reactor on a reactivity step and price a unit of electricity
28 chapters, 28 interactives, few words. This book covers the power plant engineering course of mechanical engineering: the energy flow and heat balance of a supercritical coal unit, steam and heat rate, cogeneration, coal and ash handling, firing systems and fluidised beds, high-pressure boilers, boiler efficiency, draught, economisers and air preheaters, feedwater treatment, condensers and cooling towers, diesel and gas turbine plants, combined cycles, nuclear fission, reactor physics, control and reactor types, safety and waste, hydroelectric and renewable plants, load curves, the cost of power, tariffs and pollution control. One plant, one coal and one site run through the whole book, so the numbers in one chapter carry into the next.
- AUCME384Power Plant Engineering
- VTUBME515DEnergy Engineering
- SPPU402049Energy Engineering
- MUMEC602Turbo Machinery (Module 1: steam generators)
- KTUPEMET631Power Plant Engineering
By Skill-Lync · Updated 24 Nov 2026 · 28 chapters · 28 interactives · free, no sign-up
Power plants in India and the energy flow through a coal-fired unit
Which syllabus covers thisAU CME384 Unit I (layout of modern coal power plant)VTU not in syllabusSPPU 402049 Unit 1 (energy scenario, plant circuits, site selection)MU MEC602 Module 1 (layout of thermal power plant)KTU PEMET631 Module 3 (general layout, site selection)
How much of India's electricity still comes from coal?
On 31 October 2026 India had 563,113 MW installed (CEA). Coal was 225,068 MW, 39.97 % of it; renewables 251,149 MW (44.6 %, of which solar 174,547 MW); large hydro 9.3 %; gas 3.4 %; nuclear 1.6 %. Capacity is not energy. A solar panel works only in daylight, so in FY 2025-26 renewables (as CEA counts them) gave 17.6 % of the 1,761 billion kWh generated, and the grid emitted 0.675 t of CO2 per MWh on average. Coal still carries most of the energy, which is why this book starts with a coal unit.
Where does the coal's energy go in a modern 660 MW unit?
Follow THE PLANT, the book's 660 MW supercritical unit. Coal brings in 1,621 MW of heat. The boiler loses 211 MW (13 %) up the stack and in ash. 1,410 MW goes into steam. The turbine turns 670 MW of it into shaft work; the condenser throws away 740 MW, 45.7 % of the coal, into cooling water at about 42 °C. The generator loses 10 MW, the unit's own fans, pumps and mills take 39.6 MW, and 620.4 MW leaves for the grid: 38.3 % net efficiency.
What are the four circuits of a coal plant?
1. Coal and ash: wagons, crusher, bunkers, mills and burners in; bottom ash and fly ash out. THE PLANT burns 366.8 t of coal an hour and makes 139 t/h of ash, because Indian coal is 38 % ash. 2. Air and flue gas: forced draught fans push 632 kg/s of air through the air preheater to the furnace; induced draught fans pull 523 Nm³/s of flue gas through the precipitator to the chimney. 3. Feed water and steam: 1,893 t/h of steam round the boiler, turbine, condenser and heaters. 4. Cooling water: 17,711 kg/s between condenser and cooling tower.
How much do better steam conditions save?
Run the same 660 MW unit three ways, everything else equal. Subcritical (16.7 MPa, 538/538 °C, assumed typical of 500 MW sets): 36.53 % net, 384 t/h of coal, 0.908 kg CO2/kWh. Supercritical (THE PLANT, 24.2 MPa, 565/593 °C, NTPC Darlipali's conditions): 38.27 %, 367 t/h, 0.867 kg. Ultra-supercritical (26 MPa, 600/600 °C, assumed): 38.97 %, 360 t/h, 0.851 kg. The jump from sub to ultra-supercritical saves 24 t of coal every hour. CEA assumes 0.87-0.89 t/MWh for real 660 MW units and 0.85 for 800 MW units.
What decides where a coal plant is built?
Five things, in this order. Water: the cooling tower loses water to evaporation every hour, so a reliable river, canal or reservoir is needed. Coal: THE PLANT needs about 8,804 t a day, so pit-head sites near the mines or a firm rail linkage win. Rail and roads: for coal in and equipment during construction. Land: the main plant, a coal stockyard holding weeks of coal, and room for ash. Ash: 3,345 t a day must go to cement, bricks and roads or to an ash pond. Then grid connection, distance from towns and airports, and soil that can carry heavy foundations.
Of the coal heat that enters THE PLANT, where does the biggest single share go?
The condenser takes 740 MW, 45.7 % of the 1,621 MW of coal heat. The grid gets 38.3 %, the boiler loses 13 % and the auxiliaries 2.4 %. Steam must give up its latent heat to condense before it can be pumped back, and that heat is at only about 46 °C.
Worked examples
Coal per hour and per day from the heat rate · THE PLANT: 660 MW gross, turbine-cycle efficiency 47.51 %, generator 98.5 %, boiler 87 %, coal GCV 3,800 kcal/kg
- GCV = 3,800 × 4.1868 = 15,910 kJ/kg
- Gross unit heat rate = 3,600/(0.4751 × 0.985 × 0.87) = 8,842 kJ/kWh = 2,112 kcal/kWh
- Coal = 660,000 kW × 8,842 kJ/kWh ÷ 15,910 kJ/kg = 366,814 kg/h = 366.8 t/h
- Per day: 366.8 × 24 = 8,804 t; ash at 38 %: 3,345 t/day
Answer: 366.8 t/h, about 8,804 t of coal and 3,345 t of ash a day
CO2 per kWh from the coal's carbon · THE COAL: 40 % carbon, burnt completely; coal 366.8 t/h; net output 620.4 MW
- C + O2 → CO2: 12.011 kg of carbon gives 44.009 kg of CO2, so 1 kg of coal gives 0.40 × 44.009/12.011 = 1.4656 kg CO2
- CO2 per hour = 366.8 × 1.4656 = 538 t/h
- Per kWh sent out: 537,611 kg/h ÷ 620,400 kWh/h = 0.867 kg/kWh
- Per MJ of coal heat: 1.4656/15.91 = 92.1 g/MJ, against CEA's 92.5 g/MJ for Indian coal
Answer: 0.867 kg CO2 per kWh, close to CEA's 0.87-0.89 for 660 MW units and 1.28 times the grid average of 0.675
Is the unit inside CERC's heat-rate norm? · CERC 2024: for 247 kg/cm², 565/593 °C units the design turbine-cycle heat rate may be at most 1,850 kcal/kWh with boiler efficiency at least 86 %; the station norm is 1.045 × design unit heat rate. THE PLANT: turbine-cycle heat rate 7,693 kJ/kWh, boiler 87 %
- THE PLANT's turbine-cycle heat rate = 7,693/4.1868 = 1,837 kcal/kWh: below the 1,850 cap
- Worst design unit heat rate CERC allows = 1,850/0.86 = 2,151 kcal/kWh
- Station heat-rate norm = 1.045 × 2,151 = 2,248 kcal/kWh
- THE PLANT's gross unit heat rate = 8,842/4.1868 = 2,112 kcal/kWh, 6.1 % below the norm
Answer: Yes: 2,112 kcal/kWh against a norm of 2,248, so the margin covers part-load running, starts and ageing
Rankine cycle improvements in a real plant: supercritical steam, reheat, feedwater heaters and the heat rate
Which syllabus covers thisAU CME384 Unit I (Rankine cycle improvisations, super critical boilers)VTU not in syllabusSPPU 402049 Unit 1 (Rankine cycle with reheating and regeneration)MU not in syllabusKTU PEMET631 Module 1 (mean temperature of heat addition, reheat, regeneration)
Why does hotter, higher-pressure steam raise the efficiency?
A steam cycle behaves like a Carnot engine working between the mean temperature at which it takes in heat, Tm = Δh/Δs over the boiler, and the condenser temperature T0. For THE PLANT q_in = 2,683 kJ/kg over Δs = 3.953 kJ/(kg·K), so Tm = 679 K (406 °C) and 1 − T0/Tm = 52.9 % with T0 = 319.5 K. The real cycle gives 47.5 % because turbines and heaters are not perfect. Raising pressure, superheat, reheat and feed temperature all lift Tm. Above 22.064 MPa water never boils: it warms smoothly into steam, so a supercritical boiler needs no drum.
What does reheating do?
After the HP turbine the steam (at 4.5 MPa in THE PLANT) goes back to the boiler and is heated again to 593 °C before the IP and LP turbines. Two gains. Dryness: without reheat the LP exhaust would be only 0.82 dry, and water droplets at that wetness erode the last-stage blades; with reheat it is 0.933. Efficiency: the extra heat is added at a high temperature, so the cycle goes from 44.94 % to 47.51 %, 2.6 points. Reheat also cuts the steam needed for 660 MW from 2,537 to 1,893 t/h, 25 % less. Most large units have one reheat; double reheat is rare.
Why bleed steam to heat the feedwater?
Feed leaving the condenser is at 46 °C. Heating it in the boiler means adding heat at a low temperature, which drags Tm down. Instead, small amounts of steam are bled from the turbine to heat the feed in steps, so the boiler starts from 290 °C. Bled steam has already done some work, and its latent heat goes back into the cycle instead of the condenser. THE PLANT with 0 heaters: 41.95 %; 1: 44.26 %; 4: 46.62 %; 8: 47.51 %. Each heater adds less. One heater is an open deaerator, where steam and water mix to strip dissolved oxygen.
What is heat rate and why do plants quote it instead of efficiency?
Heat rate is the heat needed per kWh: HR = 3,600/η kJ/kWh, with η as a fraction. THE PLANT's turbine-cycle heat rate (heat to steam per kWh at the generator) is 7,693 kJ/kWh, or 1,837 kcal/kWh. Plants like it because it converts straight into fuel: coal per hour = output × heat rate ÷ GCV. Going from 0 to 8 heaters lowers it from 8,711 to 7,693 kJ/kWh, 11.7 % less fuel for the same output. CERC caps the design turbine-cycle heat rate by steam class, 1,850 kcal/kWh for 247 kg/cm² and 565/593 °C units.
What stops engineers making the steam even hotter?
Metal. Superheater tubes, steam pipes and the first turbine stages must hold high pressure at red heat for 25 years or more without creeping. India's CERC heat-rate table stops at 270 kg/cm² with 600/600 °C steam, the ultra-supercritical class. In the model, raising THE PLANT's steam to 600 °C and reheat to 620 °C lifts the cycle from 47.51 % to 48.22 %. The US DOE's advanced ultra-supercritical programme (NETL) sizes parts for 760 °C steam and needs nickel superalloys such as Inconel 740 and Haynes 282, which cost many times more than steel.
THE PLANT has 8 feedwater heaters. If the engineers added a 9th, what would you expect?
The first heater lifts the cycle from 41.95 % to 44.26 %, but the 8th adds only 0.22 points. Each extra heater shares the same feed temperature rise in smaller steps, so the gain keeps shrinking while the cost of a heater, its piping and its turbine nozzle stays the same.
Worked examples
Mean temperature of heat addition for THE PLANT · Per kg of main steam: heat added in boiler and reheater q_in = 2682.7 kJ/kg, entropy rise Δs = 3.9527 kJ/(kg·K); condenser at 10.3 kPa (T0 = 319.54 K); actual cycle efficiency 47.51 %
- Tm = q_in/Δs = 2682.7/3.9527 = 678.7 K = 405.6 °C
- Ideal (internally reversible) efficiency = 1 − 319.54/678.7 = 52.92 %
- Actual 47.51 %: the turbines, pumps and heaters lose 5.4 points
- With no heaters Tm falls to 588 K and the ideal figure to 45.7 %
Answer: Tm = 679 K; no cycle between Tm and T0 can beat 52.9 %
Ideal reheat cycle with one open feedwater heater · Steam at 16 MPa, 540 °C expands to 3.5 MPa, is reheated to 540 °C, expands again; some is bled at 0.6 MPa into an open heater, the rest goes to a 10 kPa condenser. Isentropic machines. Steam tables: h1 = 3412.1, h2 = 2978.9 (3.5 MPa), h3 = 3542.2, h4 = 3005.8 (0.6 MPa), h5 = 2304.7 kJ/kg (x = 0.883); h_f = 191.81 at 10 kPa and 670.5 at 0.6 MPa; v_f = 0.00101 and 0.001101 m³/kg
- Condensate pump: v Δp = 0.00101 × 590 = 0.596 kJ/kg → 192.41 kJ/kg
- Open heater: m h4 + (1 − m) 192.41 = 670.5 → m = 0.1699 kg per kg of steam
- Feed pump: 0.001101 × 15,400 = 16.95 kJ/kg → h_fw = 687.45 kJ/kg
- Turbine work = (3412.1 − 2978.9) + (3542.2 − 3005.8) + 0.8301 × (3005.8 − 2304.7) = 1551.6 kJ/kg
- Heat in = (3412.1 − 687.5) + (3542.2 − 2978.9) = 3287.9 kJ/kg
- η = (1551.6 − 17.44)/3287.9 = 46.66 %; without the heater 43.92 %
Answer: m = 0.17, η = 46.7 %: one heater adds 2.7 points to the reheat cycle
From efficiency to heat rate and steam flow · THE PLANT: turbine-cycle efficiency 47.51 %, net work 1274.5 kJ per kg of main steam, generator × mechanical efficiency 98.5 %, 660 MW
- Turbine-cycle heat rate = 3,600/(0.4751 × 0.985) = 7,693 kJ/kWh = 1,837 kcal/kWh
- Main steam = 660,000/(1274.5 × 0.985) = 525.7 kg/s = 1,893 t/h
- Steam rate = 525.7 × 3,600/660,000 = 2.868 kg/kWh
Answer: 7,693 kJ/kWh (1,837 kcal/kWh), 1,893 t/h of steam, 2.87 kg/kWh
Steam rate and heat rate at part load: the Willans line and why units run near full load
Which syllabus covers thisAU CME384 Unit I (turbines, steam and heat rate)VTU not in syllabusSPPU 402049 Unit 5 (performance and operating characteristics)MU not in syllabusKTU PEMET631 Module 2 (governing of steam turbines)
What are steam rate and heat rate?
Steam rate is the steam a turbine needs per kWh: main steam flow ÷ output, in kg/kWh. THE PLANT needs 2.868 kg/kWh at 660 MW. It says nothing about fuel, because a kg of steam at 24 MPa carries different heat from a kg at 10 MPa. Heat rate does: heat in per kWh, in kJ/kWh. Three levels are quoted: turbine-cycle heat rate (heat to steam per kWh generated, 7,693 kJ/kWh), gross unit heat rate (coal heat per kWh generated, 8,842) and net unit heat rate (coal heat per kWh sent out after the auxiliaries, 9,407 kJ/kWh). Efficiency is 3,600 ÷ heat rate.
What is the Willans line?
For a throttle-governed turbine the steam flow plotted against load is very nearly a straight line, steam = a + b × load: the Willans line. The intercept a is the no-load flow that only keeps the machine spinning against friction, windage and throttling losses. So steam rate = b + a/load rises as load falls. In the model of THE PLANT, the heat-input line has a no-load intercept of 6 % of full-load heat with sliding pressure and 8 % with throttling. Its steam-flow line passes almost through zero, because at part load less steam is bled to the heaters and each kg does more work.
What is sliding-pressure operation?
A constant-pressure unit keeps the boiler at full pressure and closes the turbine control valves at part load. The throttled steam loses pressure and temperature at constant enthalpy, wasting part of its ability to do work: at 50 % flow THE PLANT's steam would enter the turbine at 12.1 MPa and 518 °C instead of 565 °C. In sliding pressure the valves stay wide open and the boiler pressure falls with load, so the temperature stays at 565 °C, there is no throttling loss and the feed pump works less. Once-through supercritical boilers suit it. At 50 % load the model gives 10,359 kJ/kWh sliding against 10,530 throttled, 1.7 % worse.
Why do units lose efficiency at part load?
Three reasons stack up. The cycle is worse: lower steam pressure and a cooler final feed. The no-load losses are spread over fewer kWh. And part of the auxiliary power is fixed: fans, pumps and mills do not slow down in proportion. The model assumes half the 39.6 MW of auxiliaries is fixed. At 55 % load THE PLANT's net heat rate rises from 9,407 to 10,198 kJ/kWh, 8.4 % worse, and net efficiency drops 2.97 points. That burns 16.5 t of extra coal every hour, 397 t a day. Real units also lose boiler and turbine efficiency at low load; this model holds both constant, so real part-load heat rates are worse.
Why are Indian coal units being pushed down to 40 % load?
Solar floods the grid at midday, so coal units must back down and ramp up again in the evening. The Grid Code (IEGC 2023) sets the minimum turndown of central coal units at 55 % of rated output. The CEA flexible-operation regulations of 2023 ask units to be able to run at 40 %, and to ramp at least 3 % per minute between 70 and 100 %. In the model, 40 % load raises THE PLANT's net heat rate to 10,781 kJ/kWh, 14.6 % above full load. Low load also stresses metal through temperature cycling and makes flames less stable, so mills and burners need changes.
A turbine follows a Willans line with a no-load steam flow of 10 % of its full-load flow. At half load, its steam rate (kg/kWh) is:
With a = 0.1 and b = 0.9 (per unit of full-load flow and output), steam rate = b + a/P: 0.9 + 0.1/1 = 1.0 at full load and 0.9 + 0.1/0.5 = 1.1 at half load, 10 % higher. At quarter load it would be 0.9 + 0.4 = 1.3, 30 % higher: the no-load flow hurts more and more as the load falls.
Worked examples
Steam consumption from a Willans line · A 12 MW throttle-governed turbine needs 52 t/h of steam at full load; its no-load steam flow is 5.2 t/h (10 %, assumed)
- Slope b = (52 − 5.2)/12 = 3.9 t/h per MW
- At 6 MW: 5.2 + 3.9 × 6 = 28.6 t/h; steam rate 28.6/6 = 4.767 kg/kWh
- At 12 MW: 4.333 kg/kWh; at 3 MW: 16.9/3 = 5.633 kg/kWh
- Increase over full load: 10 % at half load, 30 % at quarter load
Answer: 28.6 t/h at 6 MW; the steam rate rises from 4.33 to 4.77 kg/kWh
THE PLANT at 55 % load · Sliding pressure model at 363 MW gross: heat to steam 819 MW, main steam 275.6 kg/s; boiler 87 %; auxiliaries 39.6 MW at full load, half of it fixed; full-load net heat rate 9,407 kJ/kWh; coal GCV 15,910 kJ/kg
- Fuel heat = 819/0.87 = 941.4 MW
- Auxiliaries = 39.6 × (0.5 + 0.5 × 0.55) = 30.69 MW; net = 363 − 30.69 = 332.31 MW
- Net heat rate = 941.4 × 3,600/332.31 = 10,198 kJ/kWh (8.4 % above full load)
- Extra coal = 332.3 MW × (10,198 − 9,407) kJ/kWh ÷ 15,910 kJ/kg = 16.5 t/h
- Steam rate = 275.6 × 3.6/363 = 2.734 kg/kWh, slightly below 2.868 at full load
Answer: 10,198 kJ/kWh net, 2.97 points of efficiency lost and 16.5 t/h of extra coal; steam rate alone would hide this
Fitting a Willans line to trial data · A turbine trial gives (load MW, steam t/h): (2.5, 15.2), (5, 25.1), (7.5, 35.3), (10, 44.9)
- Means: load 6.25 MW, steam 30.125 t/h
- Slope by least squares b = Σ(x − x̄)(y − ȳ)/Σ(x − x̄)² = 3.972 t/h per MW
- Intercept a = 30.125 − 3.972 × 6.25 = 5.3 t/h (no-load steam)
- Largest misfit 0.21 t/h: the points lie on a straight line
- Steam rate at 7 MW = (5.3 + 3.972 × 7)/7 = 4.729 kg/kWh
Answer: Steam = 5.3 + 3.972 × P t/h; no-load flow 11.8 % of the 10 MW flow
Cogeneration and binary vapour cycles: back-pressure and extraction turbines and the heat-to-power ratio
Which syllabus covers thisAU CME384 Unit I (binary cycles and cogeneration)VTU not in syllabusSPPU 402049 Unit 4 (cogeneration, process heating)MU not in syllabusKTU PEMET631 Module 2 (cogeneration)
What is cogeneration and why does it save fuel?
A power-only plant must condense its exhaust at the lowest possible temperature, so THE PLANT throws 45.7 % of its coal heat into cooling water at about 46 °C, too cold for any use. A sugar mill, refinery, paper or chemical plant needs steam at 150-180 °C for heating. Cogeneration (combined heat and power) sends the turbine exhaust or bled steam to that process instead of a condenser, so the latent heat is used, not wasted. Power comes out as a by-product of the process steam. Sugar mills burning bagasse and refineries are India's classic cogeneration users.
Back-pressure or extraction-condensing turbine?
A back-pressure turbine exhausts all its steam at the process pressure. For the assumed plant (8.7 MPa, 510 °C steam, 30 MW of heat at 0.5 MPa) it passes 13.6 kg/s and makes 7.4 MW, with no condenser loss at all: 82.5 % of the fuel is used. But its power is fixed by the heat demand. If the factory needs 10 MW, it must buy 2.6 MW from the grid. An extraction-condensing turbine bleeds the process steam and sends the rest, here 2.63 kg/s, to a condenser to make up the power. It follows any demand but uses only 72 % of its fuel.
What sets the heat-to-power ratio?
Heat-to-power ratio = process heat ÷ power. A back-pressure turbine has no freedom: each kg of steam gives (h1 − h_exhaust) of work and (h_exhaust − h_f) of heat, so the ratio depends on the steam conditions. For the assumed plant with 30 MW of heat, process steam at 0.3 MPa gives 8.33 MW (ratio 3.6); at 0.5 MPa 7.4 MW (4.05); at 1.0 MPa only 6.03 MW (4.98). Higher boiler pressure or a lower process pressure means more power per tonne of steam. Match the turbine to the factory's own ratio.
How do you judge a cogeneration plant?
Energy utilisation factor EUF = (power + useful heat) ÷ fuel heat. It counts a kW of heat equal to a kW of power, so it flatters heat. A fairer test compares the fuel against separate production. Primary energy saving PES = 1 − F ÷ (Q/η_H + P/η_E), as in the EU's cogeneration rules. This book takes η_H = 83 % (the EU reference for a coal-fired steam boiler) and η_E = 38.3 %, THE PLANT's net efficiency, for grid power. The back-pressure plant saves 18.3 %, the extraction plant 10.8 %. Separate boiler plus grid burns 62.3 MW of fuel for the same demand.
What is a binary vapour cycle?
Water is a poor fluid at high temperature: to boil at 356.7 °C it needs 17.9 MPa, and it cannot boil at all above 374 °C. Mercury boils at 356.7 °C at atmospheric pressure (NIST). A binary cycle uses a high-temperature fluid in a topping cycle (historically mercury) whose condenser is the boiler of a steam bottoming cycle, so heat is added at a high mean temperature without huge pressures. Mercury is toxic, so such plants were abandoned. The idea lives on the other way round: organic Rankine cycles and the Kalina cycle (ammonia-water) use low-temperature heat that steam cannot.
A back-pressure turbine supplies a factory's 30 MW of process heat and makes 7.4 MW. The factory now needs 10 MW of power with the same heat. What happens?
A back-pressure turbine's steam flow is fixed by the heat demand (13.6 kg/s for 30 MW), and so is its power. Getting more power needs more steam through the turbine, and that extra steam has nowhere to go but a condenser: an extraction-condensing machine needs 2.63 kg/s extra for 10 MW. Raising the process pressure would make even less power.
Worked examples
Back-pressure turbine: power, heat-to-power ratio and EUF · Boiler steam 8.7 MPa, 510 °C (h1 = 3416 kJ/kg, isentropic h at 0.5 MPa = 2701.8); turbine 80 %, generator × mechanical 97 %; process takes 30 MW at 0.5 MPa and returns saturated condensate (h_f = 640.2, v_f = 0.001093 m³/kg); pump 85 %; boiler 83 %
- Exhaust h = 3416 − 0.80 × (3416 − 2701.8) = 2844.6 kJ/kg
- Process steam = 30,000/(2844.6 − 640.2) = 13.61 kg/s
- Generator output = 0.97 × 13.61 × 571.4 = 7543 kW; feed pump = 0.001093 × 8,200/0.85 = 10.54 kJ/kg = 143 kW
- Net power = 7.4 MW; heat-to-power = 30/7.4 = 4.05
- Fuel = 13.61 × (3416 − 650.7)/0.83 = 45.34 MW; EUF = (7.4 + 30)/45.34 = 82.5 %
Answer: 7.4 MW of power, heat-to-power 4.05, EUF 82.5 %
Fuel saved against a separate boiler and grid power · The same plant: 45.34 MW of fuel gives 30 MW of heat and 7.4 MW of power. Separate production: boiler 83 %, grid power at THE PLANT's net efficiency 38.3 %
- Separate fuel for the same outputs = 30/0.83 + 7.4/0.3827 = 36.14 + 19.33 = 55.48 MW
- PES = 1 − 45.34/55.48 = 18.3 %
- To meet a 10 MW demand the plant buys 2.6 MW: total fuel 45.34 + 2.6/0.3827 = 52.1 MW, against 62.3 MW for boiler plus grid
Answer: Cogeneration saves 18.3 % of the fuel; 10.1 MW less fuel for the factory's full demand
Sizing the condensing flow of an extraction turbine · Same steam, process 30 MW at 0.5 MPa (13.61 kg/s bled), power demand 10 MW net; condenser 10.3 kPa: isentropic h = 2128.9 kJ/kg, h_f = 194.2, v_f = 0.001011 m³/kg
- Condensing exhaust h = 3416 − 0.80 × (3416 − 2128.9) = 2386.4 kJ/kg
- Each kg/s of bled steam gives 554 kW; each kg/s condensed gives 999 kW at the generator
- Pumps: 10.54 kJ/kg (process return), 10.33 kJ/kg (condensate)
- 0.97 × [13.61 × 571.4 + ṁc × 1029.6] − (13.61 × 10.54 + ṁc × 10.33) = 10,000 kW → ṁc = 2.631 kg/s
- Condenser heat = 2.631 × (2386.4 − 194.2) = 5.77 MW; fuel = 55.52 MW; EUF = 40/55.52 = 72 %
Answer: 2.63 kg/s to the condenser; the plant now meets 10 MW but wastes 5.8 MW and its EUF falls to 72 %
Coal: proximate and ultimate analysis, calorific value and Indian coal grades
Which syllabus covers thisAU CME384 Unit I (fuel subsystem)VTU not in syllabusSPPU 402049 Unit 1 (classification of coal, beneficiation, selection)MU not in syllabusKTU PEMET631 Module 3 (fuel storage)
What separates peat, lignite, bituminous coal and anthracite?
Rank. Plant matter buried longer and deeper loses water and oxygen and gains carbon. Peat is the first stage: partly rotted plants, mostly water. The US EIA gives carbon contents of 25-35 % for lignite, 35-45 % for sub-bituminous coal, 45-86 % for bituminous coal and 86-97 % for anthracite. Higher rank means less moisture, less volatile matter and more heat per kilogram. India burns mostly high-ash non-coking bituminous coal in its power stations, plus lignite in 6,370 MW of units (CEA, 31 October 2026), mined in Tamil Nadu, Gujarat and Rajasthan.
What do the proximate and ultimate analyses tell a plant engineer, and why do the bases matter?
The proximate analysis splits coal by heating it in a lab: moisture, ash, volatile matter and fixed carbon. It is quick, so plants run it on every rake. The ultimate analysis gives the elements C, H, O, N and S, which the air and flue-gas sums need. Each can be quoted as received, air-dried, dry or dry-ash-free (daf). THE COAL as received is 10 % moisture, 38 % ash, 22 % volatile matter, 30 % fixed carbon. On the daf basis it is 42.3 % volatile matter and 76.9 % carbon, with a GCV of 30,596 kJ/kg. Move the ash slider: the daf bar never changes, because ash and water only dilute the burning part.
What is the difference between GCV and NCV, and how good is Dulong's formula?
The gross calorific value (GCV) counts the heat given back when the water in the flue gas condenses. A boiler stack never condenses it, so the net value (NCV) subtracts that latent heat: 2,442 kJ/kg for the water formed from hydrogen (9 kg per kg H) plus the coal's moisture. For THE COAL that is 0.334 kg of water per kg, so NCV = 15,094 kJ/kg (3,605 kcal/kg), 5.1 % below the GCV of 15,910. Dulong's estimate from the ultimate analysis gives 15,864 kJ/kg, within 0.3 %. Indian tariffs use GCV: CERC's energy charge takes the as-received GCV less 85 kcal/kg.
How are Indian coals graded, and what does a grade change cost the plant?
Coal India sells non-coking coal in 17 GCV bands of 300 kcal/kg, G1 (above 7,000) to G17 (2,201-2,500). THE COAL at 3,800 kcal/kg is G12 (3,701-4,000), priced at ₹896 per tonne at the pithead for power utilities in the December 2020 notification. At THE PLANT's gross heat rate of 8,842 kJ/kWh it burns 0.556 kg per kWh, 8,804 tonnes a day at full load. If the ash rises to 45 % with the same moisture, the GCV falls to 3,288 kcal/kg (G14) and the unit needs 10,173 t/day, 15.6 % more coal, wagons and crushing for the same megawatts.
Why is Indian coal so high in ash, and does washing help?
Most Indian coal is Gondwana coal of drift origin: plant debris was carried and laid down with mud and sand, so the mineral matter is mixed through the coal itself and is hard to wash out (as reported in the Journal of Mines, Metals and Fuels). A 2014 rule asked plants 500 km or more from the mine to use coal with at most 34 % ash; the ministry removed it in May 2020 (as reported by CSE). In this model, washing THE COAL from 38 % to 30 % ash lifts the GCV to 4,385 kcal/kg and cuts the coal burnt by 13.3 %. Imported coal at NTPC ran 5,700-6,300 kcal/kg against 2,900-4,200 for domestic coal (CAG, 2016).
THE COAL's ash rises from 38 % to 45 % (moisture stays 10 %). How much more coal does THE PLANT burn per day?
Ash and water only dilute the burning part. The daf fraction falls from 52 % to 45 %, so the GCV falls by the same ratio, from 3,800 to 3,288 kcal/kg, and the coal needed rises by 52/45 = 1.156: 8,804 → 10,173 t/day, 15.6 % more (boiler efficiency held at 87 %).
Worked examples
THE COAL on the air-dried, dry and dry-ash-free bases · As received: moisture 10 %, ash 38 %, volatile matter 22 %, fixed carbon 30 %, GCV 15,910 kJ/kg. Air-dried moisture 5 % (assumed).
- Air-dried factor = (100 − 5)/(100 − 10) = 1.0556: ash 40.1 %, VM 23.2 %, FC 31.7 %, GCV 16,794 kJ/kg.
- Dry factor = 100/(100 − 10) = 1.1111: ash 42.2 %, VM 24.4 %, FC 33.3 %.
- Dry GCV = 15,910 × 1.1111 = 17,678 kJ/kg.
- Dry-ash-free factor = 100/(100 − 10 − 38) = 1.9231: VM 42.3 %, FC 57.7 %.
- daf GCV = 15,910 × 1.9231 = 30,596 kJ/kg (7,308 kcal/kg).
Answer: Dry: ash 42.2 %, GCV 17,678 kJ/kg. daf: VM 42.3 %, FC 57.7 %, GCV 30,596 kJ/kg.
Dulong GCV and the NCV of THE COAL · Ultimate analysis as fired: C 40 %, H 2.6 %, O 8.1 %, N 0.8 %, S 0.5 %, moisture 10 %, ash 38 %. Measured GCV 15,910 kJ/kg.
- Dulong: 33,820 × 0.40 = 13,528; 144,200 × (0.026 − 0.081/8) = 2,289; 9,400 × 0.005 = 47.
- GCV ≈ 15,864 kJ/kg, 0.29 % below the measured 15,910.
- Water in the flue gas per kg coal = 9 × 0.026 + 0.10 = 0.334 kg.
- NCV = 15,910 − 2,442 × 0.334 = 15,094 kJ/kg = 3,605 kcal/kg.
Answer: Dulong 15,864 kJ/kg (−0.3 %); NCV 15,094 kJ/kg, 5.1 % below the GCV.
Coal per day and grade for a 45 % ash coal · Same daf coal as THE COAL (daf GCV 30,596 kJ/kg), ash 45 %, moisture 10 %; THE PLANT 660 MW gross, gross heat rate 8,842 kJ/kWh.
- daf fraction = 1 − 0.45 − 0.10 = 0.45; GCV = 0.45 × 30,596 = 13,768 kJ/kg = 3,288 kcal/kg.
- Band 3,101-3,400 kcal/kg: grade G14.
- Coal per kWh = 8,842/13,768 = 0.642 kg/kWh.
- Per day = 0.6422 × 660,000 kWh/h × 24 h = 10,173 t/day.
- Ash per day = 0.45 × 10,173 = 4,578 t, against 3,345 t for THE COAL.
Answer: G14, 10,173 t/day of coal (+15.6 %) and 4,578 t/day of ash.
Coal and ash handling: from the mine to the bunker and from the furnace to the ash pond
Which syllabus covers thisAU CME384 Unit I (fuel and ash handling)VTU BME515D Module 1 (coal and ash handling)SPPU 402049 Unit 1 (in-plant coal handling), Unit 2 (ash handling)MU not in syllabusKTU PEMET631 Module 3 (fuel handling, dust and ash handling)
What happens to coal between the railway siding and the burner?
Rakes arrive at the plant siding. A wagon tippler turns each open BOXN wagon upside down over a hopper (bottom-opening wagons dump into a track hopper instead). Crushers cut the lumps down, conveyors carry the coal to the stockyard, where stacker-reclaimers build and dig the piles, or straight to the boiler bunkers. Feeders meter coal from the bunkers into the mills. At 75 % load THE PLANT burns 6,603 t a day: 1.94 rakes of 58 BOXN wagons × 58.81 t = 3,411 t (RDSO figures as reported by IRFCA).
How big must the conveyors, stockyard and bunkers be?
Size the conveyors on full load, not the average: THE PLANT at 660 MW needs 8,804 t a day. Moved in 16 working hours, that is 550 t/h per stream, with a second stream on standby. A 20-day stock at 75 % load is 132,053 t, about 2.8 ha of 10 m pile in this model. Eight 600 t bunkers (assumed) hold 13.1 hours at full load, so a conveyor breakdown does not trip the unit. Pick the imported coal: fewer tonnes for the same heat, so every number shrinks.
How is ash taken out of a pulverised-coal boiler?
About 80 % of the ash leaves with the flue gas as fly ash; 20 % falls to the furnace bottom (the split used in this book). Bottom ash drops into a water-filled hopper, is crushed and sluiced by water jets to a slurry sump, then pumped to the ash pond, either as lean slurry or as high-concentration slurry (HCSD) that needs far less water. Fly ash is caught in the electrostatic precipitator hoppers and blown pneumatically, by vacuum or pressure, to dry silos for trucks and cement plants. At 75 % load THE PLANT makes 2,017 t of fly ash and 528 t of bottom ash a day.
What does the law say about fly ash?
MoEFCC notification S.O. 5481(E) of 31 December 2021 makes every coal or lignite plant use 100 % of the fly and bottom ash it makes. Utilisation may never fall below 80 % in any year and must average 100 % over a three-year cycle. Unused ash costs ₹1,000 per tonne in environmental compensation, and a new emergency ash pond is limited to 0.1 ha per MW, 66 ha for THE PLANT. In 2024-25 India's plants generated 340.11 Mt of ash and used 332.63 Mt, 97.8 % (PIB): 32 % in roads and flyovers, 27 % in cement and 14 % in bricks and tiles.
How fast does an ash pond fill?
Ash residue per day at 75 % load is 2,546 t for THE COAL, including the unburnt carbon. With no utilisation, settled at 1.0 t/m³ in a 10 m deep pond (assumed), that is 9.3 ha of new pond every year, and the 66 ha emergency pond is full in 7.1 years. At 98 % utilisation it is 0.19 ha a year. Imported coal with 10 % ash cuts the residue to 424 t/day, 83 % less. That is why a high-ash coal plant is as much an ash business as a power business.
THE PLANT switches from THE COAL (3,800 kcal/kg, 38 % ash) to imported coal (6,000 kcal/kg, 10 % ash). By how much does its daily ash fall?
Two effects multiply: fewer tonnes for the same heat (3,800/6,000) and less ash per tonne (10/38). 0.633 × 0.263 = 0.167, so the residue falls from 2,546 to 424 t/day at 75 % load, 83 % less.
Worked examples
Rakes and coal stock for THE PLANT · 660 MW gross, gross heat rate 8,842 kJ/kWh, THE COAL 15,910 kJ/kg, plant load factor 75 %, 20 days of stock, rake 58 wagons × 58.81 t.
- Coal at full load = 8,842 × 660,000/15,910 = 366,814 kg/h = 366.8 t/h.
- Average day at 75 % = 366.8 × 24 × 0.75 = 6,603 t.
- Rake = 58 × 58.81 = 3,411 t, so rakes per day = 6,603/3,411 = 1.94.
- Stock = 20 × 6,603 = 132,053 t, about 39 rakes.
- Pile area at 0.8 t/m³, 10 m high, 60 % effective = 132,053/(0.8 × 10 × 0.6) = 27,511 m² ≈ 2.75 ha.
Answer: 1.94 rakes a day (about 14 a week); 132,053 t stock on about 2.8 ha.
Ash per day and the ash pond · THE COAL (38 % ash) at 75 % load: 6,603 t/day. Fly : bottom = 80 : 20; unburnt carbon 0.5 % of fly ash, 5 % of bottom ash. Pond 10 m deep, 1.0 t/m³.
- Mineral ash = 0.38 × 6,603 = 2,509 t/day.
- Fly ash collected = 0.8 × 2,509/0.995 = 2,017 t; bottom ash = 0.2 × 2,509/0.95 = 528 t.
- Total residue = 2,546 t/day = 0.929 Mt a year.
- No utilisation: 929 thousand m³ a year ÷ 10 m = 9.29 ha a year.
- 66 ha emergency pond (0.1 ha/MW) lasts 66/9.29 = 7.1 years; at 98 % utilisation the pond grows 0.19 ha a year.
Answer: 2,546 t of ash a day; 9.3 ha/yr of pond if none is used, 0.19 ha/yr at 98 %.
Conveyor capacity and bunker hours · THE PLANT at full load (660 MW, THE COAL); conveyors work 14 h a day; 8 bunkers × 600 t (assumed).
- Full-load coal = 366.8 t/h, 8,804 t/day.
- Conveyor stream = 8,804/14 = 629 t/h; install two streams, one standby.
- Bunker storage = 8 × 600 = 4,800 t.
- Bunker hours = 4,800/366.8 = 13.1 h at full load.
Answer: 2 × 629 t/h conveyors; bunkers last 13.1 h at full load.
Firing systems: stokers, pulverised coal, mills and burners, and fluidised bed combustion
Which syllabus covers thisAU CME384 Unit I (FBC boilers)VTU not in syllabusSPPU 402049 Unit 1 (pulverized fuel handling, FBC systems)MU not in syllabusKTU PEMET631 Module 3 (burning systems)
Why do big boilers grind coal to powder instead of burning it on a grate?
A stoker burns lump coal on a grate: a chain-grate stoker carries a bed of coal slowly through the furnace on a moving chain, while a spreader stoker flings coal onto the grate so fines burn in the air above it. Grates suit small industrial boilers. THE PLANT burns 101.9 kg of coal every second; no grate can spread that. Ground to powder, coal burns in suspension like a gas flame, the load follows within minutes, and nearly all the carbon burns out (this book assumes only 0.5 % carbon left in the fly ash).
How do mills and burners prepare and fire pulverised coal?
Bowl (vertical roller) mills crush coal between rollers and a turning bowl; tube (ball) mills tumble it with steel balls. Hot primary air dries the coal and carries the powder through a classifier, which returns coarse particles; a common target is about 70 % through a 200-mesh (75 µm) sieve (typical, assumed). If THE PLANT runs 7 of 8 mills, each grinds 52.4 t/h. In tangential firing, burners in the four furnace corners aim at an imaginary circle, so the flames spin into one fireball that mixes air and coal well.
How much air does a kilogram of coal need?
Carbon needs 32/12 kg of oxygen per kg, hydrogen 8 kg and sulphur 1 kg, less the oxygen already in the coal. Air is about 23 % oxygen by mass, which gives the formula below. For THE COAL it gives 5.169 kg of air per kg; the book's combustion kernel, working in moles, gets 5.167. Real burners need excess air to burn out the carbon: at 20 % excess THE COAL takes 6.2 kg/kg, so THE PLANT's fans move 632 kg/s of air, more than six times the coal flow.
What is a fluidised bed, and when does it bubble, churn or circulate?
Blow air up through a bed of sand-sized particles. Below the minimum fluidisation velocity Umf the bed stays packed; above it the drag carries the bed's weight and it behaves like a boiling liquid. For 0.3 mm particles at 850 °C, Wen and Yu's correlation gives Umf = 0.031 m/s. Faster gas makes bubbles, then a turbulent bed above about 2.3 m/s, then fast fluidisation above about 7.5 m/s, where solids leave the top and a cyclone sends them back: a circulating fluidised bed (CFB). CFB boiler bottom beds run at up to about 6 m/s (Leckner).
Why do fluidised bed boilers suit high-ash coal and lignite?
The bed burns at about 850 °C, below the temperature at which ash melts, so ash does not slag on the tubes and little nitrogen oxide forms. Limestone added to the bed captures sulphur: CaCO3 → CaO + CO2, then CaO + SO2 + ½O2 → CaSO4. Bubbling beds (AFBC) suit small units, CFBC units reach hundreds of megawatts, and pressurised beds (PFBC) also drive a gas turbine. An assumed 250 MW CFBC unit burning a 3 % sulphur lignite at Ca/S 2 uses 1,000 t of limestone a day. CERC allows lignite fluidised-bed boilers a minimum efficiency of 80 % against 76 % for pulverised firing.
A bed of 1 mm sand at 850 °C bubbles gently at 2 m/s. The operator doubles the air to 4 m/s. What happens?
For 1 mm particles Umf = 0.34 m/s, the turbulent onset is about 3.7 m/s and significant entrainment starts near 13.8 m/s. 4 m/s lies between the last two: a turbulent bed, still well below the 8.9 m/s terminal velocity of a single grain.
Worked examples
Minimum fluidisation velocity of a 0.5 mm bed at 850 °C · Sand-like particles 0.5 mm, 2,600 kg/m³; air at 850 °C and 1 atm: ρ = 0.3143 kg/m³ (ideal gas), µ = 44.49 µPa·s.
- Archimedes number Ar = d³ ρ (ρp − ρ) g/µ² = (5×10⁻⁴)³ × 0.3143 × 2,599.7 × 9.807/(44.49×10⁻⁶)² = 506.
- Wen and Yu: Re_mf = √(33.7² + 0.0408 × 506) − 33.7 = 0.3049.
- Umf = Re_mf µ/(ρ d) = 0.3049 × 44.49×10⁻⁶/(0.3143 × 5×10⁻⁴) = 0.0863 m/s.
- Terminal velocity of one grain (Schiller-Naumann drag, by iteration) = 4.1 m/s, 47 times Umf: the bed can run across a wide speed range without blowing away.
Answer: Umf ≈ 0.086 m/s; Ut ≈ 4.1 m/s.
Air for THE COAL and for THE PLANT · THE COAL: C 40 %, H 2.6 %, O 8.1 %, S 0.5 %; 20 % excess air; coal 366.8 t/h at full load.
- Theoretical air = 11.5 × 0.40 + 34.5 × (0.026 − 0.081/8) + 4.3 × 0.005 = 4.6 + 0.5477 + 0.0215 = 5.169 kg/kg.
- The mole-based kernel gives 5.167 kg/kg (air 20.95 % O2 by volume); the two agree within 0.03 %.
- Actual air at 20 % excess = 1.2 × 5.167 = 6.201 kg/kg.
- Coal = 366.8/3.6 = 101.9 kg/s, so air = 101.9 × 6.201 = 632 kg/s.
Answer: 5.17 kg/kg theoretical, 6.2 kg/kg actual; 632 kg/s for THE PLANT.
Limestone for a lignite-fired CFBC unit · Assumed 250 MW CFBC unit, gross heat rate 2,500 kcal/kWh (CEA default for 200-250 MW units); lignite C 33 %, H 2.5 %, O 11 %, N 0.5 %, S 3 %, ash 10 %, moisture 40 %; Ca/S = 2; limestone 90 % CaCO3.
- Dulong GCV = 33,820 × 0.33 + 144,200 × (0.025 − 0.11/8) + 9,400 × 0.03 = 13,065 kJ/kg (3,120 kcal/kg).
- Lignite per day = 2,500 × 4.1868 × 250,000 × 24/13,065 = 4,806,944 kg = 4,807 t.
- Sulphur = 30 kg/t = 30/32.06 = 0.936 kmol/t; CaCO3 at Ca/S 2 = 2 × 0.936 × 100.09 = 187.3 kg/t.
- Limestone = 187.3/0.9 = 208.1 kg/t, so 208.1 × 4,807/1,000 = 1,000 t/day.
- With the assumed capture curve, Ca/S 2 removes 90 % of 59.9 kg SO2 per tonne of lignite.
Answer: About 1,000 t of limestone a day (208 kg per tonne of lignite) for 90 % SO2 capture.
High-pressure boilers: natural and forced circulation, once-through and supercritical boilers
Which syllabus covers thisAU CME384 Unit I (super critical boilers)VTU BME515D Module 1 (forced circulation, LaMont, Benson, Velox, Loeffler, Schmidt)SPPU 402049 Unit 1 (high pressure boilers)MU MEC602 Module 1 (high pressure boilers)KTU PEMET631 Module 1 (high pressure boilers)
Why are there so many high-pressure boiler designs?
Each one answers the same problem: water and steam grow alike as pressure rises, so density can no longer drive the flow. At 4 MPa saturated water is 39.7 times denser than steam; at 18 MPa only 4.1 times. La Mont boilers add a pump to the drum circuit. Benson boilers drop the drum: water is pumped through the tubes once and leaves as steam. Loeffler boilers evaporate water by bubbling superheated steam through it, so no salts deposit in heated tubes. Schmidt-Hartmann boilers heat a sealed primary circuit that boils the feed water. Velox boilers burn under pressure with fast gas to raise heat transfer.
What drives water round a natural-circulation boiler, and why does it fail near 22 MPa?
The downcomer is full of water; the furnace-wall risers hold a lighter steam-water mixture. The weight difference over the riser height H pushes water down and mixture up. With uniform heating and no slip, the riser's mean density has the closed form below. At 16 MPa, 40 m and circulation ratio 5, ρl = 584.8 kg/m³, the riser averages 418 kg/m³ and the head is 65.3 kPa. At 20 MPa it is 29 kPa, and at 22.064 MPa, where water and steam become one phase, it is zero.
What is the circulation ratio, and why not just boil all the water in one pass?
Circulation ratio CR = water circulated per kg of steam made = 1/x, where x is the dryness at the riser exit. CR 5 means each kilogram passes the furnace five times before it leaves as steam. A wetter mixture keeps a liquid film on the tube wall; if the wall dries out under high heat flux, the tube metal overheats. More water costs head: at 16 MPa and 40 m, CR 5 gives 65.3 kPa but CR 10 only 39.6 kPa. Once-through boilers use ribbed tubes in the burner zone to avoid departure from nucleate boiling.
What do the drum and the water walls do?
Water walls are vertical tubes welded side by side with fins into gas-tight membrane panels that form the furnace. They absorb the flame's radiation and are the risers of the circulation loop. The drum on top receives the mixture, and cyclone separators and scrubbers inside it strip water from the steam before it goes to the superheater. The drum also stores water to ride through load changes, receives the feed water and is where blowdown removes dissolved solids. At 16 MPa the drum holds saturated water and steam at 347.4 °C.
Why are India's new coal units supercritical once-through boilers?
Above 22.064 MPa water turns to steam with no boiling and no drum is possible: feed pumps push water through the furnace tubes once (the Benson principle). THE PLANT runs at 24.2 MPa and 565 °C. Many designs wind the lower furnace tubes in a spiral, so each tube passes every wall and sees the same average heat, with vertical tubes above. With no thick drum the boiler can slide its pressure with load. The gain is efficiency: CERC caps the design turbine-cycle heat rate at 1,850 kcal/kWh for 247 kg/cm², 565/593 °C units against 1,935 for 170 kg/cm² subcritical units, 4.4 % lower.
A drum boiler's circulation head is 65 kPa at 16 MPa (40 m risers, circulation ratio 5). Raise the drum pressure to 20 MPa with the same risers and ratio. The head becomes about:
Saturated water gets lighter and steam heavier as pressure rises: ρl/ρv falls from 5.45 to 2.88. The head drops to 29 kPa, 55 % less, which is why boilers this close to the critical pressure add circulating pumps or go once-through.
Worked examples
Natural circulation head at 10 MPa · Drum pressure 10 MPa; riser height 35 m; circulation ratio 6; quality rises uniformly from 0 to the exit; homogeneous mixture (no slip). Saturated densities from IAPWS SR1-86.
- At 10 MPa: ρl = 688.6 kg/m³, ρv = 55.47 kg/m³; vf = 0.001452, vfg = 0.01658 m³/kg.
- Exit dryness x = 1/6 = 0.1667; x vfg/vf = 1.902.
- Mean riser density = ln(1 + 1.902)/(0.1667 × 0.01658) = 385.7 kg/m³.
- Δp = (688.6 − 385.7) × 9.807 × 35 = 103,973 Pa.
Answer: Driving head ≈ 104 kPa.
The same loop at 18 MPa · As above but drum pressure 18 MPa.
- At 18 MPa: ρl = 543.4 kg/m³, ρv = 133.3 kg/m³; ρl/ρv = 4.08 (it was 12.41 at 10 MPa).
- Mean riser density = 438.7 kg/m³.
- Δp = (543.4 − 438.7) × 9.807 × 35 = 35,961 Pa.
- Ratio to the 10 MPa head = 0.346: 65 % of the head is gone.
Answer: Head ≈ 36 kPa, about 35 % of the 10 MPa value.
Water circulated in a drum boiler · Assumed drum boiler making 1,600 t/h of steam at 16 MPa with circulation ratio 5; four downcomers of 0.5 m bore.
- Water circulated = 5 × 1,600 = 8,000 t/h = 2,222 kg/s.
- Riser exit dryness = 1/5 = 0.2.
- Downcomer flow area = 4 × π × 0.5²/4 = 0.785 m².
- Downcomer water speed = 2,222/(584.8 × 0.785) = 4.84 m/s.
Answer: 8,000 t/h circulates; the downcomers run at about 4.8 m/s.
Boiler efficiency by the direct and indirect (heat loss) methods
Which syllabus covers thisAU CME357 Unit I (boiler efficiency)VTU not in syllabusSPPU 402049 Unit 1 (energy conservation in boilers)MU not in syllabusKTU not in syllabus
What are the direct and indirect methods of finding boiler efficiency?
The direct method divides the heat put into the steam by the heat in the coal burnt: η = steam flow × (h_steam − h_feed) / (coal flow × GCV). For THE PLANT that is 1,410 MW to steam ÷ (101.9 kg/s × 15,910 kJ/kg) = 87 %. The indirect method subtracts every measured loss from 100. BEE prefers the indirect method on large boilers for two reasons: coal flow is hard to weigh accurately, and a 1 % error in a measured quantity moves the direct answer by about 0.88 points but the indirect answer by only 0.12. It also tells you where the heat went.
Which losses make up the heat-loss method, and how big is each for the book's coal?
At 140 °C exit gas, 30 °C air and 20 % excess air, THE COAL loses: dry flue gas 4.32 % (the hot gas itself), hydrogen 3.9 % (water formed from H2 leaves as vapour, latent heat and all), fuel moisture 1.67 %, moisture in air 0.17 %, unburnt carbon in fly ash 0.32 % and in bottom ash 0.85 %, and radiation plus unaccounted 1 % (assumed; BEE gives 0.4-1 % for power-station boilers). Total 12.24 %, so η = 87.76 %, 0.76 points above the 87 % the book's kernel assumes. The two water losses together (5.57 %) outweigh the dry gas.
Why are exit gas temperature and excess air the operator's two main knobs?
They set the dry flue gas loss, the biggest one. Every 10 °C of extra exit gas costs THE PLANT 0.45 efficiency points; at 170 °C the boiler falls to 86.42 %. Every extra 1 % of O2 in the flue gas means more air heated for nothing: 0.26 points; at 6 % O2 (excess air 39 %) η is 87.07 %. Too little air is worse: CO and unburnt carbon appear. Raising fly-ash carbon from 0.5 to 3 % alone drops η to 86.09 %. So operators trim air to the lowest O2 that keeps CO and carbon low, and keep the air preheater clean.
If cooler exit gas saves coal, why not cool it to 80 °C?
Because the flue gas carries sulphur trioxide and water vapour, and below the acid dew point sulphuric acid condenses on the coldest metal. For THE COAL that dew point is about 138 °C (chapter 11 works it out). THE PLANT leaves its gas at 140 °C, just above it, and accepts the loss. The prize is real: cooling 140 °C gas by another 20 °C would save about 0.9 points, roughly 88 tonnes of coal a day for THE PLANT, if the cold end could survive it.
Why does the same boiler have two efficiencies, one on GCV and one on NCV?
GCV (gross calorific value) counts the latent heat of the water vapour formed by burning; NCV does not, because that heat always leaves up the stack. THE COAL has GCV 15,910 and NCV 15,094 kJ/kg, so the same boiler is 87.8 % on GCV but 92.5 % on NCV. India's CERC rules and BEE use GCV: CERC's minimum design boiler efficiency for Indian coal is 86 %, and NTPC filed 86.19 % for Lara and 85.01 % for Darlipali. The gas turbine figures in chapter 16 use the fuel's lower (net) value, so always ask which basis a number is on.
THE PLANT's exit gas is cooled from 140 °C to 120 °C. Boiler efficiency rises by about…
Dry gas, hydrogen, moisture and humidity losses all scale with (Tf − Ta): 0.448 points per 10 °C, so 20 °C gives about 0.9 points, worth roughly 88 t of coal a day for THE PLANT.
Worked examples
Boiler efficiency by the heat-loss method for an original high-ash coal · Coal (as fired): C 45 %, H 3 %, O 8 %, N 1 %, S 0.6 %, ash 32 %, moisture 10.4 %; GCV 4,300 kcal/kg; flue gas O2 4.5 %, 160 °C; air 32 °C with 0.020 kg water/kg dry air; ash 80 % fly (1 % carbon), 20 % bottom (4 % carbon); carbon 8,078 kcal/kg; radiation + unaccounted 0.8 % (assumed)
- Theoretical air (BEE) = [11.6 × 45 + 34.8 × (3 − 8/8) + 4.35 × 0.6]/100 = 5.942 kg/kg
- Excess air ≈ O2/(21 − O2) = 4.5/16.5 = 27.3 %; actual air = 5.942 × 1.273 = 7.563 kg/kg
- Dry flue gas = 0.45 × 44/12 + 0.006 × 64/32 + 0.01 + 0.77 × 7.563 + 0.23 × (7.563 − 5.942) = 7.87 kg/kg
- L1 dry gas = 7.87 × 0.23 × (160 − 32)/4,300 × 100 = 5.39 %
- L2 hydrogen = 9 × 0.03 × (584 + 0.45 × 128)/4,300 × 100 = 4.03 %; L3 moisture = 0.104 × 641.6/4,300 × 100 = 1.55 %
- L4 humidity = 7.563 × 0.020 × 0.45 × 128/4,300 × 100 = 0.2 %
- Unburnt: fly ash 0.256/0.99 kg holds 2.59 g carbon → 0.49 %; bottom ash 0.064/0.96 kg holds 2.67 g → 0.5 %
- Sum with 0.8 % radiation = 12.96 %
Answer: η ≈ 87 % (GCV basis); the dry flue gas and hydrogen losses are 73 % of all losses
Direct method for an industrial boiler, and why a weighing error matters · 20 t/h of steam at 4 MPa, 400 °C; feed water 105 °C; coal 3.6 t/h of GCV 4,000 kcal/kg; steam tables (IF97): h = 3,214.4 kJ/kg, feed h = 443.1 kJ/kg
- Heat to steam = 20,000 × (3,214.4 − 443.1) = 55.43 GJ/h
- Heat in coal = 3,600 × 4,000 × 4.1868 = 60.29 GJ/h
- η = 55.43/60.29 = 91.9 %
- If the coal weigher reads 2 % low or high, η comes out 93.8 % or 90.1 %: a 3.7-point spread from one meter
- The heat-loss method needs only a flue gas analyser, two thermometers, a coal analysis and an ash carbon test
Answer: η ≈ 91.9 %, but a ±2 % coal weighing error moves it by ±1.8 points
What a fouled air preheater costs THE PLANT · THE PLANT: 1,410 MW to steam, THE COAL (GCV 15,910 kJ/kg); exit gas rises from 140 °C to 170 °C, everything else at the book defaults
- At 140 °C: losses 12.24 %, η = 87.76 %, coal = 1,410,355/(0.8776 × 15,910) = 101 kg/s
- At 170 °C: dry gas loss 5.5 %, hydrogen 3.98 %, moisture 1.7 %; η = 86.42 %
- Coal at 170 °C = 102.6 kg/s
- Extra coal = 136 t/day for the same steam
Answer: η falls 1.34 points and THE PLANT burns about 136 t more coal a day
Draught: natural draught and chimney height, forced, induced and balanced draught and fan power
Which syllabus covers thisAU CME384 Unit I (draught system)VTU not in syllabusSPPU not in syllabusMU not in syllabusKTU PEMET631 Module 3 (chimney draught)
How does a chimney create draught, and how big is it?
Hot flue gas is lighter than the outside air, so a column of it is pushed up, like a cork in water. The pressure difference at the chimney base is the draught: Δp = g H (ρ_air − ρ_gas). With densities from the ideal gas law (air 28.97 kg/kmol; THE COAL's wet flue gas 29.43 kg/kmol), air at 30 °C is 1.164 kg/m³ and gas at 140 °C is 0.868 kg/m³. A 275 m chimney then gives 799 Pa, or 81.5 mm of water column (mmWC, the plant's unit: 1 mmWC = 9.81 Pa). On a 45 °C summer afternoon it drops to 66.4 mmWC.
At what gas temperature does a chimney pass the most gas?
Hotter gas gives more draught but is less dense, so each cubic metre carries less mass. With no friction the gas speed is √(2gH′), where H′ = H(ρa/ρg − 1) is the height of a hot-gas column equal to the draught, and the mass flow per m² is ρg√(2gH′). Setting its derivative to zero gives Tg = 2 Ta Mg/Ma: for 30 °C air and THE COAL's gas, 343 °C, where H′ equals H. At 140 °C the same chimney passes 87 % of that maximum. Nobody runs a stack at 343 °C: that heat is worth far more in the air preheater, so fans supply the rest.
What are forced, induced and balanced draught?
Forced draught (FD) fans push air into the furnace, so the furnace runs above atmospheric pressure and leaks hot gas outward. Induced draught (ID) fans suck gas out at the back end, so the furnace runs below atmospheric and leaks cold air in. Large coal boilers use both, balanced draught, with the furnace held a few mmWC below atmospheric so no ash-laden gas escapes. For THE PLANT the ID fans move 816 m³/s of gas at 140 °C against an assumed 4.0 kPa: 4.08 MW at 80 % fan efficiency. The FD fans move 554 m³/s of air: 1.73 MW. Together 0.88 % of gross output.
If fans do the work, why are chimneys still 275 m tall?
For dispersion, not draught. A tall stack releases SO2 and dust high enough to dilute before reaching the ground. India's Environment (Protection) Rules, 1986 (Schedule I) fix 275 m for units of 500 MW and above, 220 m for 200-500 MW, and H = 14 Q^0.3 (Q = SO2 in kg/h) below that. THE PLANT emits about 3,665 kg/h of SO2 without FGD; the formula would give 164 m, so the 275 m rule governs. After a wet FGD the gas leaves at about 55 °C (assumed) and the same chimney's draught falls to 19.6 mmWC: the ID fans carry it.
How are draught fans built and controlled?
Big FD and ID fans are axial fans with variable-pitch blades or centrifugal fans with inlet vanes or variable-speed drives. The fan laws decide the control: flow ∝ speed, pressure ∝ speed², power ∝ speed³. At 70 % flow a speed-controlled fan needs about 34 % of its full-load power, while a fan throttled by a damper still burns most of it. ID fans handle hot, dusty gas after the ESP, so their blades erode, and every draught fan is bought with margins on flow and pressure. Primary air fans, a third set, carry coal from the mills to the burners.
Ambient air warms from 30 °C to 45 °C. The 275 m chimney's natural draught with 140 °C gas…
Draught depends on the density difference. Warmer air is lighter (1.109 vs 1.164 kg/m³) while the gas stays at 0.868, so the draught falls from 81.5 to 66.4 mmWC. Summer afternoons are when ID fans run hardest.
Worked examples
Chimney height for a required draught · A boiler needs 18 mmWC of natural draught; flue gas 200 °C with molar mass 30 kg/kmol; air 35 °C; 1 atm; allow 20 % of the theoretical draught for friction and exit velocity (assumed)
- ρ_air = 101,325 × 28.97/(8,314 × 308.15) = 1.145 kg/m³; ρ_gas = 101,325 × 30/(8,314 × 473.15) = 0.773 kg/m³
- Δρ = 0.373 kg/m³; 18 mmWC = 176.5 Pa
- H = Δp/(g Δρ) = 176.5/(9.81 × 0.373) = 48.3 m
- Check with the textbook form 353 H (1/Ta − 1/Tg), which assumes gas = air: H = 45.1 m
- With 20 % losses: H = 48.3/0.8 = 60.4 m
Answer: About 60 m (the molar mass of the gas matters: the air-only formula gives 56 m)
Maximum discharge of a 60 m chimney · Air at 27 °C; treat gas and air as having the same molar mass; no friction
- Best gas temperature Tg = 2 Ta = 2 × 300.15 = 600.3 K = 327 °C
- ρ_air = 1.176, ρ_gas = 0.588 kg/m³; draught = 9.81 × 60 × (1.176 − 0.588) = 346 Pa = 35.3 mmWC
- Hot-gas column H′ = 60 × (1.176/0.588 − 1) = 60 m, equal to H as the theory says
- Gas speed √(2 × 9.81 × 60) = 34.3 m/s; mass flux = 20.17 kg/(s·m²)
- At 150 °C the flux would be 18.32 kg/(s·m²), 91 % of the maximum
Answer: 327 °C gives the most flow, 20.17 kg/(s·m²); the curve is flat near the top, so cooler gas loses little
ID and FD fan power for THE PLANT · THE COAL at 20 % excess air: wet flue gas 5.296 Nm³/kg, air 6.201 kg/kg (humidity 0.0214 kg/kg); coal 101.9 kg/s; gas at the ID fan 140 °C, air 30 °C; Δp ID 4.0 kPa, FD 2.5 kPa; fan efficiency 0.80 (assumed)
- Gas: 5.296 × 101.9 = 540 Nm³/s; at 140 °C × 413.15/273.15 = 816 m³/s
- ID power = 816 × 4.0/0.80 = 4,081 kW
- Air: 6.201 × 1.0214 × 101.9 = 645 kg/s; ρ at 30 °C = 1.164 kg/m³ → 554 m³/s
- FD power = 554 × 2.5/0.80 = 1,732 kW
- At 70 % load with speed control, power ∝ flow³: ID about 1,400 kW
Answer: ID 4.08 MW and FD 1.73 MW, 0.88 % of the 660 MW gross
Economiser, air preheater and superheater: heat recovery and the acid dew point
Which syllabus covers thisAU CME357 Units IV-V (economiser, air preheaters, acid dew point)VTU BME515D Module 1 (superheaters, economizers, air preheaters)SPPU 402049 Unit 1 (energy conservation in boilers)MU not in syllabusKTU PEMET631 Module 1 (boiler accessories)
What does the economiser do?
It is the last water-heating surface in the gas path: a bank of finned or bare tubes that heats feedwater with gas the superheaters and reheater could no longer use. In the book's assumed design, gas cools from 560 °C to 360 °C across it, giving 154.5 MW to THE PLANT's 525.7 kg/s of feedwater: 294 kJ/kg, raising it from 290 °C to about 342 °C at 24.2 MPa. That water stays liquid (a non-steaming economiser). In drum boilers a steaming economiser lets a little steam form at its outlet. Without it, the gas would reach the air preheater 200 °C hotter.
How are superheaters and reheaters arranged, and how is steam temperature held?
Radiant and platen superheaters hang in the furnace and absorb flame radiation; convective superheaters and reheaters sit in the gas pass behind. In the book's design the gas falls from 1,100 °C at the furnace exit to 800 °C after the superheaters and 560 °C after the reheater. Radiant surfaces pick up relatively more heat at low load and convective ones at high load, so mixing the two flattens the steam temperature curve. The fine trim is spray attemperation: water injected into the steam. Cooling THE PLANT's 24.2 MPa steam from 575 °C to 565 °C needs spray water of 1.45 % of the steam flow, taken from 290 °C feedwater.
What do air preheaters gain, and how do tubular and regenerative types differ?
The air preheater (APH) takes the last useful heat from the gas into the combustion air. For THE PLANT it cools 709 kg/s of gas from 360 °C to 140 °C and heats 645 kg/s of air from 30 °C to 288 °C: 170 MW, about 12 % of the heat to steam. Tubular heaters are steel tubes, leak-tight but huge. Regenerative (Ljungström) heaters rotate a drum of metal plates through the gas, then the air (bi-sector; tri-sector splits primary and secondary air): compact, but air leaks across the seals. With 8 % leakage the thermometer reads 140 °C while the gas really left the heater at 148 °C: η 87.39 % instead of 87.76 %.
What sets the acid dew point of flue gas?
A small part of the SO2 from the coal's sulphur oxidises to SO3 (1.5 % assumed here), which joins water vapour as sulphuric acid. It condenses far above the water dew point. Verhoff and Banchero's correlation uses the two partial pressures (mmHg): THE COAL's gas has 10.9 % water vapour and 9.9 ppm SO3, giving 138 °C (Okkes's correlation gives 134 °C). A coal with 2 % sulphur pushes it to 152 °C; 3 % conversion to 145 °C. THE COAL's assumed 0.5 % sulphur keeps it modest.
Why does the cold end of the air preheater corrode, and how do plants live with it?
The metal temperature is roughly the average of the gas and air beside it. At the cold end, 140 °C gas meets 30 °C air, so the plates sit near 85 °C, well below the 138 °C acid dew point, even though the gas itself is above it. Acid condenses, corrodes the plates and glues fly ash into blockages. Plants use enamelled or corrosion-resistant cold-end plates, soot blowing, and steam coil air preheaters that warm the incoming air in winter. Cooling the exit gas 20 °C further would gain 0.9 points, about 88 t of coal a day, which is why the trade-off is argued over in every design.
Two air preheaters both read 140 °C at the exit. One is tubular; the other is a Ljungström with 8 % air leakage. Which boiler is more efficient?
In the Ljungström, cold leak air mixes into the gas after the heater and pulls the reading down. Corrected, the gas left the heater at 148.2 °C, so the boiler is 0.37 points less efficient (87.39 % vs 87.76 %), and the ID fan moves 8 % more gas.
Worked examples
Acid dew point by Verhoff and Banchero · Flue gas at 1 atm with 9 % water vapour and 15 ppm SO3 (by volume); pressures in mmHg
- p_w = 0.09 × 760 = 68.4 mmHg; p_s = 15 × 10⁻⁶ × 760 = 0.0114 mmHg
- ln p_w = 4.2254; ln p_s = −4.4741
- 1000/T = 2.276 − 0.0294 × 4.2254 − 0.0858 × (−4.4741) + 0.0062 × 4.2254 × (−4.4741) = 2.4184
- T = 1000/2.4184 = 413.5 K = 140.3 °C
- Okkes's correlation (pressures in atm) gives 135.5 °C; Verhoff-Banchero tends to read high at high moisture
Answer: About 140 °C: keep the exit gas and, ideally, the cold-end metal above it
Air preheater heat balance · Gas 300 kg/s cooled from 350 °C to 135 °C; air 270 kg/s entering at 35 °C; mean cp gas 1.09, air 1.02 kJ/(kg·K); no leakage
- Heat from gas = 300 × 1.09 × (350 − 135) = 70,305 kW
- Air temperature rise = 70,305/(270 × 1.02) = 255.3 K
- Hot air leaves at 290 °C
- Cold-end metal ≈ (135 + 35)/2 = 85 °C
Answer: 70.3 MW recovered; air reaches 290 °C, but the cold-end metal is near 85 °C
Correcting a Ljungström exit temperature for leakage · Measured gas leaving a regenerative APH 132 °C; air leakage 10 % of the gas mass; air in 32 °C; cp air/gas = 1.02/1.09; THE PLANT's sensitivity 0.448 points per 10 °C
- Energy balance of the mixing: gas × 1.09 × (t_NL − 132) = 0.10 × gas × 1.02 × (132 − 32)
- t_NL = 132 + 0.10 × (1.02/1.09) × 100 = 141.4 °C
- The heat-loss method must use 141.4 °C, not 132 °C
- Efficiency overstated by (141.4 − 132) × 0.0448 = 0.42 points if the reading is used directly
Answer: True exit 141.4 °C; ignoring leakage overstates η by about 0.42 points
Feedwater treatment: hardness, demineralisation, deaeration and boiler blowdown
Which syllabus covers thisAU CME384 Unit I (feed water treatment)VTU not in syllabusSPPU 402049 Unit 2 (water treatment in thermal plants)MU not in syllabusKTU not in syllabus
What do impurities in feedwater do to a boiler?
Three things. Hardness salts (calcium and magnesium) and silica deposit as scale: a thin, insulating layer that makes tube metal run hotter until it bulges or bursts. Dissolved oxygen and carbon dioxide corrode steel, the CO2 as carbonic acid. High dissolved solids make boiler water foam, so droplets carry salts over into the superheater and turbine. That is why limits tighten with pressure. BEE's recommended feed-water limits allow hardness of 1.0 ppm up to 20 kg/cm² but 0.5 ppm at 21-39 kg/cm², and silica of 1.0, 0.3 and 0.1 ppm in the three pressure bands up to 59 kg/cm².
How is make-up water treated before it reaches the boiler?
Softening swaps calcium and magnesium for sodium in an ion-exchange bed: no scale, but the dissolved solids stay. Demineralisation (DM) uses a cation bed (hydrogen form) and an anion bed (hydroxide form) to remove almost every ion, and reverse osmosis pushes water through a membrane ahead of it. THE PLANT is a once-through supercritical unit: no drum and no blowdown, so whatever enters must leave in the steam or deposit. Feedwater carrying just 1 ppm of solids would bring about 12.4 t of them in a year at 75 % load factor. Hence DM make-up, condensate polishing and all-volatile or oxygenated treatment.
How much water must a drum boiler blow down, and what does it cost?
Steam leaves almost pure, so solids pile up in the drum until some water is drained: blowdown. A solids balance gives blowdown/steam = F/(D − F), where F is the feed TDS and D the drum limit. For the book's assumed 150 t/h industrial boiler at 4.5 MPa (IS 10392 band 500-1,500 ppm) with 20 ppm feed and a 1,000 ppm limit, blowdown is 2.04 %, 0.85 kg/s of saturated water at 257 °C carrying 847 kW above 30 °C make-up. A flash tank at 0.2 MPa turns 28 % of it into steam for the deaerator, cutting the loss to 232 kW.
Why does heating feedwater to its boiling point drive out oxygen?
Henry's law: dissolved O2 is proportional to the partial pressure of O2 above the water. Under air at 1 atm, water holds 8.37 mg/kg at 25 °C, 4.77 at 60 °C and 1.65 at 90 °C (IAPWS Henry's constants). As water nears boiling, its own vapour fills the space above it and pushes the air out, so at saturation the O2 partial pressure, and the O2, go to zero. A pressure deaerator at 0.12 MPa holds water at 104.8 °C and vents the gases; 0.02 K below saturation leaves about 4.4 ppb, against BEE's 0.005 mg/litre, while 1 K below leaves 219 ppb.
What is internal treatment, and why do high-pressure boilers avoid sodium sulphite?
Internal treatment conditions the water inside the boiler. Phosphate keeps any remaining hardness as a soft sludge that blowdown removes (BEE: 20-40 ppm residual up to 39 kg/cm², 15-25 ppm at 40-59). Oxygen scavengers mop up what the deaerator leaves. Sodium sulphite works by 2Na2SO3 + O2 → 2Na2SO4: 7.88 kg per kg O2, adding 8.88 kg of dissolved salt. Hydrazine, N2H4 + O2 → N2 + 2H2O, needs 1 kg and adds no solids, so BEE notes it is used in high-pressure boilers. Ammonia or amines then hold the pH up (all-volatile treatment).
A boiler's drum TDS limit is raised from 1,000 ppm to 2,000 ppm with the same 20 ppm feed. The blowdown rate…
Blowdown/steam = F/(D − F): 20/980 = 2.04 % becomes 20/1,980 = 1.01 %, about half. But a 2,000 ppm drum is only allowed below about 39 kg/cm² (IS 10392); at 4.5 MPa the limit is 500-1,500 ppm.
Worked examples
Blowdown rate for a 40 t/h process boiler · 40 t/h steam; 70 % condensate return (taken as solids-free), 30 % make-up with 250 ppm TDS; maximum drum TDS 3,000 ppm (BEE limit for a package boiler)
- Feed TDS = 0.30 × 250 = 75 ppm
- BEE form: blowdown/feed = 75/3,000 = 2.5 %
- Per steam: 75/(3,000 − 75) = 2.56 %
- Blowdown = 40 × 0.0256 = 1.026 t/h = 1,026 kg/h
Answer: About 2.6 % of the steam, 1,026 kg/h
Flash steam from continuous blowdown · 1.2 t/h of blowdown from a drum at 3.0 MPa into a flash vessel at 0.25 MPa; IF97: hf(3.0 MPa) = 1,008.4, hf(0.25 MPa) = 535.4, hg(0.25 MPa) = 2,716.5 kJ/kg; make-up 30 °C (125.8 kJ/kg); boiler 80 %, coal 4,000 kcal/kg
- Flash fraction x = (1,008.4 − 535.4)/(2,716.5 − 535.4) = 0.2169
- Flash steam = 1,200 × 0.2169 = 260 kg/h at 127 °C
- Heat recovered in that steam = 0.0723 kg/s × (2,716.5 − 125.8) = 187 kW
- Coal saved = 187 × 3,600/(0.80 × 4,000 × 4.1868) = 50.3 kg/h
Answer: 21.7 % flashes: 260 kg/h of steam, about 1.21 t of coal a day
Why chemicals alone are a poor deaerator · 100 t/h feed from an open hot-well at 60 °C under air (O2 from Henry's law); option A: sodium sulphite only; option B: a pressure deaerator to 0.02 K below saturation, then sulphite
- O2 at 60 °C = 4.77 mg/kg → 0.477 kg/h of O2
- A: sulphite = 0.477 × 7.88 = 3.76 kg/h, adding 42.3 ppm of sodium sulphate to the feed
- B: the deaerator leaves 4.4 ppb → 0.44 g/h of O2; sulphite 3.5 g/h
- Hydrazine would add no solids but is toxic, so it is dosed only for the last traces
Answer: Mechanical deaeration removes 99.91 % of the oxygen; chemicals only polish the rest
Steam condensers: vacuum, air leakage, cooling water flow and terminal temperature difference
Which syllabus covers thisAU CME384 Unit I (condensers)VTU not in syllabusSPPU 402049 Unit 2 (condensers, Dalton's law, vacuum efficiency, air leakage)MU not in syllabusKTU not in syllabus
Why does a steam plant need a condenser and a vacuum at all?
The turbine can only expand steam down to the pressure it exhausts into. THE PLANT exhausts at 10.3 kPa absolute, where steam condenses at 46.4 °C, ten times below the atmosphere. Exhausting to the air instead (101.3 kPa, 100 °C) would cut the LP turbine's work by 99 MW of the 660 MW. Condensing also turns the steam back into water, so pumps taking 2.4 % of the turbine work replace a compressor, and the same pure water goes round again. The price is a big heat sink: 740.3 MW leaves in the cooling water, more than the plant's output.
Surface or jet condenser, once-through or closed cooling?
A surface condenser keeps the cooling water inside tubes and the steam outside, so the condensate stays pure enough for a 24.2 MPa boiler; every large Indian unit uses one. A jet (direct-contact) condenser sprays cooling water into the steam: cheaper, but the water must be as clean as the condensate, which is why it appears only in indirect dry-cooling systems (CERC adds 0.5 % auxiliary power for them). Once-through cooling takes river or sea water and returns it warmer; MoEFCC's December 2015 notification made inland once-through plants install cooling towers and meet 3.5 m³/MWh.
How are cooling water flow, TTD and condenser pressure linked?
The cooling water carries the duty: 740.3 MW at a 10 K rise needs 17,711 kg/s (63,758 m³/h). The steam condenses at the saturation temperature of the condenser pressure, and the terminal temperature difference (TTD) is how far that sits above the water leaving: 46.39 − 42 = 4.39 K at 10.3 kPa. A cleaner tube, more tube area or more water lowers the TTD and the pressure; warmer water raises everything. Slide them in the interactive: the condenser is solved with ε-NTU, its UA set so the book's design gives 10.3 kPa.
What does air leaking into the condenser do?
Air leaks in through glands and flanges and does not condense. By Dalton's law the condenser pressure is the steam's partial pressure plus the air's. The vacuum pump has to carry the air out, and with an assumed 5 m³/s pump the air needs 0.15 kPa at the design 30 kg/h. At 300 kg/h it needs 1.53 kPa: the back pressure climbs to 11.72 kPa, the unit loses 5 MW, the condensate comes out 2.8 K below saturation and the vacuum efficiency falls to 98.3 %. Steam-jet ejectors or liquid-ring pumps remove it.
How much output does one kPa of back pressure cost?
At a fixed steam flow, every kJ the LP turbine cannot extract goes to the condenser. Near 10.3 kPa THE PLANT loses 3.7 MW per kPa (exhaust-end model; full re-runs of the plant model give 3.34). Cooling water at 36 °C instead of 32 °C: 12.66 kPa and 7.9 MW lost. Tubes fouled to 70 % UA: 6.4 MW. 80 % water flow: 3.6 MW. Real last-stage blades stop gaining below some back pressure, which this model does not know, so read its cold-water gains as optimistic.
A hot afternoon: THE PLANT's cooling water arrives at 36 °C instead of 32 °C, same flow, same steam. The condenser pressure…
The water still rises by about 10 K, so it leaves near 46 °C, and the steam must condense a few kelvin above that: 50.5 °C, which is 12.66 kPa. At 3.7 MW per kPa that is 7.9 MW gone with no saving in coal, and the heat rate rises to 8,950 kJ/kWh.
Worked examples
Cooling water flow, TTD, LMTD and UA of THE PLANT's condenser · Condenser duty 740.3 MW at 10.3 kPa; cooling water 32 → 42 °C, cp 4.18 kJ/(kg·K); ignore air
- Cooling water flow m = Q/(cp ΔT) = 740.3 × 1000/(4.18 × 10) = 17,711 kg/s = 63,758 m³/h
- Saturation temperature at 10.3 kPa (IF97) = 46.39 °C
- TTD = 46.39 − 42 = 4.39 K; inlet difference 46.39 − 32 = 14.39 K
- LMTD = (14.39 − 4.39)/ln(14.39/4.39) = 8.42 K
- UA = Q/LMTD = 740.3/8.42 = 87.9 MW/K
- Condenser efficiency = rise/(Tsat − Tin) = 10/14.39 = 69.5 %
Answer: 17,711 kg/s of cooling water, TTD 4.4 K, LMTD 8.42 K, UA about 88 MW/K
Dalton's law and vacuum efficiency from a condenser test · Original test readings: vacuum gauge 90.2 kPa, barometer 101.3 kPa, condensate 45 °C
- Absolute pressure p_c = 101.3 − 90.2 = 11.1 kPa
- Steam partial pressure = saturation pressure at 45 °C = 9.594 kPa
- Air partial pressure p_a = 11.1 − 9.594 = 1.506 kPa (Dalton)
- Ideal vacuum = 101.3 − 9.594 = 91.71 kPa; vacuum efficiency = 90.2/91.71 = 98.36 %
- Air density = p_a/(R T) = 1.506/(0.287 × 318.15) = 0.01649 kg/m³; steam = 9.594/(0.4615 × 318.15) = 0.06534 kg/m³
- So the mixture drawn off carries 0.252 kg of air per kg of steam
Answer: Vacuum efficiency 98.4 %; the air accounts for 1.51 kPa of the 11.1 kPa
What warm cooling water costs THE PLANT · Cooling water at 36 °C instead of 32 °C, same flow and tube condition, same main steam flow (525.7 kg/s); LP exhaust flow 328.6 kg/s, ηLP 0.89, generator × mechanical 0.985
- Solving the condenser (ε-NTU with the design UA, design air leakage): p_c = 12.66 kPa, Tsat 50.5 °C, water out 46.11 °C
- LP exhaust enthalpy rises from 2,423.6 to 2,448.1 kJ/kg (same expansion line, higher end pressure)
- Work lost = 328.6 × (2,448.1 − 2,423.6) × 0.985/1000 = 7.93 MW
- The fuel is unchanged, so the heat rate rises: 8,842 × 660/652.1 = 8,950 kJ/kWh
- Average slope = 7.93/(12.66 − 10.3) = 3.36 MW/kPa, below the 3.7 at 10.3 kPa: the curve flattens as the pressure rises
Answer: 12.7 kPa and about 7.9 MW lost; heat rate up 1.2 %
Cooling towers: range, approach, evaporation loss, blowdown and cycles of concentration
Which syllabus covers thisAU not in syllabusVTU BME515D Module 1 (cooling towers and ponds)SPPU 402049 Unit 2 (cooling towers)MU not in syllabusKTU not in syllabus
What are range, approach and tower effectiveness?
Range is how much the tower cools the water: 42 → 32 °C, 10 K for THE PLANT, set by the condenser's heat and the water flow. Approach is how close the cold water gets to the air's wet-bulb temperature: 32 − 27 = 5 K. No wet tower can cool below the wet bulb, so approach is the better measure of the tower itself (the BEE guide says so). Effectiveness = range/(range + approach) = 10/15 = 66.7 %. Move the sliders: a 3 K approach looks like a small change, but the tower it needs is far bigger.
How much water does the tower evaporate?
Most of the heat leaves as latent heat of the water that evaporates. The BEE guide's formula, E = 0.00085 × 1.8 × circulation (m³/h) × range, gives 976 m³/h for THE PLANT (63,758 m³/h through a 10 K range). An energy balance on the air (L/G 1.3, air leaving saturated at 36.5 °C) gives 908 m³/h, with 83 % of the heat carried as latent heat. Changing the range does not change this estimate: a bigger range means less water through the tower, and the product is the heat load.
What are cycles of concentration, blowdown and drift?
Evaporation leaves the salts behind, so the circulating water gets saltier. Cycles of concentration (COC) is circulating salts ÷ make-up salts. To hold it you purge water: E/(COC − 1), part as drift (droplets carried out, 0.02 % of circulation is the usual specification) and the rest as blowdown. At COC 5: purge 244 m³/h, drift 13, blowdown 231, make-up 1,219 m³/h = 1.85 m³/MWh. At COC 2 the make-up rises to 2.96 m³/MWh, almost the whole 3.0 m³/MWh MoEFCC norm for new plants.
What sets the size of a cooling tower?
Merkel treated the tower as heat flowing from water to air in proportion to the enthalpy gap between saturated air at the water temperature and the air around it. The tower's required size is the Merkel number KaV/L = ∫ cp dT/(hs − ha), usually found with four Chebyshev points at 0.1, 0.4, 0.6 and 0.9 of the range. For THE PLANT it is 1.33, within 0.04 % of a fine integration. Cut the approach to 3 K and it becomes 2.37; at 2 K approach and 16 K range, 4.62. The gap shrinks at the cold end, near the wet bulb.
Natural draught, induced draught or dry cooling?
A natural-draught tower is a tall hyperbolic concrete shell: the warm, moist air inside is lighter than the air outside and rises on its own, so it needs no fans. An induced-draught tower uses fans on top of shorter cells; CERC allows 0.5 % extra auxiliary power for them, 3.3 MW for THE PLANT. Where water is scarce, air-cooled condensers use no water for cooling at all (NTPC North Karanpura's first 660 MW unit, January 2023) at 1 % more auxiliary power. Hot humid days hurt all of them: a 30 °C wet bulb gives 35 °C cold water and 6 MW lost in the condenser.
THE PLANT runs its tower at 2 cycles of concentration instead of 5. The make-up water…
Evaporation is fixed by the heat load (976 m³/h). The purge is E/(COC − 1): 244 m³/h at COC 5 but 976 m³/h at COC 2. Make-up = E + purge = 1,951 m³/h, 2.96 m³/MWh: the tower alone nearly uses up the 3.0 m³/MWh norm.
Worked examples
THE PLANT's cooling tower water balance · Circulation 63,758 m³/h (17,711 kg/s, 1,000 kg/m³), range 10 K, COC 5, drift 0.02 %, 660 MW
- Evaporation (BEE) = 0.00085 × 1.8 × 63,758 × 10 = 976 m³/h
- Purge = E/(COC − 1) = 976/4 = 244 m³/h
- Drift = 0.0002 × 63,758 = 12.8 m³/h; blowdown = 244 − 12.8 = 231.1 m³/h
- Make-up = E + blowdown + drift = 1,219 m³/h
- Per MWh: 1,219/660 = 1.85 m³/MWh; salt check: make-up = COC × (blowdown + drift) = 5 × 243.9 = 1,219
Answer: Make-up 1,219 m³/h, 1.85 m³/MWh for the tower: inside the 3.0 m³/MWh plant norm, which also has to cover ash handling and the rest
Range, approach, effectiveness and losses from a tower test · Original test on a process plant tower: hot water 41.5 °C, cold 33 °C, wet bulb 28.2 °C, circulation 2,400 m³/h, COC 4
- Range = 41.5 − 33 = 8.5 K; approach = 33 − 28.2 = 4.8 K
- Effectiveness = 8.5/(8.5 + 4.8) = 63.9 %
- Heat rejected = 2,400/3.6 × 4.18 × 8.5 = 23,687 kW
- Evaporation = 0.00085 × 1.8 × 2,400 × 8.5 = 31.2 m³/h
- Purge = 31.2/3 = 10.4 m³/h, of which drift 0.48 m³/h; make-up 41.6 m³/h
Answer: Effectiveness 63.9 %, 23.69 MW rejected, make-up 41.6 m³/h
Merkel number of THE PLANT's tower by the four-point Chebyshev rule · Water 42 → 32 °C, wet bulb 27 °C (dry bulb 30 °C), L/G 1.3 (assumed), cp 4.18; inlet air enthalpy 84.93 kJ/kg
- Air line: ha = 84.93 + 1.3 × 4.18 × (T − 32); it leaves at 139.27 kJ/kg
- T = 33 °C: hs = 116.53, ha = 90.36, Δh = 26.17 kJ/kg
- T = 36 °C: hs = 135.81, ha = 106.66, Δh = 29.14 kJ/kg
- T = 38 °C: hs = 150.25, ha = 117.53, Δh = 32.72 kJ/kg
- T = 41 °C: hs = 174.69, ha = 133.83, Δh = 40.86 kJ/kg
- KaV/L = 4.18 × 10/4 × (1/26.17 + 1/29.14 + 1/32.72 + 1/40.86) = 1.333
Answer: KaV/L ≈ 1.33, within 0.04 % of a 4,000-strip integration; the smallest gap, at the cold end, weighs most
Diesel power plants: layout, engine systems, part-load fuel use and choosing the number of sets
Which syllabus covers thisAU CME384 Unit II (diesel power plant components)VTU BME515D Module 1 (diesel engine power system)SPPU 402049 Unit 3 (diesel engine power plant)MU not in syllabusKTU not in syllabus
What does a diesel power plant consist of?
Engine and alternator on one base, plus six systems. Fuel: storage tank, day tank, filters and the injection pump. Air intake: filter, turbocharger and charge-air cooler, because the engine compresses air 14:1 to 25:1 until it reaches 700-900 °C and the injected diesel ignites by itself (BEE). Exhaust: silencer and stack; a 500 kVA Cummins set exhausts at 464 °C. Cooling: jacket water through a radiator or heat exchanger. Lubrication: sump, pump, filters and cooler. Starting: a 24 V electric starter on small sets, compressed air on big engines.
Where does a diesel set's fuel energy go?
The BEE guide's typical balance: 35 % leaves as electricity, 4 % is lost in the alternator, 33 % goes up the stack, 24 % into the cooling water and 4 % is radiated. The stack is the big target: BEE estimates the recoverable heat as kWh × 8 kg of gas per kWh × 0.25 kcal/(kg·°C) × (gas temperature − 180 °C), stopping at 180 °C to stay above the acid dew point. For a set at 605 kW with 464 °C exhaust that is 400 kW, about a quarter of its fuel input.
Why does a diesel set burn more fuel per kWh at part load?
Fuel flow falls in a nearly straight line with load, but it does not reach zero: friction, pumps and the radiator fan burn fuel even with no load. Through a Cummins 400 kWe datasheet's 75 % and 100 % points the line is 8.4 L/h + 0.2381 L/kWh × load. So the specific fuel consumption is 0.259 L/kWh at full load, 0.28 at 50 % and 0.308 at 30 % (below 75 % the line is an extrapolation). BEE's monitored Indian sets ran 0.290-0.362 L/kWh. Keep running sets well loaded.
One big set or several small ones?
Take an original island town whose load swings from 700 kW at night to 2,480 kW at 7 pm (35,410 kWh a day). Four 800 kW sets with a 10 % spinning reserve run one to four sets as needed: 9,490 L of diesel, 3.73 kWh per litre, ₹25.51/kWh of fuel at ₹95.20/L, average loading 70 %. Two 1,600 kW sets: 9,742 L. One 3,200 kW set: 5.8 % more fuel than four, and no spare when it trips. BEE suggests rating sets 10-20 % above demand and running them in parallel.
Where do diesel plants make sense in India today?
As standby for hospitals, data centres and factories, for islands and remote sites off the grid, and for black start. They start in 15-20 minutes from cold (BEE), need little cooling water and are cheap to build, but their fuel is the costliest per kWh of any plant in this book. India's grid has only 288.34 MW of diesel stations, 0.05 % of 563,113 MW installed (CEA, October 2026); most diesel capacity is captive and standby. New gensets up to 800 kW must meet the CPCB IV+ emission norms (G.S.R. 804(E), November 2022), in force from 1 July 2023.
The island town's day (35,410 kWh) on one 3,200 kW set instead of four 800 kW sets. The fuel…
Each set burns 21 L/h per MW of rating just to keep turning. One 3,200 kW set pays that on 3,200 kW for all 24 hours; four smaller sets stop the ones not needed at night. Fuel: 10,044 L against 9,490 L.
Worked examples
Fuel line, part-load SFC and efficiency of a diesel set · Datasheet: 400 kWe prime, 79.83 L/h at 75 % and 103.64 L/h at 100 % load; diesel s.g. 0.85, NCV 42.8 MJ/kg (assumed); the set runs at 160 kW
- Slope b = (103.64 − 79.83)/(400 − 300) = 0.2381 L/kWh
- No-load fuel = 103.64 − 0.2381 × 400 = 8.4 L/h (a = 0.021 L/h per kW of rating)
- At 160 kW: 8.4 + 0.2381 × 160 = 46.5 L/h, SFC 0.2906 L/kWh = 247 g/kWh
- Efficiency = 3,600/(SFC × 0.85 × 42,800) = 34.1 % at 40 % load
- At full load: SFC 0.2591 L/kWh, efficiency 38.2 %
Answer: 0.291 L/kWh and 34.1 % at 40 % load, against 0.259 L/kWh and 38.2 % at full load
Dispatching the island town's diesel station · Original load: 700 kW at 3 am, 2,480 kW at 7 pm, 35,410 kWh a day; four 800 kW sets, 10 % spinning reserve; fuel 16.8 L/h + 0.2381 L/kWh × P per set; ₹95.20/L
- 3 am: 700 × 1.1 = 770 kW ≤ 800, so one set: 16.8 + 0.2381 × 700 = 183.5 L/h (87.5 % loaded)
- 7 pm: 2,480 × 1.1 = 2,728 kW needs 4 sets of 800 (3,200 kW), each at 620 kW: 4 × 16.8 + 0.2381 × 2,480 = 657.7 L/h
- Over the day (hour by hour the same way): 9,490 L for 35,410 kWh = 3.73 kWh/L
- Fuel cost = 9,490 × 95.20/35,410 = ₹25.51/kWh
- Average loading of the running sets = 35,410/Σ(running kW × 1 h) = 70.3 %
Answer: 9,490 L/day, ₹25.51/kWh of fuel alone, all four sets needed only in the evening
Heat balance and waste-heat potential of one set · An 800 kW set at 605 kW (8 pm share of 2,420 kW on four sets); exhaust 464 °C; NCV 42.8 MJ/kg (assumed); BEE: 8 kg gas per kWh, cp 0.25 kcal/(kg·°C), stop at 180 °C
- Fuel = 16.8 + 0.2381 × 605 = 160.9 L/h = 136.7 kg/h
- Heat input = 136.7 × 42,800/3,600 = 1,625 kW; electrical efficiency 605/1,625 = 37.2 %
- Waste heat potential = 605 × 8 × 0.25 × (464 − 180) = 343,640 kcal/h = 400 kW
- That is 24.6 % of the fuel input, enough for a small absorption chiller or process water
Answer: Efficiency 37.2 %; about 400 kW recoverable from the exhaust
Gas turbine power plants: open and closed cycles, optimum pressure ratio and the effect of ambient temperature
Which syllabus covers thisAU CME384 Unit II (Brayton cycle analysis and optimisation)VTU not in syllabusSPPU 402049 Unit 4 (GTPP, maximum and optimum pressure ratio)MU not in syllabusKTU PEMET631 Module 3 (gas turbine power plants)
What is in a gas turbine plant, and why does the compressor matter so much?
Air is drawn through a filter into an axial compressor, burned with gas or liquid fuel in the combustor, expanded through the turbine and sent up the stack (or into a heat recovery boiler, chapter 17). The turbine drives the compressor and the generator on one shaft. THE GAS TURBINE (pressure ratio 17, 1,300 °C, ISO air at 15 °C) makes 842.6 kJ per kg of air in its turbine, but the compressor takes 410.3 kJ, 49 % of it. Net: 432.3 kJ/kg, 39.5 % efficiency, exhaust 582 °C.
Which pressure ratio gives the most work, and which the best efficiency?
Raise the pressure ratio and the turbine work grows, but the compressor work grows faster; somewhere between, the net work peaks. For an ideal cycle the peak is at (T3/T1)^(γ/(2(γ−1))) = 19.5 for 1,300 °C and 15 °C. With THE GAS TURBINE's real compressor and turbine it falls to 15.5. Efficiency keeps rising beyond that and peaks only at 44.4. Real machines sit between the two: high enough for efficiency, low enough to keep the work per kg (and so the size for a given output) reasonable.
Why do makers keep raising the turbine inlet temperature?
The hotter the gas entering the turbine, the more work each kg of air gives, and the higher the best pressure ratio. With THE GAS TURBINE's components: at 1,100 °C the work peaks at 328 kJ/kg at pressure ratio 12; at 1,500 °C, 545 kJ/kg at 19.4. More work per kg means a smaller machine for the same megawatts. The limit is the first-stage blades, which run in gas far hotter than their metal can stand and survive only with internal air cooling and ceramic coatings.
Why does a gas turbine lose output on a hot afternoon?
The compressor swallows a fixed volume of air. Hot air is thinner, so less mass goes through, and each kg needs more compressor work. Model THE GAS TURBINE at a fixed volume flow (500 kg/s at ISO, 216 MW): at 45 °C it gives 176 MW, 18.6 % less, and the heat rate rises 3.7 %. Wärtsilä quotes 5-10 % output loss per 10 °C above 15 °C. Inlet air cooling helps: an evaporative cooler at THE SITE (30 °C dry, 27 °C wet bulb, 85 % effective, assumed) cools the air to 27.45 °C and adds 3.4 MW.
Open or closed cycle, and how much is India using its gas plants?
An open cycle takes in fresh air and throws away the exhaust. A closed cycle keeps one gas circulating: a heat exchanger heats it (so any heat source works) and a precooler cools it before the compressor. It can run at a high pressure level for a compact machine and use a better gas: helium in THE GAS TURBINE's machine peaks in work at pressure ratio 6.2, not 15.5. India has 19,144 MW of gas plants, 3.4 % of capacity (CEA, October 2026), yet gas gave less than 2 % of generation (Ministry of Power, July 2026): little affordable gas. Regeneration and intercooling are in the Thermal Engineering book.
On a 45 °C afternoon, at the same pressure ratio and turbine inlet temperature, THE GAS TURBINE's output is…
Two losses multiply. The air mass flow falls with density: 288.15/318.15 = 0.906. Each kg also needs more compressor work, so net work falls from 432.3 to 388.3 kJ/kg. Output 176 MW against 216 MW: 18.6 % lower, inside the published 5-10 % per 10 °C.
Worked examples
Optimum pressure ratio of a simple gas turbine cycle · Original machine: turbine inlet 1,150 °C, ambient 30 °C, ηc 0.86, ηt 0.89; air cp 1.005 kJ/(kg·K), γ 1.4 throughout
- Ideal: rp = (T3/T1)^(γ/(2(γ−1))) = (1,423.15/303.15)^1.75 = 14.97; its work = cp(√T3 − √T1)² = 414.7 kJ/kg
- Real (same γ): rp = (ηc ηt T3/T1)^1.75 = (0.86 × 0.89 × 4.6945)^1.75 = 9.38
- At that ratio: T2 = 618.8 K, T4 = 824.7 K
- Net work = 1.005 × [(1,423.2 − 824.7) − (618.8 − 303.1)] = 284.1 kJ/kg
- Efficiency = net work/(cp (T3 − T2)) = 35.2 %
Answer: rp ≈ 9.4 for maximum work with real components (15 ideal), 284 kJ/kg and 35.2 %
THE GAS TURBINE at ISO conditions by hand · rp 17, T1 15 °C, T3 1,300 °C, ηc 0.88, ηt 0.90; air cp 1.005, γ 1.4; gas cp 1.148, γ 1.333; LHV 50,000 kJ/kg; combustor balance from 25 °C
- T2s = 288.15 × 17^(0.4/1.4) = 647.4 K; T2 = 288.15 + (647.4 − 288.15)/0.88 = 696.4 K
- T4s = 1,573.15/17^(0.333/1.333) = 775.2 K; T4 = 1,573.15 − 0.90 × (1,573.15 − 775.2) = 855 K
- Fuel per kg air f = (1.148 × 1,275 − 1.005 × 398.2)/(50,000 − 1.148 × 1,275) = 0.02191
- Compressor 410.3 kJ/kg; turbine (1 + f) × 1.148 × (718.2) = 842.6 kJ/kg; net 432.3 kJ/kg
- η = 432.3/(0.02191 × 50,000) = 39.46 %; heat rate 3,600/η = 9,124 kJ/kWh
Answer: 39.5 %, 432.3 kJ/kg, exhaust 582 °C, heat rate 9,124 kJ/kWh
THE GAS TURBINE on a 45 °C afternoon · Same machine and pressure ratio; ISO air flow 500 kg/s (assumed) at a fixed volume flow, so mass ∝ 1/T1
- ISO output = 500 × 432.3/1000 = 216.1 MW
- Air flow at 45 °C = 500 × 288.15/318.15 = 452.9 kg/s
- At T1 = 318.15 K: T2 = 768.9 K, net work 388.3 kJ/kg, efficiency 38.05 %
- Output = 452.9 × 388.3/1000 = 175.8 MW (−18.6 %)
- Heat rate 9,461 kJ/kWh against 9,124 (+3.7 %)
Answer: 176 MW instead of 216 MW: 0.62 % per °C, inside the published 0.5-1 % per °C
Combined cycle plants: the heat recovery steam generator, pinch point and IGCC
Which syllabus covers thisAU CME384 Unit II (combined cycle, IGCC)VTU not in syllabusSPPU 402049 Unit 4 (combined cycle, IGCC)MU not in syllabusKTU PEMET631 Module 2 (combined cycle)
What is a combined cycle plant, and where does its extra power come from?
A gas turbine throws its exhaust away hot: the book's gas turbine leaves at 582 °C and turns only 39.5 % of the fuel into work. A combined cycle passes that exhaust through a heat recovery steam generator (HRSG), a boiler with no burner, and runs a steam turbine on the steam. With an assumed 600 kg/s of air, the gas turbine gives 259 MW and the steam side 100 MW more from the same fuel: combined efficiency 54.6 %, heat rate 6,592 kJ/kWh. Move the sliders and watch the T-Q diagram.
What are the pinch point and the approach in an HRSG?
Pinch: how far the gas leaving the evaporator stays above the boiling temperature. Approach: how far the economiser water stays below boiling, so it never boils in the economiser. Typical values are a pinch of 5 to 15 K and an approach near 10 K (Thermoptim, Mines Paris). The pinch fixes the steam: gas above the pinch boils and superheats the water. At 8 MPa and a 10 K pinch, 100 kg/s of exhaust raises 14.2 kg/s of steam and leaves the stack at 174 °C. A smaller pinch gives more steam but needs more tube surface.
How do you combine the gas and steam efficiencies?
Let ηG be the gas turbine efficiency and ηS the steam side's work per unit of the heat the gas turbine rejects. The gas turbine turns ηG of the fuel into work and rejects (1 − ηG). The steam side turns ηS of that into work. Total: ηG + ηS(1 − ηG). For the default plant, ηG = 39.5 % and ηS = 25 %, giving 54.6 %. ηS is low because the HRSG cannot cool the gas below about 174 °C and the steam cycle has no reheat.
Why do large plants use two or three pressure levels, and what does duct firing do?
With one pressure, the water and gas lines on the T-Q diagram only meet at one pinch, so the stack stays hot (174 °C here). Large plants add a low-pressure (and an intermediate) drum that boils water at a lower temperature and pull more heat out of the gas. Duct firing burns extra gas in the exhaust. Firing to 750 °C (assumed) raises the steam turbine from 100 to 161 MW, but efficiency falls from 54.6 to 54 %. The extra fuel only gets the steam cycle's efficiency.
What is IGCC, and why is it hard with Indian coal?
Integrated gasification combined cycle (IGCC) turns coal into fuel gas in a gasifier (coal, oxygen or air, and steam). The gas is cleaned of dust and sulphur, then burnt in a gas turbine with an HRSG and steam turbine behind it. The difficulty is Indian coal's high ash: the book's coal is 38 % ash. That ash has to be handled and melted or carried out of the gasifier, and gas cleaning costs money. India's Coal Gasification Mission targets 100 million tonnes of coal gasified by 2030, backed by ₹8,500 crore of incentives (PIB, 24 Sep 2025), mostly for chemicals rather than power. A gas turbine can also run as a cogeneration plant (Chapter 4).
You cut the HRSG pinch from 10 K to 5 K, keeping 8 MPa and 540 °C steam. What happens?
The gas can now cool 5 K closer to the boiling water, so more of its heat goes to steam and the stack runs cooler. The price is surface area: a smaller temperature difference needs more tubes for the same heat.
Worked examples
Steam raised behind the book's gas turbine · Exhaust 613 kg/s at 582 °C (600 kg/s air + fuel), cp 1.148 kJ/(kg·K); steam 6 MPa, 500 °C; pinch 10 K, approach 8 K; feed water 105 °C from a deaerator (original case). Steam tables: Tsat = 275.6 °C, h(6 MPa, 500 °C) = 3422.9, h(water at 267.6 °C) = 1172.6, h(feed) = 444.6 kJ/kg
- Gas leaving the evaporator = Tsat + pinch = 285.6 °C
- Heat above the pinch = 613 × 1.148 × (581.8 − 285.6) = 208.5 MW
- Steam = 208506 ÷ (3422.9 − 1172.6) = 92.7 kg/s
- Economiser duty = 92.7 × (1172.6 − 444.6) = 67.5 MW
- Stack = 285.6 − 67461 ÷ (613 × 1.148) = 189.7 °C
Answer: 92.7 kg/s of steam; the gas leaves the stack at 190 °C
Combined cycle efficiency, both ways · A gas turbine of 38 % efficiency; the HRSG recovers 75 % of its rejected heat; the steam cycle turns 33 % of the steam heat into work (original)
- ηS = 0.75 × 0.33 = 0.2475
- Formula: ηcc = 0.38 + 0.2475 × (1 − 0.38) = 0.5334
- Energy route per 100 MW fuel: GT 38 MW; rejected 62 MW; steam work 62 × 0.2475 = 15.35 MW
- Total (38 + 15.35) ÷ 100 = 0.5334
Answer: ηcc = 53.3 %: 40 % more output than the gas turbine alone from the same fuel
Heat rate and gas burnt by the default combined cycle · Interactive defaults: GT 259.4 MW + ST 99.6 MW (shaft), fuel 21.91 g per kg air × 600 kg/s, LHV 50,000 kJ/kg; natural gas taken as methane (assumed)
- Output = 359 MW; efficiency 54.6 %
- Heat rate = 3,600 ÷ 0.5461 = 6,592 kJ/kWh (LHV)
- Fuel = 600 × 0.02191 = 13.15 kg/s = 1,136 t/day
- CO2 = 13.15 × 44.01/16.04 × 3,600 ÷ 358962 kW = 0.362 kg/kWh
- THE PLANT's net heat rate is 9,407 kJ/kWh on the coal's GCV, or 8,925 kJ/kWh on its NCV (15,094 of 15,910 kJ/kg); like for like, the combined cycle uses about 26 % less heat per kWh, before its own auxiliaries
Answer: 6,592 kJ/kWh, 1,136 t of gas a day, about 0.36 kg CO2 per kWh
Nuclear energy: binding energy, fission and how little fuel a reactor burns
Which syllabus covers thisAU CME384 Unit III (basics of nuclear engineering)VTU BME515D Module 5 (fission and fusion, nuclear fuels)SPPU 402049 Unit 3 (fission, fusion, nuclear fuels)MU not in syllabusKTU PEMET412 Module 2 (reactor fuel cycle)
What is binding energy, and why does it decide which nuclei release energy?
A nucleus weighs less than its protons and neutrons apart. The missing mass, times c², is the binding energy: the work needed to pull it apart. Per nucleon it rises from 1.11 MeV in deuterium to a peak of 8.79 MeV near iron-56 and nickel-62, then falls to 7.59 MeV in uranium-235 (AME2020). Moving towards the peak releases energy: splitting heavy nuclei (fission) or fusing light ones. The semi-empirical mass formula reproduces the curve within about 1 % above A = 40 (iron: 0.6 %) but misses helium-4 by 19 %.
How much energy does one fission release, and where does it go?
A U-235 nucleus that absorbs a slow neutron splits into two fragments and 2 or 3 neutrons. For krypton-92 + barium-141 + 3 neutrons, the AME2020 masses lose 0.186 u: 173.3 MeV. The DOE handbook's average is 187 MeV at once (167 MeV as fragment motion) plus 23 MeV later from fragment decay. The 10 MeV carried by neutrinos escapes, leaving about 200 MeV of heat per fission. The extra neutrons can split more nuclei: a chain reaction. Slide the fragment mass to see the climb up the curve.
What is the difference between fissile and fertile material?
Fissile nuclei split with slow (thermal) neutrons: U-235, Pu-239 and U-233. Fertile nuclei do not, but turn into fissile ones after absorbing a neutron: U-238 becomes Pu-239, and thorium-232 becomes U-233. Natural uranium is only 0.72 % U-235 by atoms (NIST); the rest is fertile U-238. India's three-stage programme uses this: natural-uranium PHWRs make plutonium, fast breeders use it (the 500 MWe PFBR at Kalpakkam reached first criticality on 6 April 2026), and the third stage runs on U-233 bred from India's thorium.
What is burn-up, and how much of the fuel actually fissions?
Burn-up is the heat taken from a tonne of heavy metal before it is discharged, in MWd/t. One gram fissioned gives 0.95 MWd at 200 MeV per fission. Indian PHWRs discharge natural uranium at about 7,000 MWd/t (NPCIL), so only 0.74 % of the metal has fissioned. That is more than the 0.711 % of U-235 it started with: the balance is plutonium bred inside the fuel and burnt in place. Light-water fuel enriched to about 4.5 % reaches around 45,000 MWd/t (IAEA): 4.7 % fissioned.
How does a reactor's fuel compare with a coal unit's?
Kakrapar-3, a 700 MWe PHWR, makes 2,166 MW of heat (32.3 % gross efficiency). That is 6.76 × 10¹⁹ fissions a second, 2.28 kg of nuclei a day. At an assumed 80 % capacity factor it loads about 90 t of natural uranium a year. The book's coal plant would need 2.73 Mt of coal for the same gross output: 30,175 times the mass. Fuel is cheap to move; the cost of nuclear power is in building and safely running the plant.
Kakrapar-3 (2,166 MW of heat) runs a full day. How much matter is fissioned?
200 MeV per fission means 6.76 × 10¹⁹ fissions every second, which add up to 2.28 kg of uranium (and bred plutonium) nuclei a day. The book's coal unit at the same 700 MW burns 9,337 t a day.
Worked examples
Energy of one fission from atomic masses · U-235 + n → Kr-92 + Ba-141 + 3n. AME2020 atomic masses (u): U-235 235.043928, n 1.008665, Kr-92 91.926173, Ba-141 140.914404; 1 u = 931.494 MeV
- Before: 235.043928 + 1.008665 = 236.052593 u
- After: 91.926173 + 140.914404 + 3 × 1.008665 = 235.866571 u
- Mass lost = 0.186022 u
- Q = 0.186022 × 931.494 = 173.3 MeV
- Check from binding energies: 141 × 8.3261 + 92 × 8.5127 − 235 × 7.5909 = 173.3 MeV
- Rough rule: 235 nucleons gain about 0.9 MeV each = 212 MeV
Answer: 173.3 MeV promptly; the fragments' later decays bring the total to about 200 MeV of heat
Binding energy of iron-56 by the mass formula · A = 56, Z = 26; aV 15.75, aS 17.8, aC 0.711, aA 23.7, aP 11.18 MeV (Rohlf); even-even, so pairing is +aP/√A
- Volume: 15.75 × 56 = 882 MeV
- Surface: −17.8 × 56^(2/3) = −260.5 MeV
- Coulomb: −0.711 × 26 × 25 ÷ 56^(1/3) = −120.8 MeV
- Asymmetry: −23.7 × (56 − 52)² ÷ 56 = −6.77 MeV
- Pairing: +11.18 ÷ √56 = 1.49 MeV
- B = 495.4 MeV, B/A = 8.846 MeV; measured 8.790 MeV
Answer: 8.85 MeV per nucleon, 0.6 % above the measured value; surface and Coulomb terms cost 381 MeV
A 700 MWe PHWR's fuel against coal · 2,166 MW thermal, 700 MW gross; 200 MeV per fission (1 MeV = 1.602 × 10⁻¹³ J); burn-up 7,000 MWd/t of natural uranium; 80 % capacity factor (assumed); coal for the book's plant 0.556 kg per gross kWh
- Fissions per second = 2,166 × 10⁶ ÷ (200 × 1.602 × 10⁻¹³) = 6.76 × 10¹⁹
- Per day: × 86,400 ÷ 6.022 × 10²³ × 235 g = 2.28 kg
- Heat per year = 2,166 × 365 × 0.8 = 632,472 MWd
- Natural uranium = 632,472 ÷ 7,000 = 90.4 t/yr
- Coal = 700,000 kW × 8,760 h × 0.8 × 0.556 = 2.73 Mt/yr
Answer: About 90 t of uranium against 2.7 Mt of coal a year: 30,175 to 1 by mass
Neutron multiplication: the four-factor formula, moderators and criticality
Which syllabus covers thisAU CME384 Unit III (basics of nuclear engineering)VTU BME515D Module 5 (chain reaction, moderation, multiplication factor)SPPU 402049 Unit 3 (moderators, coolants)MU not in syllabusKTU PEMET412 Module 3 (moderator, core)
What is the multiplication factor k, and what does critical mean?
Count the neutrons in one generation and in the next: their ratio is k. If k = 1 the chain holds steady (critical), above 1 it grows (supercritical), below 1 it dies (subcritical). The DOE handbook follows 1,000 fast neutrons round one life cycle: fast fission adds a few, some leak out, some are caught in U-238 resonances, more leak, some are absorbed outside the fuel, and each fuel absorption makes new neutrons. Its numbers end with 1006 neutrons: k = 1.0065. The interactive runs that cycle.
What are the four (and six) factors?
ε, fast fission factor: extra neutrons from fast fission of U-238 (DOE example 1.031). p, resonance escape probability: the share that slows down without capture in U-238 resonances between about 6 and 200 eV (0.803). f, thermal utilisation: the share of thermal absorptions that happen in the fuel (0.751). η, reproduction factor: neutrons born per fuel absorption (2.012). Their product is k∞ = 1.251 for an infinite core. Two non-leakage factors, fast 0.889 and thermal 0.905, give k_eff.
Why does a reactor have a critical size?
Neutrons are made throughout the volume but escape through the surface. A small core has too much surface for its volume, so too many leak and k_eff falls below 1. In the interactive's model, leakage scales as 1/size² and the handbook's core goes critical at 0.985 of its size. A reflector (water, heavy water or graphite around the core) sends escaping neutrons back and shrinks the critical size. The book's PHWR uses its heavy-water moderator outside the fuel lattice as a reflector.
What makes a good moderator, and why can heavy water use natural uranium?
A moderator slows fission neutrons from about 2 MeV to 0.025 eV by collisions. Light nuclei take more energy per hit: ξ = 1 for hydrogen (18 collisions), 0.725 for deuterium (25), 0.158 for carbon (115). A moderator must also not absorb neutrons. The DOE handbook's moderating ratio (slowing down power ÷ absorption) is 62 for light water, 216 for graphite and 4,830 for heavy water. Light water swallows too many neutrons for natural uranium (0.72 % U-235); heavy water does not, so PHWRs need no enrichment.
What do control rods, coolants and reflectors do?
Control rods hold strong neutron absorbers (cadmium, boron, hafnium) and push k below 1 when inserted. Coolants carry the heat away: light water in PWRs and BWRs, pressurised heavy water in PHWRs, carbon dioxide in gas-cooled reactors, liquid sodium in fast breeders such as PFBR. A good coolant has high heat capacity and low neutron absorption. Reflectors surround the core and return leaking neutrons. Moderator, coolant and fuel together fix k; Chapter 20 covers how operators change it.
Why can a PHWR run on natural uranium when a light-water reactor cannot?
Deuterium is actually a slower moderator than hydrogen (25 against 18 collisions). It wins on absorption: heavy water's moderating ratio is 4,830 against 62 for light water (DOE). That saves enough neutrons to keep a chain going with only 0.72 % U-235.
Worked examples
k for a natural-uranium heavy-water lattice · ε = 1.03, fast non-leakage 0.97, p = 0.87, thermal non-leakage 0.98, f = 0.90, η = 1.34 (assumed, natural-uranium lattice)
- k∞ = 1.03 × 0.87 × 0.90 × 1.34 = 1.0807
- k_eff = 1.0807 × 0.97 × 0.98 = 1.0273
- Per 1,000 fast neutrons: 1,000, 1,030, 999, 869, 852, 767, 1,027
- Reactivity ρ = (k − 1)/k = 0.0266 = 2,658 pcm
Answer: k_eff = 1.027: supercritical by 2,658 pcm, which control devices must hold down
Collisions to thermalise in graphite and deuterium · Neutron slowed from 2 MeV to 0.025 eV; ξ = 1 + α ln α/(1 − α), α = ((A − 1)/(A + 1))²
- ln(2 × 10⁶ ÷ 0.025) = 18.198
- Carbon (A = 12): α = (11/13)² = 0.716, ξ = 0.1578
- Collisions = 18.198 ÷ 0.1578 = 115.3 (DOE table: 114)
- Deuterium (A = 2): α = 1/9, ξ = 0.7253, collisions = 25.1
- In heavy water the oxygen dilutes ξ to 0.510 (DOE): 35.7 collisions
Answer: About 115 collisions in graphite and 25 in deuterium (36 in heavy water)
Critical radius of a bare spherical core · One-group model: k_eff = k∞ ÷ (1 + M²B²), sphere B = π/R; k∞ = 1.08, migration area M² = 240 cm² (assumed)
- Critical when 1 + M²B² = k∞
- B² = (1.08 − 1) ÷ 240 = 3.333 × 10⁻⁴ cm⁻²
- R = π ÷ √B² = 172 cm
- Core volume = 21.3 m³
- Half that radius: k_eff = 1.08 ÷ (1 + 240 × (π/86)²) = 0.818
Answer: R ≈ 1.72 m; halve it and k_eff drops to 0.82
Reactor control: reactivity, delayed neutrons, the reactor period and decay heat
Which syllabus covers thisAU CME384 Unit III (safety measures)VTU BME515D Module 5 (reactor components)SPPU 402049 Unit 3 (control rods)MU not in syllabusKTU PEMET412 Module 3 (control, safety)
What is reactivity, and what are pcm and dollars?
Reactivity ρ = (k − 1)/k says how far a core is from critical. It is small, so it is quoted in pcm (per cent mille, 10⁻⁵): k = 1.003 is ρ = 299 pcm. It is also quoted in dollars, ρ ÷ β, where β is the delayed neutron fraction (0.0065 for U-235, DOE): 299 pcm is 0.46 dollars. One dollar, ρ = β, is the line operators must never cross: prompt critical, reached at k = 1.00654.
Why do delayed neutrons make a reactor controllable?
Over 99 % of fission neutrons appear at once, but 0.65 % come seconds later from decaying fission fragments (DOE lists six groups, half-lives 0.23 to 55.6 s). A generation of prompt neutrons lasts about 10⁻³ s in a heavy-water reactor (IAEA). If only they counted, a 0.1 % excess would multiply power e-fold in about a second. Delayed neutrons stretch the average generation, so +100 pcm gives a period of about 70 s: slow enough for rods and operators to follow.
What are the prompt jump and the reactor period?
After a positive reactivity step, power first jumps within a fraction of a second by about β/(β − ρ), ×1.182 for +100 pcm. Then it grows as e^(t/τ) with the stable period τ ≈ (β − ρ)/(λρ), λ = 0.08 /s (DOE): 68.7 s by the formula, 69.9 s from the exact one-group solution. At +750 pcm (above one dollar) the period collapses to 0.73 s with heavy water's generation time, and 20 ms for a light-water core's (assumed 2 × 10⁻⁵ s).
How is a reactor controlled and shut down?
Regulating rods trim power; shut-off rods drop in to trip the reactor; liquid poison injection is the second, independent way. India's PHWRs have two fast, independent shutdown systems: SDS1, cadmium shut-off rods that fall by gravity, and SDS2, gadolinium nitrate solution injected into the moderator. Either can handle the worst accident alone (IAEA TRS-407). After shutdown, power falls with a period of about −80 s, set by the 80 s mean life of the slowest delayed group. Xenon-135 (2.6 million barns) peaks about 10 hours after shutdown and can stop a restart (DOE).
Why must a shut-down reactor still be cooled?
Fission stops at a trip, but the fragments keep decaying. The Way-Wigner formula gives, after a year at full power, 4 % of full power at 10 s, 1.07 % at 1 hour and 0.47 % at 1 day. For Kakrapar-3's 2,166 MW that is 23.3 MW an hour later, enough to boil 10.3 kg of water a second. At Fukushima Daiichi in 2011 a 15 m tsunami knocked out 12 of 13 backup generators; cooling was lost and three cores largely melted within three days (WNA).
A reactor trips from full power after a year of running. What is its heat output one hour later?
Decay of fission fragments still gives 1.07 % (Way-Wigner; DOE says under about 1 %, WNA about 1.5 %). For a 2,166 MW core that is 23 MW, which must be removed for days.
Worked examples
Period and power after a small reactivity step · ρ = +100 pcm; β = 0.0065, λ = 0.08 /s (DOE); prompt generation time 10⁻³ s; reactor at P0
- Prompt jump ≈ β/(β − ρ) = 0.0065 ÷ 0.0055 = 1.182
- Period ≈ (β − ρ)/(λρ) = 0.0055 ÷ (0.08 × 0.001) = 68.75 s
- Exact one-group roots of Λs² + (Λλ + β − ρ)s − λρ = 0: s1 = 0.0143 /s, s2 = −5.594 /s → τ = 69.93 s
- Power at 60 s ≈ 1.182 × e^(60/68.75) = 2.829 P0 (exact 2.773 P0)
- Doubling time = τ ln 2 = 48.5 s
Answer: τ ≈ 70 s; power reaches 2.77 P0 after a minute and doubles every 48 s
From k to reactivity, pcm and dollars · k_eff = 1.003; β = 0.0065
- ρ = (1.003 − 1) ÷ 1.003 = 0.002991
- = 299.1 pcm
- In dollars: 0.002991 ÷ 0.0065 = 0.46
- Prompt critical when ρ = β: k = 1/(1 − 0.0065) = 1.00654
Answer: 299 pcm, 0.46 dollars: well below prompt critical (k = 1.0065)
Decay heat of Kakrapar-3 after a trip · 2,166 MW thermal, one year at full power; Way-Wigner P/P0 = 0.066[t^−0.2 − (t + T)^−0.2], T = 3.15 × 10⁷ s; latent heat of water at 1 atm 2,257 kJ/kg
- 10 s: 0.066 × (10^−0.2 − (10 + T)^−0.2) = 3.96 % = 86 MW
- 1 hour: 1.07 % = 23.3 MW
- 1 day: 0.47 % = 10.2 MW
- 30 days: 0.139 % = 3 MW
- Water boiled at 1 hour = 23270 ÷ 2,257 = 10.3 kg/s (37 t/h)
Answer: 23 MW an hour after the trip and still 3 MW a month later
Reactor types: PWR, BWR, PHWR (CANDU), gas-cooled and fast breeder reactors
Which syllabus covers thisAU CME384 Unit III (BWR, PWR, CANDU, breeder, gas and liquid metal cooled)VTU BME515D Module 5 (PWR, BWR, fast breeder, gas cooled)SPPU 402049 Unit 3 (reactor types, India's programme)MU not in syllabusKTU PEMET631 Module 3 (nuclear plant classification)
What are the main parts of a nuclear power plant?
A nuclear plant is a steam plant whose boiler is a reactor. The core holds the fuel; a moderator slows the neutrons; control rods set the power; a coolant carries the heat out. In most types the coolant gives its heat to water in a steam generator, and that steam drives an ordinary turbine, condenser and feed pumps. Everything radioactive sits inside a containment building. India's 700 MWe PHWR makes 2,166 MW of heat, turns it into 1,065 kg/s of steam at 4.31 MPa, and sends 700 MW gross to the generator: 32.3 %.
How does a pressurised water reactor work, and what is a VVER?
In a PWR ordinary water is both coolant and moderator, kept at about 15.5 MPa so it cannot boil at 325 °C. A pressuriser (a tall vessel with heaters and a steam bubble) holds that pressure. The hot water passes through thousands of U-tubes in the steam generators and makes saturated steam at 5.8-6.3 MPa for the turbine. The VVER is the Russian PWR: Kudankulam 1 and 2 are VVER-1000s of 932 MWe net each, with horizontal steam generators. Fuel is uranium oxide enriched to about 4-5 % U-235.
What makes a boiling water reactor different?
A BWR lets the water boil in the core at about 7 MPa and 288 °C, separates the steam above the core and sends it straight to the turbine: one circuit, no steam generator, no pressuriser. That is simpler and cheaper, but the turbine hall becomes part of the radioactive circuit, so it needs shielding during operation. The ABWR makes 1,420 MWe gross from 3,926 MWt (36.2 %). India's first reactors, Tarapur 1 and 2 (1969), are small GE boiling water reactors of 150 MWe net each.
Why does India build pressurised heavy water reactors?
Heavy water absorbs so few neutrons that a reactor can run on natural uranium (0.7 % U-235), and India has no enrichment for power fuel at scale. The PHWR (the Canadian CANDU design, developed further by NPCIL) puts the fuel in 392 horizontal pressure tubes through a tank of cool heavy-water moderator, the calandria; hot heavy water at 9.81 MPa and 310 °C carries the heat to the steam generators. Fuel is changed on power, reaching about 7,000 MWd/t. This is stage 1 of India's three-stage plan: PHWRs, then fast breeders on their plutonium, then thorium.
Why is a nuclear plant's efficiency so much lower than a coal plant's?
Water coolant limits the steam. The PHWR's coolant leaves the steam generator at 266 °C, so its steam can only boil at about 255 °C (4.31 MPa), against 565 °C for the book's coal plant. Efficiency follows the mean temperature at which heat is added: the ideal PHWR cycle adds heat at 210 °C on average and could reach 34 %; the real unit gets 32.3 % gross, while the coal plant's turbine cycle reaches 47.5 %. So a PHWR throws away 2.09 MW of heat per MW of electricity, the coal plant 1.12.
What do gas-cooled and liquid-metal reactors gain?
Gas and liquid metal run hotter. The British AGR blows CO2 at about 40 bar through a graphite core to about 650 °C and raises coal-plant steam (170 bar, 543 °C): about 41 % efficiency. A fast breeder has no moderator; liquid sodium at only 0.11 MPa carries the heat, entering at 397 °C and leaving at 547 °C. India's 500 MWe PFBR at Kalpakkam makes 16.7 MPa, 490 °C steam from 1,253 MWt (39.9 %), burns plutonium-uranium oxide (MOX) and breeds more fuel. It reached first criticality on 6 April 2026.
A PWR's primary water enters the steam generator at 325 °C and leaves at 279 °C. Could you raise the steam pressure from 5.8 MPa to 7 MPa for more efficiency?
Boiling water stays at its saturation temperature. The primary water must stay hotter than it all the way through, and its coldest point is the 279.4 °C leaving the generator. With a 3 K pinch the steam can boil at most at 276.4 °C, which is 6.08 MPa. At 7 MPa the steam would need to boil at 285.8 °C: impossible.
Worked examples
Heat balance of India's 700 MWe PHWR · IAEA ARIS: 2,166 MWt; 700 MWe gross; net efficiency 29 %; steam 4.31 MPa dry saturated (h = 2,799.2 kJ/kg); feedwater 180 °C at 4.31 MPa (h = 764.9 kJ/kg, IF97)
- Heat to each kg of steam = 2,799.2 − 764.9 = 2034.3 kJ/kg
- Steam flow = 2,166,000 kW / 2034.3 = 1,065 kg/s (ARIS prints 1,067 kg/s)
- Gross efficiency = 700/2,166 = 32.3 %
- Net output = 0.29 × 2,166 = 628 MWe, so the station uses 72 MW itself (10.3 % of gross)
- Steam rate = 1,065 × 3,600 / 700,000 = 5.48 kg/kWh, against 2.87 kg/kWh for the book's 660 MW coal unit
Answer: 1,065 kg/s of steam; 32.3 % gross and 29 % net (628 MWe)
How high can a PWR's steam pressure go? · AP1000 (IAEA ARIS): primary water 324.7 °C in, 279.4 °C out of the steam generator; steam 5.76 MPa; minimum pinch 3 K
- Saturation temperature at 5.76 MPa (IF97) = 272.9 °C, so today's pinch is 279.4 − 272.9 = 6.5 K
- Hottest possible boiling temperature = 279.4 − 3 = 276.4 °C
- Its saturation pressure (IF97) = 6.08 MPa
- Raising the coolant would need a higher primary pressure: water at 15.5 MPa boils at 345 °C, so 325 °C already leaves only 20 K margin
Answer: About 6.08 MPa: the steam is boxed in by the coolant, which is boxed in by the primary pressure
Cooling water for a PHWR and for the book's coal unit · PHWR gross efficiency from example 1; the book's coal unit rejects 740.3 MW in its condenser for 660 MW gross; cooling water range 10 K (book site)
- PHWR heat rejected per MW gross = (1 − 0.3232)/0.3232 = 2.09 MW (the condenser takes almost all of it)
- Coal unit: 740.3/660 = 1.12 MW per MW (the rest of its losses leave up the chimney)
- Cooling water per MW gross at a 10 K range: PHWR 50.1 kg/s, coal 26.8 kg/s
- Ratio = 1.87
Answer: A PHWR needs about 1.9 times the cooling water per MW: one reason nuclear plants sit on coasts (Tarapur, Kudankulam, Kalpakkam)
Nuclear safety, radiation shielding and waste disposal
Which syllabus covers thisAU CME384 Unit III (safety), Unit V (nuclear waste disposal)VTU BME515D Module 5 (radiation hazards, shielding, waste)SPPU 402049 Unit 3 (shielding, waste disposal)MU not in syllabusKTU PEMET412 Module 4 (radiation safety, waste)
Which radiation needs which shield?
Alpha particles stop in a sheet of paper or the outer skin; they matter only when swallowed or breathed in. Beta particles stop in a few millimetres of aluminium or plastic. Gamma rays have no fixed range: each centimetre removes the same fraction, so you count half-value layers. For Co-60 gamma rays (1.17 and 1.33 MeV) NIST's coefficients give a half-value layer of 1.04 cm of lead, 1.65 cm of steel, 5.19 cm of concrete and 11 cm of water. Neutrons are slowed by hydrogen (water, concrete) and then absorbed, often by boron.
How do time, distance and shielding cut the dose?
Dose = dose rate × time, so halve the time and you halve the dose. A small source spreads its rays over a sphere, so the rate falls with the square of distance: step from 2 m to 4 m and it drops four times. A shield multiplies it by e^(−μx). A 370 GBq Co-60 source gives 28.3 mSv/h at 2 m in the open; behind 50 cm of concrete that falls to 35.7 µSv/h. Wide beams scatter photons back into the path (buildup), so real shields are thicker than the narrow-beam figure: here up to 7.7 times the rate.
What are the dose limits?
The IAEA basic safety standards (GSR Part 3) limit a radiation worker to 20 mSv a year averaged over five years, and 50 mSv in any one year; a member of the public to 1 mSv a year from all licensed practices. A shield designer turns the limit into a rate: 20 mSv over 2,000 working hours is 10 µSv/h. For the source above that needs 60 cm of concrete or 11.9 cm of lead. Behind 50 cm of concrete a worker reaches 20 mSv in 561 hours.
What keeps a reactor safe?
Defence in depth: several independent barriers and systems, so one failure is never enough. The barriers are the ceramic fuel pellet, the sealed fuel cladding, the primary circuit and the containment building. India's 700 MWe PHWR has two fast-acting, independent shutdown systems, an emergency core cooling system that injects water into all headers after a pipe break, a passive decay heat removal system, and a double containment, the inner one designed for 0.157 MPa. Decay heat keeps coming after shutdown, so cooling must never stop for long.
What happens to nuclear waste, and to the radioactivity in coal ash?
Low-level waste (gloves, filters, resins) is compacted and buried in near-surface trenches at each site. Spent fuel first cools for years in water pools. India follows a closed fuel cycle: spent fuel is reprocessed to recover plutonium for fast breeders, and the high-level liquid left over is vitrified in borosilicate glass, at plants in Tarapur, Trombay and Kalpakkam (2013), with a deep geological repository under study. Coal has radioactivity too: USGS finds 1-4 ppm uranium in most coal, concentrated in the ash; for the book's 38 % ash coal, ash holds about 2.6 times the coal's level.
A gamma source sits behind 3 half-value layers of concrete. You add 3 more half-value layers. The dose rate…
Each half-value layer halves the rate, whatever came before: 3 more layers multiply by 0.5 × 0.5 × 0.5 = 1/8. Gamma rays have no range at which they all stop; the rate only shrinks by a fixed factor per centimetre (e^(−μx)).
Worked examples
Half- and tenth-value layers of concrete and lead for Co-60 · NIST at 1.25 MeV: concrete μ/ρ = 0.05807 cm²/g, ρ = 2.30 g/cm³; lead 0.05876 cm²/g, 11.35 g/cm³
- Concrete μ = 0.05807 × 2.30 = 0.1336 per cm; lead μ = 0.05876 × 11.35 = 0.6669 per cm
- HVL = 0.6931/μ: concrete 5.19 cm, lead 1.04 cm
- TVL = 2.3026/μ: concrete 17.24 cm, lead 3.45 cm
- A factor of 1,000 needs 3 TVL: 51.7 cm of concrete or 10.4 cm of lead
- Mass per m² is what matters: 1190 kg/m² of concrete against 1176 kg/m² of lead
Answer: HVL 5.19 cm (concrete), 1.04 cm (lead); 1/1000 needs 52 cm of concrete
Concrete wall for a Co-60 source next to a work area · 370 GBq Co-60 (assumed); worker 2 m away; design rate 10 µSv/h (20 mSv over 2,000 h); Co-60 lines 1.1732 MeV (99.85 %) and 1.3325 MeV (99.98 %); air μen/ρ = 0.02666 cm²/g; 1 Gy ≈ 1 Sv
- Energy per decay = 1.1732 × 0.9985 + 1.3325 × 0.99983 = 2.5037 MeV
- At 1 m from 1 GBq: 10⁹/(4π × 100²) × 2.5037 MeV × 1.602e-13 J/MeV × 0.02666 cm²/g × 1,000 g/kg = 8.51 × 10⁻⁸ Gy/s → 0.306 mGy/h
- Unshielded at 2 m: 370 × 0.3064 / 2² = 28.34 mSv/h
- Thickness: x = ln(28,339/10)/0.1336 = 59.5 cm
- Narrow-beam figure: add margin for buildup (scattered photons) in the real design
Answer: About 60 cm of ordinary concrete (narrow beam)
Time and distance behind an existing wall · Same source behind 50 cm of concrete; worker at 2 m; limit 20 mSv/yr
- Rate = 28,339 × e^(−0.1336 × 50) = 35.66 µSv/h
- Hours to 20 mSv = 20,000/35.66 = 561 h
- Move to 4 m: rate/4 = 8.91 µSv/h, hours = 2,244 h
- An 8-hour shift at 2 m gives 285 µSv
Answer: 561 h a year at 2 m, 2,244 h at 4 m
Hydroelectric power plants: classification, layout, the mass curve and surge tanks
Which syllabus covers thisAU CME384 Unit IV (hydro electric power plants)VTU BME515D Module 4 (storage and pondage, surge tanks)SPPU 402049 Unit 3 (hydrology, mass curve, surge tank)MU not in syllabusKTU PEMET631 Module 3 (hydro plants), Module 4 (pumped hydro)
What does a hydro engineer need to know about the river?
How much water arrives, and when. Rain falls on the catchment; part runs off into the river. A hydrograph plots river flow against time; a flow duration curve sorts the flows to show for what share of the year each flow is equalled or exceeded (the Renewable Energy book's small hydro chapter builds one). Indian rivers are monsoon rivers: the book's example river carries 175 m³/s in August and 8 m³/s in April, 22 times less, with a yearly mean of 51.4 m³/s. Without storage, the dry-season flow sets the firm power.
How are hydro plants classified?
By head: low-head plants (a few tens of metres, Kaplan turbines), medium-head (Francis) and high-head plants (hundreds of metres, Pelton wheels). By storage: run-of-river plants use the flow as it comes, storage plants hold monsoon water in a reservoir for the dry months, and pumped-storage plants pump water uphill with cheap power and generate at the peak. By load: base-load or peak-load. India had 52,315 MW of large hydro including pumped storage on 31 October 2026 (CEA), plus 5,189 MW of small hydro.
How does the mass curve size a reservoir?
Plot cumulative inflow against time: the mass curve. A uniform draft D is a straight line of slope D. Draw that line from the peak of the curve before the dry season; the largest vertical gap below it is the storage needed (Rippl's method). The sequent-peak algorithm does the same in a table: K = max(0, K + draft − inflow) month by month, storage = largest K. For the book's river and a 35 m³/s draft, both give 390 million m³, filled by the monsoon and drawn down from November to May; 31.9 % of the year's inflow still spills.
What are the parts of a hydro plant's layout?
A dam raises the water and forms the reservoir; a spillway passes floods safely. The intake, with trash racks and gates, feeds a head-race tunnel or canal, then a surge tank, then steel penstocks dropping to the powerhouse, where the turbines and generators sit; the water leaves through the draft tube and tailrace. Firm power is P = ρ g Q H η: 35 m³/s through 148.8 m of net head at 88 % gives 44.9 MW, or 394 GWh a year at full time. The Turbomachinery book covers the turbines, penstock and draft tube.
Why does a long tunnel need a surge tank, and how big must it be?
When the turbines shut suddenly, the water in a 3 km tunnel cannot stop at once; without a free surface the pressure rise (water hammer) would burst it. A surge tank near the powerhouse lets the water rise and fall instead. Its level oscillates: for the book's tunnel the first upsurge would be 13.3 m without friction, with a period of 257 s. Too small a tank lets the oscillation grow under governor action; IS 7396 sets the minimum by Thoma's criterion, 54 m² here, and asks for twice that: a 11.7 m diameter shaft.
You double the tunnel's head loss (a rougher lining) and keep everything else the same. Thoma's stable surge tank area…
Thoma area = L At v²/(2 g h_r H0): friction damps the oscillation, so more head loss means a smaller tank is stable. Here 54 m² would fall to about 27 m². The catch is that the extra loss costs head, and power, every hour the plant runs.
Worked examples
Storage by the sequent-peak method · Two-month inflows (Mm³, original): 120, 80, 30, 10, 15, 90, repeating; uniform draft 50 Mm³ per two months
- Mean inflow = 345/6 = 57.5 Mm³ per two months, above the draft, so a finite reservoir works
- K = max(0, K + 50 − Q): 0, 0, 20, 60, 95, 55
- Second year: 0, 0, 20, 60, 95, 55 (the pattern repeats)
- Largest K = 95 Mm³: the deficits of seasons 3-5 (20 + 40 + 35)
Answer: A live storage of 95 Mm³
Firm power from the book's river with storage · Uniform draft 35 m³/s (storage from the mass curve); gross head 150 m; tunnel 3 km, 5 m diameter, Manning N = 0.013; overall efficiency 0.88
- Tunnel velocity = 35/(π × 5²/4) = 1.783 m/s; hydraulic radius = 5/4 = 1.25 m
- Head loss = v² N² L/R^(4/3) = 1.783² × 0.013² × 3,000/1.25^(4/3) = 1.2 m
- Net head = 150 − 1.2 = 148.8 m
- P = 1,000 × 9.81 × 35 × 148.8 × 0.88 = 44.9 MW
- Storage needed (mass curve) = 390 Mm³; spill = 1 − 35/51.39 = 31.9 %
Answer: 44.9 MW firm, 394 GWh a year at 100 % time
Surge tank area by Thoma's criterion (IS 7396) · Same tunnel and flow; net head from example 2; simple surge tank, factor of safety 2.0
- Thoma area = L At v²/(2 g h_r H0) = 3,000 × 19.63 × 1.783²/(2 × 9.81 × 1.196 × 148.8) = 53.6 m²
- Design area = 2.0 × 53.6 = 107.2 m², diameter √(4 × 107.2/π) = 11.68 m
- Frictionless upsurge after full rejection = v √(L At/(g As)) = 13.3 m
- Period = 2π √(L As/(g At)) = 257 s
Answer: Thoma area 54 m²; build about 11.7 m diameter, with room for a 13 m upsurge
Power from renewable energy: wind, solar, tidal, geothermal, biogas and fuel cell plants
Which syllabus covers thisAU CME384 Unit IV (wind, tidal, SPV, solar thermal, geothermal, biogas, fuel cell)VTU BME654B Modules 2-5 (renewable energy power plants)SPPU 402049 Unit 6 (wind solar hybrid plants, geothermal, tidal)MU MEDLO7032 (renewable energy sources)KTU not in syllabus
Why put wind and solar behind one grid connection?
Because they rarely peak together. Solar peaks at noon and in the dry months; wind in India blows hardest in the monsoon and often in the evening. In the Renewable Energy book's Jodhpur models, 300 MWp of PV runs at a 20 % capacity utilisation factor (CUF) and 200 MW of wind at 36.1 %. Put both behind a 250 MW connection and only 0.5 % of their energy is clipped, while the line's CUF rises to 52.6 %, against 26.4 % on a full 500 MW line. MNRE counts a plant as a hybrid when the smaller source is at least 25 % of the larger.
How do solar PV and solar thermal power plants differ?
A PV plant turns light straight into DC in silicon cells, and inverters feed the grid; it has no moving parts and works with diffuse light, so cloudy months only cut its output. A solar thermal plant mirrors sunlight onto a receiver (parabolic troughs, a central tower) to heat oil or molten salt, which raises steam for a turbine; it needs strong direct sunlight but can store heat in tanks for the evening. India had 174,547 MW of solar on 31 October 2026 (CEA). The Renewable Energy book covers both in depth.
How much energy does a tidal barrage capture?
A barrage closes a bay; the basin fills on the rising tide and is let out through low-head turbines as the sea falls. The water in a basin of area A and tidal range R drops through an average height R/2, so one emptying releases ρ g A R²/2. A basin of 8 km² with a 5 m range holds 279 MWh per emptying; with about 705 tides a year and 25 % conversion that is 49 GWh. Energy grows with the square of the range, so barrages pay only where the range is large.
How do geothermal and biogas plants make power?
A geothermal plant drills into hot rock: hot water from the well flashes to steam in a separator at lower pressure, or heats a low-boiling fluid in a binary cycle, and the steam drives a turbine; the cooled brine is pumped back down. Biogas plants digest dung, food waste or crop residue without air; the gas, mostly methane, fires an engine or boiler. India's bio-power capacity (CEA's biomass and bagasse cogeneration category) was 10,869 MW on 31 October 2026 (CEA). The Renewable Energy book models geothermal flash and biogas yields.
How does a fuel cell power plant work?
A fuel cell burns hydrogen without a flame: hydrogen splits at the anode, protons cross the electrolyte, and electrons flow through the outside circuit to the cathode, where they meet oxygen and form water. NIST's formation data give a reversible cell voltage of 1.229 V; real cells typically run at 0.6-0.8 V, so stacks join hundreds in series. At 50 % efficiency on hydrogen's lower heating value (120 MJ/kg) a megawatt-hour needs 60 kg of hydrogen. The Electric Vehicles book plots the polarisation curve.
A 300 MWp solar plant and a 200 MW wind farm share a 250 MW connection at Jodhpur. What share of their energy is curtailed over a year?
The model curtails only 0.5 %. Both sources reach their peaks at different hours and seasons: the sum touched 250 MW only around noon in the windy months (in May the peak hour reaches 276 MW and 81 MWh a day is clipped). Sharing one connection is why hybrids are cheaper to connect.
Worked examples
Capacity utilisation factor of a hybrid connection · Jodhpur model (Renewable Energy book): 300 MWp PV gives 524.9 GWh/yr, 200 MW wind gives 631.8 GWh/yr; 0.48 % is clipped at a 250 MW connection
- Solar CUF = 524.9/(300 × 8.76) = 20 %; wind CUF = 631.8/(200 × 8.76) = 36.1 %
- Delivered = (524.9 + 631.8) × (1 − 0.00483) = 1151.1 GWh
- Connection CUF = 1151.1/(250 × 8.76) = 52.6 %
- With a 500 MW line nothing clips, but CUF = 1156.7/(500 × 8.76) = 26.4 %
- MNRE test: 200/300 = 66.7 % ≥ 25 %: a hybrid
Answer: 52.6 % on the 250 MW line, about twice the 26.4 % of a full-size line, for 0.5 % lost energy
Clipping hour by hour · Six afternoon hours (original): solar 40, 90, 110, 95, 50, 0 MW; wind 30, 25, 20, 30, 45, 70 MW; connection 120 MW
- Total each hour: 70, 115, 130, 125, 95, 70 MW
- Above 120 MW: 0, 0, 10, 5, 0, 0 MW, so 15 MWh is curtailed
- Delivered = 605 − 15 = 590 MWh
- Share curtailed = 15/605 = 2.5 %
Answer: 15 MWh clipped (2.5 %); 590 MWh delivered
Energy from a tidal basin · Basin 8 km² (original), mean range 5 m, sea water 1,025 kg/m³, one generation per tide (ebb), conversion 25 % (assumed)
- Energy per emptying = ρ g A R²/2 = 1,025 × 9.81 × 8×10⁶ × 5²/2 = 1.005×10¹² J = 279 MWh
- Tides a year = 365 × 24/12.42 = 705.3
- Ideal yearly energy = 279 × 705.3 = 196.9 GWh
- At 25 %: 49.2 GWh, an average of 5.6 MW
Answer: About 49 GWh a year: halve the range and it falls four times
Load curves and load-distribution parameters, and choosing base-load and peak-load plants
Which syllabus covers thisAU CME384 Unit V (load distribution parameters, load curve)VTU not in syllabusSPPU 402049 Unit 5 (load curves, load division)MU not in syllabusKTU PEMET631 Module 4 (load curve, load, diversity, capacity and use factors)
What do load factor, demand factor, diversity factor and plant capacity factor measure?
Connected load is the sum of every rating on the consumer side; maximum demand (MD) is the highest average load over a short interval. Demand factor = MD / connected load (below 1). Load factor = average load / MD: how flat the demand is. Diversity factor = sum of the individual MDs / the combined MD (above 1, because consumers peak at different times). Plant capacity factor = energy made / (installed capacity × 8,760 h); plant use factor uses the hours the plant actually ran. The book's original 20 GW system averages 15,175 MW: a load factor of 75.9 %. The Power Systems book builds a daily feeder curve from three consumer classes.
What is a load duration curve and why do planners use it instead of the daily curve?
Take all 8,760 hourly loads of a year and sort them from highest to lowest. The result is the load duration curve (LDC): read across at any MW and it tells you how many hours a year the load is above that level. Its area is the year's energy, 132.9 TWh for the book's original system. The bottom 11,561 MW is needed every hour of the year; the top 2 GW (above 18 GW) is needed for only 484 hours and holds just 0.34 % of the energy. That shape, not the hour of day, decides which plant should serve which slice.
How do screening curves pick the cheapest plant for each slice of load?
Plot the yearly cost of 1 kW of each plant against the hours it runs: a straight line, fixed cost (capital annuity + fixed O&M) plus fuel cost × hours. At 10 % over 25 years, coal at CEA's ₹7.85 crore/MW costs ₹10,448/kW·yr fixed and ₹2.07/kWh to fuel from THE PLANT's heat rate; an open-cycle gas turbine costs ₹4,656/kW·yr and ₹8.11/kWh. The lines cross at 959 hours. Below that, the cheap-to-build, dear-to-run peaker wins; above it, coal. The lowest line at each running time is the envelope.
How do break-even hours turn into megawatts of each plant type?
Draw the break-even hours down onto the LDC. Load needed for fewer than 896 hours goes to open-cycle gas turbines: 2.7 GW. A thin 100 MW slice suits combined cycle, 1.6 GW suits coal, and the 15.6 GW that runs more than 3,250 hours goes to nuclear at CEA's 2021-22 PHWR cost. The system then costs ₹2.85/kWh. Screening curves ignore availability (CEA: nuclear 68 %, new coal 88 %), 6-year builds, fuel limits and reserve. With availability counted, nuclear beats coal only above 7,643 h, close to the full year.
What decides the number and size of units in a station?
Big units are cheaper per MW and more efficient, but the largest unit sets the reserve: if it trips, the rest must cover it. A 660 MW unit is 3.3 % of the original system's 20 GW peak, so a 15 % reserve margin needs about 35 such units' worth of capacity in all. Several identical units share spares and let one be overhauled while the others run. Base-load plants (coal, nuclear) want high load factor and slow changes; peak-load plants (gas turbines, hydro, pumped storage, diesel) must start fast and accept low running hours. Adding 8 GW of solar (CUF 22.7 %) drops the minimum load to 6,581 MW but leaves the evening peak at 20 GW.
Your system's peak will grow by 1 GW, but that extra load lasts only about 200 hours a year. Which plant should you build for it?
Run 200 hours a year, 1 kW of OCGT costs ₹4,656 + ₹8.11 × 200 = ₹6,278/kW·yr; coal costs ₹10,448 + ₹2.07 × 200 = ₹10,862. 200 h is far below the 959 h break-even: cheap capital beats cheap fuel.
Worked examples
Demand, load, diversity and plant capacity factors of a captive plant · A 30 MW captive plant (original case) supplies three factories: connected loads 20, 15 and 10 MW, maximum demands 12, 9 and 7 MW; their combined maximum demand is 22 MW; the plant sends out 120 GWh a year and runs 7,500 h
- Demand factors: 12/20 = 0.6, 9/15 = 0.6, 7/10 = 0.7
- Diversity factor = (12 + 9 + 7)/22 = 1.273
- Load factor = 120,000 MWh / (22 MW × 8,760 h) = 62.3 %
- Plant capacity factor = 120,000 / (30 × 8,760) = 45.7 %; plant use factor = 120,000 / (30 × 7,500) = 53.3 %
- Reserve capacity = 30 − 22 = 8 MW
Answer: Diversity 1.27, load factor 62.3 %, plant capacity factor 45.7 %, use factor 53.3 %
Break-even hours between coal and an open-cycle gas turbine · Coal: ₹7.85 crore/MW, 25 years, O&M ₹18 lakh/MW·yr, fuel ₹2.069/kWh. OCGT: ₹3.5 crore/MW (assumed), 25 years, O&M ₹8 lakh/MW·yr, fuel ₹8.109/kWh. Discount rate 10 %
- Capital recovery factor (10 %, 25 years) = 0.1 × 1.1²⁵/(1.1²⁵ − 1) = 0.11017
- Coal fixed: 78,500 ₹/kW × 0.11017 + 1,800 = ₹10,448/kW·yr
- OCGT fixed: 35,000 × 0.11017 + 800 = ₹4,656/kW·yr
- h* = (10,448 − 4,656) / (8.109 − 2.069) = 959 h
- At h*, both cost ₹12,433/kW·yr
Answer: About 959 hours a year: load needed for less than that should be met by gas turbines
Megawatts of each plant type from the load duration curve · The original 20 GW system's LDC and the envelope's break-even hours 896, 998 and 3,250 h (OCGT → CCGT → coal → nuclear)
- Read the LDC at each break-even time: 17,293, 17,194 and 15,585 MW
- Peak band (OCGT): 20,000 − 17,293 = 2,707 MW
- CCGT: 17,293 − 17,194 = 100 MW; coal: 17,194 − 15,585 = 1,609 MW
- Base band (nuclear): everything below 15,585 MW = 15,585 MW, making 96.8 % of the energy
- OCGT makes only 934 GWh a year from 2.7 GW: about 345 full-load hours
Answer: OCGT 2.71 GW, CCGT 0.1 GW, coal 1.61 GW, nuclear 15.58 GW (screening only; reserve and availability come on top)
Cost of electricity: capital and operating costs, depreciation and cost per kWh
Which syllabus covers thisAU CME384 Unit V (capital and operating cost)VTU not in syllabusSPPU 402049 Unit 5 (fixed and operating cost, depreciation)MU not in syllabusKTU PEMET631 Module 4 (economics of generation, useful life)
How much does it cost to build each kind of power plant in India?
CEA's generation-mix study (2021-22 prices) assumed, per MW: pithead supercritical coal ₹7.85 crore including FGD (load-centre ₹7.60), nuclear PHWR ₹11.70 crore and imported light-water reactors ₹19 crore, solar ₹4.50, wind ₹6, hydro ₹5.5 to 28 crore by site. Fixed O&M: ₹18 lakh/MW·yr for coal, ₹20 lakh for nuclear. Running (fuel) cost per kWh flips the order: new pithead coal ₹1.63-2.65, existing gas ₹2.42-3.52, nuclear ₹0.85. One crore is 100 lakh, ₹10 million. THE PLANT at ₹7.85 crore/MW costs ₹5,181 crore.
Which costs are fixed and which are running costs?
Fixed costs are paid whether the unit runs or not: interest on the money, depreciation, fixed O&M (staff, maintenance), insurance and taxes. For THE PLANT at 10 %: interest ₹518 crore, sinking-fund depreciation ₹47 crore, O&M ₹119 crore, insurance (0.5 %, assumed) ₹26 crore: ₹710 crore a year. Running cost is mostly coal: 0.591 kg per kWh sent out (net heat rate 9,407 kJ/kWh ÷ GCV 15,910 kJ/kg) at ₹3,500/t landed (assumed; CIL's G12 pithead price is ₹896/t before taxes and freight) = ₹2.07/kWh.
What are the straight-line, sinking-fund and diminishing-balance methods of depreciation?
All three recover (capital − salvage) over the life; they differ in timing. Straight line charges the same amount every year: for THE PLANT, (₹5,181 − ₹518 crore)/25 = ₹186.5 crore. Sinking fund puts a smaller equal sum into a fund that earns interest: ₹47.4 crore a year at 10 % grows to ₹4,663 crore in 25 years. Diminishing balance writes off a fixed fraction, here 8.8 %, of what is left: ₹456 crore in year 1, little at the end. CERC uses straight line at 4.22 %/yr for new plant to 90 %.
Why does the cost of a unit of electricity rise when the plant runs less?
The fixed ₹710 crore a year has to be shared by however many kWh the unit sends out. At the book's 75 % load factor that is 4.08 billion kWh, so fixed cost is ₹1.74/kWh and the total ₹3.81/kWh. At 85 % (CERC's normative availability) it falls to ₹3.61; backed down to 30 % for solar hours, it climbs to ₹6.43. Fuel per kWh stays about the same (here exactly; really it rises a little at part load). This is why base-load plants are built to run hard.
How does CERC turn these costs into a two-part tariff?
CERC's 2024 rules split the price. The capacity charge recovers the annual fixed cost (return on equity 15.5 %, interest on loan, depreciation, interest on working capital, O&M) and is paid in proportion to availability, against 85 % normative. The energy charge recovers fuel: ECR = SHR × coal price / (GCV − 85) × 100/(100 − AUX). For THE PLANT, the design gross heat rate 2,112 kcal/kWh × 1.045 gives a normative 2,207 kcal/kWh; with ₹3.5/kg coal of 3,800 kcal/kg and 5.25 % auxiliary power, ECR = ₹2.19/kWh sent out (secondary oil ignored).
THE PLANT's load factor falls from 75 % to 50 %. Its cost per kWh sent out rises from ₹3.81 to about…
Only the fixed part, ₹1.74/kWh, is spread over fewer kWh: × 75/50 = ₹2.61. Fuel stays ₹2.07. Total ₹4.68/kWh, 23 % more, not 50 %.
Worked examples
Depreciation of a station by three methods · An original 2 × 125 MW station costs ₹1,200 crore, salvage 10 % (₹120 crore), life 25 years, interest 8 %
- Straight line: (1,200 − 120)/25 = ₹43.2 crore a year; book value after 10 years = 1,200 − 10 × 43.2 = ₹768 crore
- Sinking fund: annual deposit = 1,080 × 0.08/(1.08²⁵ − 1) = ₹14.77 crore; fund after 10 years = 14.773 × (1.08¹⁰ − 1)/0.08 = ₹214 crore; book value ₹986 crore
- Diminishing balance: r = 1 − (120/1,200)^(1/25) = 8.8 %; first-year charge ₹105.6 crore; book value after 10 years = 1,200 × (1 − 0.088)¹⁰ = ₹477.7 crore
- All three reach ₹120 crore at year 25
Answer: Book value after 10 years: ₹768 crore (SL), ₹986 crore (SF), ₹478 crore (DB)
Cost per kWh of THE PLANT at 75 % load factor · 660 MW gross, 6 % auxiliary power, ₹7.85 crore/MW, 10 % interest, 25 years, salvage 10 %, sinking fund, O&M ₹18 lakh/MW·yr, insurance 0.5 %, net heat rate 9,407 kJ/kWh, coal GCV 15,910 kJ/kg at ₹3,500/t
- Capital P = 7.85 × 660 = ₹5,181 crore; interest 10 % = ₹518.1 crore
- Sinking fund deposit = 4,663 × 0.1/(1.1²⁵ − 1) = ₹47.41 crore; O&M ₹118.8 crore; insurance ₹25.91 crore
- Fixed cost = ₹710.2 crore a year
- kWh sent out = 660,000 kW × 8,760 h × 0.75 × 0.94 = 4.076 × 10⁹; fixed ₹1.742/kWh
- Fuel = 9,407/15,910 × 3.5 = ₹2.069/kWh
Answer: ₹3.81 per kWh sent out (₹1.74 fixed + ₹2.07 fuel)
Energy charge rate the CERC way · THE PLANT's design gross heat rate 2,112 kcal/kWh, coal 3,800 kcal/kg as received at ₹3,500/t landed, auxiliary power 5.25 % (steam-driven feed pumps), secondary fuel oil ignored
- Normative station heat rate SHR = 1.045 × 2,112 = 2,207 kcal/kWh (units of 500 MW and above)
- CVPF = 3,800 − 85 = 3,715 kcal/kg (CERC's allowance for storage loss)
- Coal per kWh generated = 2,207/3,715 = 0.5941 kg; cost ₹2.079/kWh
- Per kWh sent out: × 100/(100 − 5.25) = ₹2.194/kWh
Answer: ECR ≈ ₹2.19/kWh, a little above the ₹2.07 fuel cost at the design heat rate, because the norm allows 4.5 % more heat
Power tariffs: flat, block, two-part, maximum demand, power factor and time-of-day tariffs
Which syllabus covers thisAU CME384 Unit V (power tariff types)VTU not in syllabusSPPU 402049 Unit 5 (tariff, analysis of energy bill)MU not in syllabusKTU PEMET631 Module 4 (tariff for electrical energy)
What should a tariff do?
A tariff must recover what supply costs: the fixed cost of plant, wires and staff (which grows with how many kW you might draw) and the running cost (which grows with kWh). It should be simple enough to read on a bill, fair between consumer classes, and it should push consumers towards behaviour that lowers system cost: a steady load (high load factor), a good power factor, and use when power is cheap. Chapter 26's two-part generation price, capacity charge plus energy charge, is the same idea one step up the chain.
How do the common tariffs differ, and which suits whom?
Flat rate: one price per kWh. Block rate: the price changes as monthly kWh cross set blocks. Two-part: a charge per kW connected plus a price per kWh. Maximum demand: the kW part is billed on the MD actually measured, often in kVA. Power factor: a penalty or incentive on the bill for pf below or above a threshold. Time of day (ToD): the kWh price depends on the hour. For the original small industry (47,280 kWh a month, all rates assumed), bills run from ₹3,37,320 (two-part) to ₹4,47,760 (block, built for homes).
What are Hopkinson's two-part and Doherty's three-part tariffs?
Hopkinson's two-part tariff charges for the capacity you could draw (₹ per kW connected or of maximum demand) and separately for the energy you use (₹ per kWh): it mirrors the supplier's fixed and running costs. For the original commercial building: 400 kW × ₹200 = ₹80,000 plus 1,20,450 kWh × ₹6.5 = ₹7,82,925, so ₹7.16/kWh against ₹8 flat. Doherty's three-part tariff adds a fixed charge per consumer for metering and billing, here an assumed ₹500 a month. A high load factor spreads the demand charge thin.
Why do utilities charge for poor power factor, and how fast does correction pay back?
At low pf the same kW needs more current, so cables, transformers and generators carry more kVA. The small industry draws 98 kW at pf 0.82, which is 119.5 kVA; at 0.95 it would be 103.2 kVA. Under the assumed pf clause (1 % per 0.01 below 0.90) it pays ₹27,722 a month extra. Capacitors of Q = P(tan φ₁ − tan φ₂) = 36.2 kVAr, at an assumed ₹1,000/kVAr (₹36,193), lift pf to 0.95, where the clause is neutral: payback in about 1.3 months.
What is a time-of-day tariff and why did India bring it in?
Solar plants flood the grid at midday, and the evening peak must be met by coal and gas after sunset. The Ministry of Power's 2023 rules make the ToD tariff 10-20 % lower in the 8 solar hours and 10-20 % higher at peak; commercial and industrial consumers with 10 kW or more demand got it from 1 April 2024 (PIB). The original commercial building, busy at midday, saves ₹56,784 a month at 20 % each way; moving 40 % of its peak-hour kWh into solar hours lifts that to ₹80,028, though its MD rises from 300 to 337 kW. The evening-heavy home pays ₹70 more.
A home uses most of its electricity in the evening. It moves to a ToD tariff: 20 % cheaper in solar hours, 20 % dearer from 18:00 to 22:00. Its monthly bill…
Only 120 of its 608 kWh fall in the solar hours but 174 kWh fall at peak. With the same demand charge, the ToD bill is ₹4,735 against ₹4,665: ₹70 more, unless it shifts its load.
Worked examples
Two-part (Hopkinson) bill for a commercial building · Original office-and-retail building: connected load 400 kW, 4,015 kWh a day for 30 days, maximum demand 300 kW; tariff ₹200 per kW connected per month + ₹6.5/kWh (assumed rates)
- Energy = 4,015 × 30 = 1,20,450 kWh
- Demand part = 400 × 200 = ₹80,000; energy part = 1,20,450 × 6.5 = ₹7,82,925
- Bill = ₹8,62,925; on a flat ₹8/kWh it would be ₹9,63,600
- Load factor = 4,015/(24 × 300) = 55.8 %; effective price ₹7.16/kWh
- Three-part (Doherty) with an assumed ₹500 consumer charge: ₹8,63,425
Answer: ₹8,62,925 a month, ₹7.16 per kWh
Block-rate bill for a home · Original 2-BHK home: 20.25 kWh a day for 30 days; blocks ₹4.5 for the first 100 kWh, ₹6.5 for the next 200, ₹8.0 for the next 200, ₹9.5 above 500 (assumed)
- Energy = 20.25 × 30 = 607.5 kWh
- First 100 kWh × 4.5 = ₹450; next 200 × 6.5 = ₹1,300
- Third block 200 × 8.0 = ₹1,600; the remaining 107.5 kWh × 9.5 = ₹1,021.25
- Total ₹4,371.25; average ₹7.2/kWh against ₹8 flat
Answer: ₹4,371 a month; the last kWh costs ₹9.5, the average ₹7.2
Power factor penalty and the capacitor that removes it · Original small industry: maximum demand 98 kW at pf 0.82, 47,280 kWh a month; ₹400 per kW of MD + ₹6.5/kWh, +1 % per 0.01 below 0.90, −0.5 % per 0.01 above 0.95 (assumed); capacitors ₹1,000/kVAr (assumed)
- Base bill = 400 × 98 + 6.5 × 47,280 = ₹3,46,520
- pf 0.82 is 8 hundredths below 0.90: penalty 8 % = ₹27,722
- Capacitor for 0.95: Q = 98 × (tan(cos⁻¹ 0.82) − tan(cos⁻¹ 0.95)) = 98 × (0.698 − 0.3287) = 36.2 kVAr
- Cost ₹36,193; at 0.95 the clause is neutral, so the saving is ₹27,722 a month
- Under a kVA maximum-demand tariff the same capacitor cuts MD from 119.5 to 103.2 kVA: ₹6,542 a month
Answer: Penalty ₹27,722 a month; a 36 kVAr capacitor pays back in about 1.3 months
Pollution control: electrostatic precipitators, FGD, NOx control, emission norms and site selection
Which syllabus covers thisAU CME384 Unit V (pollution control, waste disposal, site selection)VTU not in syllabusSPPU 402049 Unit 2 (pollutants, scrubbers, ESP)MU not in syllabusKTU PEMET631 Module 4 (control of particulate matter and SO2)
What does a coal unit put into the air, water and land?
At full load THE PLANT burns 101.9 kg/s of coal with 38 % ash: 3,345 t of ash a day. Leaving the boiler, the flue gas carries 55,682 mg/Nm³ of fly ash and 1,821 mg/Nm³ of SO2 (6 % O2 basis), plus NOx from hot flames and nitrogen in the coal, traces of mercury, and 12,961 t of CO2 a day. The condenser rejects 740 MW of heat into cooling water (thermal pollution). Ash goes to cement, bricks, roads and ponds: India used 332.63 Mt of the 340.11 Mt generated in 2024-25 (PIB).
What are India's emission norms for coal units, and why are they quoted at 6 % O2?
MoEFCC's notification S.O. 3305(E) of 7 December 2015 sets, for units installed from 2017: PM 30, SO2 100, NOx 100 and mercury 0.03 mg/Nm³; for 2004-2016 units PM 50, SO2 200 (500 MW and above), NOx 300. Values are dry and corrected to 6 % O2 so that diluting with air cannot hide emissions: C₆ = C × (21 − 6)/(21 − O2). THE PLANT's gas has 3.55 % O2, so the factor is 0.8597. Meeting the norms needs 99.95 % dust capture and 94.5 % SO2 removal. Since July 2025 the SO2 limit applies by location category (A, B; C needs only stack height).
How does an electrostatic precipitator work, and how big must it be?
High-voltage wires charge the dust; the charged particles drift to earthed plates at the migration velocity w and are rapped into hoppers. The Deutsch-Anderson equation gives efficiency from plate area A and gas flow Q. THE PLANT sends 791 m³/s at 140 °C; for 30 mg/Nm³ at w = 4 cm/s (assumed for Indian ash) it needs SCA = A/Q = 188 s/m, about 149 thousand m² of plates. Low-sulphur Indian ash is highly resistive and causes back corona: EPA lists 2-3 cm/s then, against 8-13 cm/s for ordinary fly ash. Bag filters are the alternative.
How are SO2 and NOx removed?
Wet limestone FGD sprays limestone slurry into the gas: CaCO3 + SO2 + ½O2 + 2H2O → CaSO4·2H2O + CO2. At 96 % removal THE PLANT uses 155 t of 85 %-pure limestone a day, 9.8 g/kWh, matching CERC's normative 9.78 g/kWh, and makes 227 t of gypsum; the FGD takes about 1 % of output. NOx: low-NOx burners with over-fire air hold about 450 mg/Nm³ (CEA, as reported by TERI); SNCR (urea, 25 % median on US coal units, EPA) gives about 338; SCR (ammonia over a catalyst) reaches 90 at an assumed 80 %.
How do coal, hydro, nuclear and gas plants compare on siting and CO2?
Coal: water, a rail or conveyor coal link, land for ash, distance from cities. Hydro: head and catchment, but villages and forest may be flooded. Nuclear: an exclusion zone, low seismicity and cooling water. Gas: a pipeline, and it can sit near load. CO2 per kWh sent out: THE PLANT 0.88 kg (with FGD), against 0.85 kg from CEA's 90.6 g/MJ coal factor; a 55 % combined cycle about 0.32 kg (CEA gas factor 49.4 g/MJ); hydro, nuclear, wind and solar almost nothing at the plant. India's grid averaged 0.675 kg/kWh in 2025-26 (CEA).
Indian coal ash is low in sulphur. Compared with high-sulphur coal ash, the ESP needed to reach 30 mg/Nm³ is…
Little SO3 in the gas leaves the ash highly resistive, so a layer on the plates causes back corona and the migration velocity collapses (EPA: about 2.5 against 10 cm/s). For THE PLANT's dust, SCA = ln(55,682/30)/w rises from 75 to 301 s/m: 4 times the plate area.
Worked examples
ESP collection area for THE PLANT · Dust leaving the boiler 55,682 mg/Nm³ (6 % O2), target 30 mg/Nm³, gas flow 791 m³/s at 140 °C, migration velocity 4 cm/s
- Required efficiency η = 1 − 30/55,682 = 99.946 %
- Penetration p = 1 − η = 5.388 × 10⁻⁴; ln(1/p) = 7.526
- SCA = ln(1/p)/w = 7.526/0.04 = 188.2 s/m
- Plate area A = SCA × Q = 188.2 × 790.7 = 148,777 m²
- At w = 3 cm/s the same target needs 251 s/m
Answer: About 149 thousand m² of collecting plate (SCA 188 s/m)
SO2 from the coal's sulphur, the FGD it needs and its limestone · THE COAL: S 0.5 %, 4.717 Nm³ dry flue gas per kg at 3.55 % O2; coal 101.89 kg/s; norm 100 mg/Nm³; FGD 96 %, Ca/S 1.0, limestone purity 85 %
- S + O2 → SO2: 0.005 × 64.06/32.06 = 9.99 g SO2 per kg coal
- At measured O2: 2118 mg/Nm³; × (21 − 6)/(21 − 3.55) = 1,821 mg/Nm³ at 6 % O2
- Removal needed for 100 mg/Nm³: 1 − 100/1,821 = 94.5 %; at 96 % the stack shows 73 mg/Nm³
- Sulphur captured = 101.89 × 0.005 × 0.96 = 0.4891 kg/s; limestone = × 100.09/32.06/0.85 × 86.4 = 155 t/day
- Gypsum = 0.4891 × 172.17/32.06 × 86.4 = 227 t/day
Answer: 94.5 % removal is the minimum; a 96 % FGD uses 155 t of limestone a day
Correcting a stack reading to 6 % oxygen · An analyser reads 85 mg/Nm³ SO2 (dry) at 8.2 % O2 on a unit with a 100 mg/Nm³ limit (original reading)
- Extra air dilutes the gas, so the reading must be brought to the reference oxygen
- C₆ = 85 × (21 − 6)/(21 − 8.2) = 85 × 15/12.8 = 99.6 mg/Nm³
- The corrected value is 17.2 % higher than the raw reading
- Against the 100 mg/Nm³ limit: 99.6 leaves almost no margin
Answer: 99.6 mg/Nm³ at 6 % O2: just inside the limit, though the raw 85 looked comfortable
Keep going
- Thermal Engineering interactive book
- Turbomachinery interactive book
- Renewable Energy interactive book
- Rankine cycle calculator
- Air preheat fuel savings calculator
- All Skill-Lync interactive books
Recommended reading
- Power Plant Engineering, P. K. Nag
- Power Plant Technology, M. M. El-Wakil
- A Textbook of Power Plant Engineering, R. K. Rajput
- A Course in Power Plant Engineering, S. C. Arora and S. Domkundwar
- Steam: Its Generation and Use, Babcock & Wilcox
- Nuclear Reactor Engineering, S. Glasstone and A. Sesonske
How this book was made
Chapters follow the official syllabi listed above. Every interactive's formulas and every worked-example number were checked by script. Explanations, animations and examples are original to Skill-Lync. Topics informed by MIT OpenCourseWare 2.60J (Fundamentals of Advanced Energy Conversion), CC BY-NC-SA. All explanations, animations and examples are original to Skill-Lync; MIT does not endorse this page.