Wiring harness routing & packaging Rules Week 3 Challenge
P_CLAMP:
The clip is a support part in the electrical part family.They may or may not be available in standard.To define a clip following steps has to be follwed:
- Download the part
- Define the part as support
- Add the geometrical parameters
- Define the entry and exit point for the support
- Define the base plane
CREATE GEOMETRICAL PARAMETERS

DEFINE AS SUPPORT

DEFINE THE ENTRY POINT

DEFINE THE EXIT POINT

BACKSHELL:
To define the Backshell the follow the below steps:
- Download the part
- Create the gemetrical parameters (point and backshell axis)
- Define the backshell connection point
- Defone the bundle entry point
DEFINE THE PART

DEFINE THE BACKSHELL AXIS

DEFINE THE BACKSHELL CONNECTION POINT

DEFINE THE BUNDLE ENTRY POINT

COT TUBES:
COT TUBES/CORRUGATED TUBES/CONVOLUTED TUBES CAN BE DESIGNED BY USING DEFINE PROTECTIVE PART COMMAD IN ELECTRICAL PART DESIGN.ALL COT TUBES ARE SAVED IN SLIT_COT CATALOGE AS SHOWN BELOW:
TO DEFINE THE NEW COT TUBE

ENTER THE VALUES TO CREATE COT TUBES

5MM_COT

10 MM_COT

15MM_COT

20MM_COT