Challenge

Week 6: Conjugate Heat Transfer Simulation

Conjugate Heat Transfer

The term conjugate heat transfer (CHT) is used to describe processes which involve variations of temperature within solids and fluids, due to thermal interaction between the solids and fluids. The exchange of thermal energy between the two physical bodies is called study of Heat Transfer, the rate of transferred heat is directly proportional to the temperature difference between the bodies. This corresponds with the combination of heat transfer in solids and heat transfer in fluids. In solids, conduction often dominates whereas in fluids, convection usually dominates. Efficiently combining heat transfer in fluids and solids is the key to designing effective coolers, heaters, or heat exchangers. Forced convection is the most common way to achieve high heat transfer rate. In some applications, the performances are further improved by combining convection with phase change for example liquid water to vapor phase change.

Heat transfer in solids and heat transfer in fluids are combined in the majority of applications. This is because fluids flow around solids or between solid walls, and because solids are usually immersed in a fluid.

Aim

To perform a Conjugate Heat Transfer Simulation through a pipe with grid dependancy test and varing supercycle stage intervals.

Calculations for Velocity

Re= 7000

Dynamic Viscosity - 1.81*10^-5 `(kg)/(ms)`

Density- 1.225 `(kg)/m^3`

Diameter- 0.03 m.

Re = (rho*V*D)/(Dynamic viscosity)

V=`(7000*1.81*10^-5)/(1.225*0.003)`

V= 3.447 m/s.

Geomerty

Above is the geometry that isused for the CHT simulation.

Boundary Conditions

Soild_outer_wall

Velocity BC- Wall Motion type-Stationary, Surface movement-Fixed

Temperature BC- Heat Flux- -1000 `W/m^2`

Solid_side

Velocity BC- Wall Motion type-Stationary, Surface movement-Fixed

Temperature BC- Zero Normal Gradient

Inlet

Pressure BC- Zero Normal Gradient

Velcity BC- 3.447 m/s

Temperature BC- 300 K

Outlet

Pressure BC- 101325 Pa

Velocity BC- Zero Normal Gradient

Interface

Velocity BC

Forward

Region- Fluid Region

Wall Treatment- Law of Wall

Temperature BC- Law of Wall coupled

Reverse

Region- Solid Region

Wall Treatment- Slip

Temperature BC- Specified Value Coupled

Region and Initialization

Fliud Region

Temperature- 300 K

Pressure- 101325 Pa

Species- O2 and N2

Solid Region

Temperature- 300 K

Species- Aluminum.

Super-Cycle Modelling

For Grid Dependancy test the super-cycle stage interval is set to 0.05 seconds.

Then for the variations the intervals are set to 0.01 sec ,0.02 sec and 0.03 sec.

Base Grid

For Grid Dependancy test the grid size is set to 0.004 m base grid size, 0.003 m and 0.002 m.

Then for the super-cycle intervals the grid size is set to 0.004 m that is base grid size.

Grid Test

Below are the meshs of the varing grid size from 0.004m to 0.002m.

Base Grid of 0.004 m

Grid Size of 0.003 m

Grid Size of 0.002 m

Cell Count of the Meshs

Above is the cell count for the varing grid sizes.The largest is for the 0.002m grid size which is above 36000 cell count.

Temperature Plots

Above plot is the Temperature Plot at the outlet. Maximum temperature at the outlet is for the base grid which is almost at 900 K and the finer grid has temperature of 750 K at the outlet.

Temperature Contours of different Grids

Base Grid

0.003m Grid

0.002 m Grid

In the above graphs of different grid sizes the heat transfer rate varies differently with respect to the grids meaning the heat follow rate is more smother and clearer in the 0.002 m grid size when comparing to other grid sizes. The tempeature is more at the outlet raning in between 500 to 600 K.

Y+ Contours

When looking at the Y+ contours we can see a turbulent region for the 0.004 m and 0.003 m meshes are extending from the inlet region till the middle region meaning it has greater value of Y+ more than 30. But in the finer mesh case the laminar region is in the begining meaning the case is more refined when compated to the other two grid sizes and also the Y+ values is in the Laminar regions.

Super-Cycle Intervals

0.01 Interval

0.02 Interval

0.03 Interval

Above are the temperature plots with 0.004 m grid size with varing interval of supercycle stages. The temperature of the grids are same throughout the cases with minimum temperature of 300 K at the inlet to a max temperature of 700 K within the solid and for the solid walls the temperature is about 850K.

Super-Cycle Plot

Above the supercycle plot where the temperature converges 650 K for all the intervals at the end of the simulation.

Y+ Contour

The Y+ contour for this case irrespective of the intervals are the same at the begining the region is turbulent but as it progressed the region is in laminar at the end of the simulation.

Simulation Time

Super-Cycle Interval

SGS Simulation Time(sec)
0.01 319.766577 s
0.02 346.576104 s
0.03 351.808274 s

Grid Size

Grid Size (m) Simulation Time(sec)
0.004 398.281962 s
0.003 1193.781407 s
0.002 5840.229973 s

Conclusion

From the simulation we can see that varing the grid size varies the temperature distribution and Y+ function is also varies.

In terms of simulation time finer the mesh longer the simulation time and also the simulation time varies with the SGS parameter.

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.