Week - 4
- Implement control logic of a “washing machine” using State flow as per given sequence:
If the power supply is available, the system gets activated
If the Water supply is not available, stop the process & indicate through LED
Soaking time should be 200s followed by washing time of 100s.
Then rinsing happens for next 20s & dryer runs for 50s
After all the processes have completed turn on the finished LED
Simulation model:
Chart in state flow:
Condition-1: Power supply = OFF, Water Level = OFF
Result:
|
Power Supply |
Water Level |
Soaking |
washing |
rinsing |
dryer |
End |
|
OFF |
Empty |
OFF |
OFF |
OFF |
OFF |
OFF |
Condition-2: Power supply = ON, Water Level = Empty
Result:
|
Power Supply |
Water Level |
Soaking |
washing |
rinsing |
dryer |
End |
|
ON |
Empty |
OFF |
OFF |
OFF |
OFF |
OFF |
Condition-3: Power supply = ON, Water Level = ON
Result:
|
Power Supply |
Water Level |
Soaking |
washing |
rinsing |
dryer |
End |
|
ON |
Filled |
ON |
ON |
ON |
ON |
ON |
- Make a Simulink chart for the “Gear shift” logic as per below conditions:
Speed Range (kmph) Gear
0 to 15 1
16 to 25 2
26 to 40 3
41 to 60 4
Above 61 5
Give speed input while the simulation is running & display the gear number.
Condition-1: Speed = 15
Result:
|
Speed |
Gear-1 |
Gear-2 |
Gear-3 |
Gear-4 |
Gear-5 |
|
15 |
X |
X |
X |
X |
Condition-2: Speed = 21
Result:
|
Speed |
Gear-1 |
Gear-2 |
Gear-3 |
Gear-4 |
Gear-5 |
|
21 |
X |
X |
X |
X |
Condition-3: Speed = 33
Result:
|
Speed |
Gear-1 |
Gear-2 |
Gear-3 |
Gear-4 |
Gear-5 |
|
33 |
X |
X |
X |
X |
Condition-4: Speed = 42
Result:
|
Speed |
Gear-1 |
Gear-2 |
Gear-3 |
Gear-4 |
Gear-5 |
|
42 |
X |
X |
X |
X |
Condition-5: Speed = 70
Result:
|
Speed |
Gear-1 |
Gear-2 |
Gear-3 |
Gear-4 |
Gear-5 |
|
70 |
X |
X |
X |