Challenge

Roof challenge

ROOF DESIGN USING NX CAD

1 INTRODUCTION

The roof is the top layer of the car, which protects the passengers from the sunlight, rain, and wind. The roof consists of a front roof rail, bow roof, center roof reinforcement, and rear roof rail. The bow roof is used in the flat section of the roof to give the support.

In the present challenge, a roof is modeled in NX CAD. Heat distortion criteria, snow load criteria, draft analysis, and section modulus calculation for different parts and the entire roof is being calculated.

2 PROCEDURE TO MODEL ROOF IN NX CAD

  1. The parent roof section is obtained from the styling department.
  2. A copy of the roof is taken to the midsection using OFFSET SURFACE with 0 mm distance and TRIM SHEET using the midplane.
  3. From the master section of the front roof rail, the front roof is designed precisely to use LAW EXTENSION, OFFSET SURFACE, and TRIM SHEET command. The front flange must be greater than 15 mm to accommodate the spot welding of the sheets.
  4. The bow roof - 1, center roof, and bow roof – 2 is designed as per the master sections using the OFFSET SURFACES, TRIM SHEET, STUDIO SURFACE, BRIDGE CURVES command.
  5. A gap of 0.5 mm is given between the outer roof and bow roofs for the mastic points.
  6. A rear roof is modeled the same as the master section given.
  7. For all the surfaces, a minimum angle of 7º is maintained for the punching to occur.
  8. FACE BLEND is used to smooth the faces.

3 DRAFT ANALYSIS

Using the DRAFT ANALYSIS command, the draft analysis is done for all the components. It is observed that the components are in acceptable green color.

Figure: Bow roof 1

Figure: Bow roof 2

Figure: Front roof rail

The yellow and blue region in the front roof rail suggests that the angle is less than `5^o`. The master section has a `3^o` angle there so it can be considered there.

Figure: Center roof reinforcement

Figure: Outer roof

Figure: rear roof rail

4 SECTION MODULUS

Section modulus calculation is done for all the individual parts and the whole roof part.

Figure: Outer roof

Figure: Bow roof 1

Figure: Bow roof 2

Figure: Rear roof rail

Figure: Front roof

Figure: Mid roof reinforcement

Figure: Entire roof

Table: Section modulus calculation

Table 1: Section modulus calculation of each section.

S. No

Section

Imax (mm4)

Imin (mm4)

y (mm)

Smax = `I_max/y`(mm3)

Smin = `I_min/y`(mm3)

1.

Front roof rail

1.5551E5

8.4161E3

114.2

1361.73

73.694

2.

Bow – 1

3.41986E4

367.197

80

427.4825

0.8399

3.

Center roof

4.19124E5

2.74264E3

120

3492.7

22.855

4.

Bow – 2

1.17159E5

591.54

120

976.325

4.9295

5.

Rear roof

2.50304E5

5.0695E3

149.2

1677.64

33.977

6.

Outer roof

6.10964E8

1.19898E6

1989.6

307078.80

602.623

7.

Entire roof

5.5726E9

1.34457E7

1989.6

2800864.49

6757.991

5 HEAT DISTORTION CRITERIA

The heat distortion criteria give the bow placement position on the roof. The formula to calculate heat distortion criteria is

1. `R_y` Calculation:

Figure: Front rail to Bow 1

Figure: Bow 1 to Centre roof

Figure: Center roof to Bow 2

Figure: Bow 2 to Rear roof

2. `R_x` Calculation:

Figure: Front rail to Bow 1

Figure: Bow 1 to Centre roof

Figure: Center roof to Bow 2

Figure: Bow 2 to Rear roof

2. `L_y` :

3. Formula

`W=(1.73*10^-3*L)+(1.85*10^-8*R^2/t)+(1.10*10^-3*l)-2.68`

Judgment condition must be `ok<2.7>3.1(NG)`

Where L = Length of the roof in the x-direction (o-y)

R = Roof curvature = `=(2*(R_x*R_y))/(R_x+R_y)`

t = roof thickness (mm)

l = Bow roof span (mm)

Table: Heat distortion criteria calculation

Table 2: Heat distortion criteria calculation
S.No Section L (mm) Rx (mm) Ry (mm) R (mm) t (mm) l (mm) W Ok/NG
1 FR-Bow1 1990.22 5835.43 2778.98 3764.981 0.75 440.9 1.597723 Ok
2 Bow1-CR 1990.22 4874.89 6517.81 5577.889 0.75 379.8 1.948311 Ok
3 CR-Bow2 1990.22 4004.93 11421.75 5930.415 0.75 377.9 2.046293 Ok
4 Bow2-Rear 1990.22 3303.79 16825.6 5523.093 0.75 309.7 1.856196 Ok

From Table 2, it is observed that the 'W' is in OK condition for all the sections, so the present roof model is acceptable.

6 SNOW LOAD CRITERIA

The snow load criteria are calculated using the following formula

`Q_r=(l_y*t^2)/(alpha*s*((R_x+R_y)/2)^2*10^-8`

Where `alpha=M_y*L_x^2*10^-2`

`M_y=y(L_y-y)`

Judgement condition = Qr ≥ 3.1

250 ≤ s ≤ 380

t = Roof plate thickness [mm]

Ly = Distance between the front and rear roof Rails on the Vehicle along with 0Y[mm]

Length of Roof panel with the center point between Roof rail Front /Rear as the reference point of the front and the rear.

Lx = Distance between the Left and Right end of the roof on the Roof BOW [mm]

Width of the roof panel exposed on the surface.

Y = Distance front Front Roof Rail to Roof BOW[mm]

s = Distance for which Roof BOW bears divided load [mm]

s = L1/2 + L2/2

Iy = Geometrical moment of inertia of Roof BOW (Y cross-section )[mm4]

Rx = Lateral direction curvature radius of roof panel Y cross-section on Roof BOW [mm]

Roof panel curvature Radius of the Length Lx in Front view

Ry = Longitudinal Direction curvature radius of the Roof panel X cross-section on Roof BOW [mm]

Roof panel X curvature radius of length s in Side view

1. Ry

2. Rx

Figure: Front rail to Bow 1

Figure: Bow 1 to Centre roof

Figure: Center roof to Bow 2

Figure: Bow 2 to Rear roof

3. S

4. Lx

Figure: Front rail to Bow 1

Figure: Bow 1 to Centre roof

Figure: Center roof to Bow 2

Figure: Bow 2 to Rear roof

5. Ly

From Table 3, the snow load criteria are calculated and it is observed that the results of Qr are in OK condition.

Table 3: Snow load criteria calculation
S.No Section ly (mm^4) t (mm) Ly (mm) y (mm) Lx (mm) My alpha L1 (mm) L2 (mm) s Rx Ry Qr Ok/NG
1 FR-Bow1 3.67E+02 0.75 1990.22 440.9 1132.87 683095.2 0.876681 533.1 479.6 506.35 4504.65 2592.34 3.695226 Ok
2 Bow1-CR 2.74E+04 0.75 1990.22 379.8 1083.57 611637.5 0.718138 479.6 498.4 489 3797.33 6475.41 166.5182 Ok
3 CR-Bow2 5.92E+02 0.75 1990.22 377.9 1057.28 609295.7 0.681096 498.4 444.7 471.55 4301.35 11386 4.156285 Ok
4 Bow2-Rear 0.00E+00 0.75 1990.22 309.7 1043.5 520457 0.566722 444.7 0 222.35 3925.04 367805.6 0

7 CONCLUSION

The roof is designed in NX CAD. The use of commands is studied. The calculation of heat distortion criteria and snow load criteria is done. All the snow load and heat distortion criteria results for the current roof are in OK condition. So the present roof is acceptable.

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.