Challenge

Project 2 - 3D CFD modelling of Air cooling system and liquid cooling system for battery thermal management

1. Understanding the System

  • Battery Module: 5 prismatic cells enclosed in an aluminum casing.
  • Cooling Types: Air cooling vs. Liquid cooling.
  • Worst-Case Scenario: Cells soaked at 45°C ambient temperature.
  • Heat Generation: Corresponding to 0.5C discharge rate.
  • Cooling Inlet Temperature: 20°C for both air and liquid.


2. Governing Equations

We need to analyze the heat transfer through conduction, convection, and possible radiation. The heat dissipation follows:

Heat Generation in the Cell

Heat generated per cell:

Qgen=I2RintQ_{\text{gen}} = I^2 R_{\text{int}}Qgen​=I2Rint​

where

  • III is the discharge current (calculated from 0.5C0.5C0.5C rate),
  • RintR_{\text{int}}Rint​ is the internal resistance of the cell.

Cooling Mechanisms

  • Air Cooling: Convective heat transfer with forced convection.qair=hairAΔTq_{\text{air}} = h_{\text{air}} A \Delta Tqair​=hair​AΔT
  • Liquid Cooling: Higher heat transfer coefficient hliqh_{\text{liq}}hliq​ due to better thermal conductivity.qliq=hliqAΔTq_{\text{liq}} = h_{\text{liq}} A \Delta Tqliq​=hliq​AΔT

where

  • hair≈20−50h_{\text{air}} \approx 20-50hair​≈20−50 W/m²K (depends on airflow speed),
  • hliq≈500−3000h_{\text{liq}} \approx 500-3000hliq​≈500−3000 W/m²K (depends on coolant type and flow rate),
  • AAA is the heat transfer surface area,
  • ΔT=(Tcell−Tcoolant)\Delta T = (T_{\text{cell}} - T_{\text{coolant}})ΔT=(Tcell​−Tcoolant​) is the temperature difference.


3. Simulation Approach

  1. Define Assumptions:

    • Cells are identical with uniform heat generation.
    • Steady-state heat transfer.
    • No phase change in coolant.
    • Neglect radiation losses.
  2. Modeling in a Thermal Simulation Software:

    • Set up the geometry (5-cell module, aluminum casing).
    • Apply boundary conditions (heat generation, ambient temperature, inlet temperature).
    • Solve for steady-state temperature distribution.
  3. Analytical Estimation (Simplified Approximation):

    • Calculate the heat dissipation rate for air and liquid cooling.
    • Estimate maximum cell temperature in both cases.


4. Expected Results

  • Air Cooling: Higher cell temperatures due to lower heat transfer coefficient.
  • Liquid Cooling: Better thermal performance, leading to lower cell temperatures.
  • Comparison: Plot temperature profiles, heat dissipation rates, and cooling effectiveness.
Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.