Question 1.
Solution. Given the parameters for the battery pack:
- Power requirement: 150 kW
- Voltage requirement: 120 V
- Cell chemistry: NMC (Nickel Manganese Cobalt), 3500 mAh (3.5 Ah), 3.6 V nominal
Step 1: Calculate the Number of Cells in Series (Voltage)
Each individual NMC cell has a nominal voltage of 3.6 V. To achieve a total of 120 V, the number of cells in series (S) can be calculated as:
S=3.6V/cell120V=33.33≈34cells in series
Thus, we will use 34 cells in series to achieve the required voltage.
Step 2: Calculate the Number of Cells in Parallel (Capacity)
The total energy needed is 150 kW, and we are aiming for a 120 V battery pack. The required total energy in Watt-hours (Wh) is:
Total Power=150kW×1hour=150,000Wh
The energy provided by one cell (assuming nominal voltage of 3.6 V and capacity of 3.5 Ah) is:
Energy per cell=3.6V×3.5Ah=12.6Wh
The total number of cells required to meet the total energy demand is:
12.6Wh/cell150,000Wh≈11,905cells
Since we have 34 cells in series, the number of cells in parallel (P) would be:
P=3411,905≈350cells in parallel
So, for the battery pack, we will have 34 cells in series and 350 cells in parallel.
Step 3: Pack Configuration
To summarize, the battery pack configuration consists of:
- 34 cells in series (S) for voltage
- 350 cells in parallel (P) for capacity
This results in:
Total number of cells=34×350=11,900cells