Project 1
A residential society has 200 x 2BHK flats and 100 x 3BHK flats. A typical family in a 2BHK flat has 3 persons/flat and a 3BHK has 4 persons/flat. The gross water demand (per person per day in liters) can be calculated by taking the aggregate if the usage for all the below listed activities.
Activities Consumption (per person/day in liters)
Drinking 5
Cooking 45
Bathing 30
Toilet Flushing 25
Cloth Washing 35
Miscellaneous 10
As per given data total persons in the residential society is 1000.
Per day one person water usage is 150 liters.
Total water consumption per day in residential society is 150000 liters.
Constraints & Site Data:
- One of the dimensions of the underground water tank is limited by the width of the internal road in the residential society as this is the ideal location of an underground water tank in case of a fire emergency. The width of the road could be taken as 6 meters and thus the width dimension of the tank cannot exceed 6 meters.
- The bearing capacity of the soil at different founding depths is given in the table below.
Founding Depth (below F.G.L) S.B.C (tones/sqm)
-3.00 m LVL 7.5
-4.00 m LVL 8
-5.00 m LVL 8.5
Consider an allowable soil settlement of 25 mm under the base slab.
- The top cover slab has a maximum one-way direction span of four meters and a thickness of 500mm. If the top slab span is greater than 4 meters, use a structural beam with dimensions of 500 by 900 (minimum concrete grade M25) to break the span. It should be noted that the current problem statement does not require the design of the beam or the top slab.
Loadings:
- The maximum superimposed dead load for the top cover slab is 3 KN/m2, and the maximum live load that should be considered is 15 KN/m2.
- Think about the weight of water in units of 10 kNm3 and soil in units of 18 KN/m3. It is necessary to take into account the soil's saturation level.
Make a full-scaled 3D STAAD pro model of the subterranean water tank that complies with the site's limitations, the estimated demand, and the FEA best practice recommendations. All relevant loadings on the structure, support conditions, material specifications, and an average mesh size of 500 mm should be included in the final model. The center line technique will be used to model all of the geometry, and the model must be error- and warning-free.
Materials unit weight as per the code
Safe Bearing Capacity = 18 KN/m^3
Plain cement concrete = 24 KN/m^3
Reinforcement concrete = 25 KN/m^3
Cement concrete screed = 20 KN/m^3
Cement masonry = 22 KN/m^3
Structural steel = 78.5 KN/ m^3
Loads of a building
Slab weight = 3.75KN/m^2(0.15mx25KN/m^3)
Partitions = 1.5 KN/m^2
Floor finish = 2.5 KN/m^2
Others = 1 KN/M^2
Total floor load = 8.75KN/m^2
Weights of slab units
Slab weight = 3.75kN/m^2(0.15mx25kN/m^3)
Waterproofing and insulations = 0.5 KN/m^2.
Services for MEP = 0.5kN/m^2.
Others = 0.5kN/m^2.
Roof load total = 5.25 KN/m^2
Shared corridor: 3 KN/m^2.
Floor load total = 3kN/m^2.
Roof accessibility = 1.5 KN/m^2.
Roof load total = 1.5 KN/m^2.
Design of slab(IS-456)
Span shorter direction(clear) Ly = 3.125m
Span longer direction(clear) Lx = 5.5m
Live load on the slab(LL) = 3kN/m
Compressive strength of concrete(Fck) = 25N/mm^2
Yield strength of steel(Fy) = 415N/mm^2
Unit weight of concrete(Yc) = 25kN/m^3
Unit weight of floor finish 100mm(Y) = 22kN/m^3
Clear concrete cover = 25mm
Bearing slab(B) =250mm
Step-1
L/d = 32 is the span to effective depth ratio.
Effective depth minimum (d) = 97.67 mm.
Depth total (D) = 127.66 mm.
Bars' diameter in the shorter direction = 10 mm.
Bar diameter in the extended direction = 10 mm.
120mm is the effective depth(d).
Loading on the slab
Dead load of the slab(DL) = 3.75kN/m^2
Super dead load = 5kN/m^2
Live load on the slab = 3kN/m^2
Total load on the slan = 11.75kN/m^2
Design load = Total load x load factor
= 17.63kN/m^2
Effective span Lx = 3.25m
Ly = 5.62m
Lx/Ly = 1.732 (two way)
| 1.5 | Alpha x | 1.75 | Alpha y | |
| For negative moments (at top) | 0.075 | 0.104683 | 0.107 | 0.084 |
| For positive moments (at bottom) | 0.056 | 0.103307 | 0.107 | 0.063 |
Step - 2
BM per unit width of slab
| Mx=αxwLx^2 | My=αywLy^2 | |
| For negative moments (at top) | 19.43 | 15.59kN-m/m |
| For positive moments (at bottom) | 19.17 | 11.69kN-m/m |
Shear force V = 0.5WLx =28.6 KN/m
Step - 3
To check the effective depth of slab
Mu,lim = 0.138Fck bd^2
d= 74.55mm
Step - 4
Depth of slab for shear force
Tc, max = 3.1N/mm^2
Tc = 0.3
K = 1.2
D = 200 mm
Tc = 0.3N/mm^2
Tv = Vu/bd
= 0.24/mm^2
Tv
0.24<0.36<3.1
SAFE
Step - 5
Estimating the steel's area
Mu = 0.87FyAstd(Fck bd - 1-AstFy)
For negative moment
Mu(top) = 19.43 KN/m
Ast = 561.65mm^2/m
For positive moment
Mu(bottom) = 19.17kN/m
Ast = 554.27mm^2/m
Determination of distribution steel
Astmin = 0.12bd
= 114mm^2
Selection of steel reinforcing bars
Area of bars(Top steel) = 78.5mm^2
Spacing = 140mm
= 125mm
provide 16mm bars at a spacing 125mm
Area of bars(Bottom steel) = 78.5mm^2
Spacing = 142mm
=125mm
Provide 16mm bars at a spacing 125mm
Calculation of wind load (IS875-Part 3)
Design wind speed Vz = Vbk1k2k3k4 m/s
Basic wind speed(Bangalore) Vb = 33m/s
Probability factor k1 = 1
Terrain factor k2 = Category 4B
Topography factor k3 = 1
Design wind pressure Pz = 0.6Vz^2
| Floor | Height | k2 | Vz | Pz | Pz in kN |
| 1 | 3.5 | 0.76 | 25 | 377.40 | 0.38 |
| 2 | 7 | 0.76 | 25 | 377.40 | 0.38 |
| 3 | 10.5 | 0.76 | 25 | 377.40 | 0.38 |
| 4 | 14 | 0.76 | 25 | 377.40 | 0.38 |
| 5 | 17.5 | 0.76 | 25 | 377.40 | 0.38 |
| 6 | 21 | 0.76 | 26 | 397.53 | 0.40 |
| R | 24.5 | 0.76 | 26 | 461.04 | 0.46 |
Calculation of seismic load (IS1893-Part 1)
Design base shear = VB = Ah x W
Where,
Ah = horizontal seismic coefficient as calculated as per 6.4.2
W = Total weight of the structure
Zone factor Z = 0.1 (Bangalore)
Soil condition factor Sa/g
Height of building h = 24.5m
Base dimension of building
Along-X = 25m
Along-Z = 16m
T along-X = 0.5513sec
T along-Z = 0.4410sec
Sa/g for hard soil = 1/T = 1.814 Along X
= 2.268 Along Z
Response reduction factor R = 3
Importance factor I = 1.2
Horizontal acceleration co-efficient Ah = 0.0363
= 3.6812%
Seismic weight
Area of each floor A = 400m2
Due to dead loads Typical floor DL = 12.5kN/m2
W DL = 5000kN
Due to dead loads, roof
DL roof = 9kN/m2
W DL roof = 3600kN
Due to live loads, Typical floor LL = 3kN/m2
W LL = 300kN/m2
Due to live loads, Roof LL = 1.5kN/m2
W LL roof = 0
Total seismic weight W = 35400kN
Design base shear VB = Ah x W
= 1605.44kN