Project 1
1.Design of Battery pack configuration:
Given,
Load Rated Power Rating : 150 KW
Load rated Voltage : 120 V
Cell :
cell nominal voltage : 3.6 V
Cell Nominal capacity :3.6 Ah
number of cells in series = Load Rated Volatge/ Nominal cell voltage
Number of cells in series = 120/3.6 = 33.33
Case 1 : Rounding off to 33 (NMC)
NBV = 3.65 * 33 = 120.45 V
LBV = 4.2 * 33 = 138 .6 V
Min BV = 2.5 * 33 = 82.5 V
Case 2 : Rounding off to 34 (NMC)
NBV = 3.65 * 34 = 124.1 V
LBV = 4.2 * 34 = 142.8 V
Min BV = 2.5 * 34 = 85 V
this case we shall choose case 2.
Number of cells in parallel :
Since 3500 mAh is the NMC cell capacity ,
Number of cells in parallel * cell capacity = battery capacity
Number of cells in parallel = 1.25 / 3.6 = 0.34 = 1
Battery Configuration : 33S 1P
2. Master Slave topology MCU AFE 1 (16 cells) total 33 cells (AFE1 connected to AFE 2)
AFE 2 (17 cells) (AFE 2 connected to MCU)