Identification of Cracks
(a)
ans:-
- Its Form of Flexural failure due to reversal of stress during earthquake.
During stress reversal ,support top experiences compression and bottom experiences tension.
- Top compression is managed by slab advantage .bottom tension was not satisfied by provided reinforcement.
- since the reinforcement got yielded,it can not be repaired.
(b)
ans:-
- It Beam pull out failure due to insufficient development length of reinforcement in joints.
- During Earthquake, the horizontal movement of structure makes the condition worse and detached the beam member from column.
- Providing anchorage length between two existing concrete is very difficult .So not repairable.
(c)
ans:-
- It's a plastic hinge failure'
- The damage occurred only in the joint zone first of all'
- cyclic lateral loading &stress reversal at the joints led to the damage.
- Even the slab participated to its best to handle the tension but unable to control the damage'
- The joint can be Strengthened.
2
(a)
ans:-
- It's a soft storey failure ,Technicaally Plastic Hinge Formation .
- Due to absence of infill walls at the Ground floor ,the Plastic hinge forms at the top of ground Storey columns During Lateral Movement.
- Based on the development of crush of concrete it can Either be repairable Or Non-repairable.
(b)
ans:-
- It's a pure Shear failure.
- Inadequate shear reinforcement compels concrete takes all the shear stresses.
(c)
ans:-
- It's a short Column Failure
- An additional Slab Or a Beam Connected to a Column In mid-height leads to this effect.
- The leads to failure especially if the connection is unintentional and not accounted in design.
- The failure Given in the picture is not at all repairable.