Answer 1. A

OBSERVATION:

As we can see that:

Concrete crushed and the reinforcement is exposed

Concrete spalled beyond the reinforcement which may be a sign of rupture

Beam top portion looks safe because of the flange advantage from slab

The crack developes from bottom to top means rebar yeilding occurs in support bottom only

RESULT:

Its form of flexural failure due to reverse of stress during earthquake

During stress reversal reversal, support top experiences compression and bottom experiences tension

Top compression is managed by slab advantage. Bottom tension was not satisfied by the provided reinforcement

Since the reinforcement got yielded, it can not be repaired

Answer 1. B

OBSERVATION:

Cracks along Beam- Column edge

Cracks seem to have developed thrugh the structure as it looks much wider

Beam looks separated from the column at joints

Concrete is not severely crushed

RESULT:

Its a Beam pull out failure due to insufficient developmen length of reinforcement in joints

During earthquake, the horizontal movement of structure makes this condition worse and detached the beam member from column

Providing anchorage length between two existing concrete is very difficult.So its not repairable

Answer 1. C

OBSERVATION:

Cracks are exactly at the joint of column- Beam

Cracks in Beam developed through its entire width

Slab also developed more cracks along the beam width direction

RESULT:

Its a plastic hinge failure

The damage occured only in the joint zone first of all

Cyclic lateral loading and stress reversal at the joints led to damage

Even the slab participated to its best to handle the tension . Slab is severly cracked means it has undergone tension with its flange condition.But unable to control the damage

The joint can be strengthed therefore repairable.

Answer 2. A

OBSERVATION:

Concrete damaged at top of the column

Concrete damaged all round the column face

Beams are safe

The location of column looks at edge of the building

No walls are built along the column means it is probably at ground floor, for parking car movement access

RESULT:

Its a soft story failure, Technically plastic hinge formation

Due to absence of infill walls at the ground floor,The plastic hinge forms at the top of ground story column durin lateral movement

Based on the development of crush of concrete it can be either repairable or non repairable

Answer 2. B

OBSERVATION:

Concrete developed complete breakage diagnolly

Longitudnal reinforcements are intact

Shear reinforcement spacing looks wider which means probably lesser shear rebar provided

RESULT:

Its a pure shear failure

Inadequate shear reiforcement compels concrete takes all the shear stresses

Answer 2. C

OBSERVATIONS:

Column failed completely

Failure at top of column

There are two slabs connected to columns , probably one at mid of the column

The wooden piles might be a post failure support after column failed, providing temporary prop to avoid collapse of the entire structure

RESULT:

Its a short column failure

An additional slab or a beam connected to a column in mid height leads to its effects

This leads to failure especially if the connection is unintentional and not accounted in designs

The failure shown in the picture is not at all repairable