Identification of Cracks
1.a)-its form of flexural failure due to reversal of stress during earthquake.
-during stress reversal, support top experiences compression and bottom experiences tension.
-top compression is managed by slab advantage.buttom tension was not satisfied by the provided reiforcement.
-since the reinforcement got yeilded, it can not be repaired.
b)-its beam pull out failure due to insufficient development length of reinforcement in joints.
-during earthquake, the horizontal movement of structure makes this condition worse and detached the beam member from column.
-providing anchorage lenth between two existing concrete is very difficult. so not repairable.
c)-its a plastic hinge failure.
-the damage occurred only in the joint zone first of all.
-cyclic lateral loading and stress reversal at the joints led to the damage.
-even the slab participated to its best to handle the tension but unable to control the damage.
- the joint can be strengthened.
2.a)-its a soft storey failure, technically plastic hinge formation.
-due to absence of infill walls at the ground floor , the plastic hinge forms at the top of ground storey columns during lateral movement.
-based on the development of crush of concrete, it can either be repairable or non-repairable.
b) -its a pure shear failure.
-inadequate shear reinforcement compels concrete takes all the shear stresses.
c)- its a short column failure.
- an additional slab or a beam connected to a column in mid-height leads to this effect.
-this leads to failure especially if the connection is unintentional and not accounted in design.
-the failure given in picture is not at all repairable.