Challenge

Foundation Design using SAFE

ANSWER:

COMPLETE STEPWISE PROCEDURE TO DESIGN ISOLATED FOOTING AND PILE FOUNDATION USING SAFE

1. ISOLATED FOOTING:

  • Initial Design Setup
  1. Download the SAFE software from the official CSI website, to begin with, the project.
  2. Locate the software in your machine at the desired disk.
  3. Then, open the software after installing it.
  4. Then, you will find a similar user interface as included in ETABS.
  5. So, click on the new model option as we do while designing in ETABS.
  6. Then, there will be a few footing templates made available to you by the software.
  7. So, choose the isolated footing option from the list and feed the footing details.
  8. In the detail section, you need to insert the length, breadth, and depth of footing.
  9. At the same time, you can also define the load type and intensity in the same section.
  10. It saves you time from having to apply load manually after modeling.

  • Define Material Properties
  1. Like we did in ETABS, we need to define the material properties in an exact manner.
  2. However, we don't need to have shear ties for footings. So, don't define fe415. Just define concrete and fe500 and that's it.
  3. The same is shown below:

M25

FE 500

  • Define Section Properties
  1. This can also be done the same way as ETABS.
  2. But here, we need to define two different types of slabs. One is the footing slab and the other is the stiff slab for the column area over the footing.
  3. However, the depth of both the slabs shall remain the same as calculated from the pressure formula.
  4. Also, make sure to select the property type as footing and stiff respectively while defining the slabs.

Footing Slab

Stiff Slab (for the column portion)

  • Define the Load Combinations
  1. The procedure is exactly the same as we do in ETABS.
  2. However, we need to define two types of load combos for footing that are service load and ultimate load combinations.
  3. In the service load combination (SLS) total unfactored column load will be accounted for.
  4. Whereas in the case of ULS, a factor of 1.5 shall be multiplied by the dead and live loads.
  5. So, the same is done as follows:

SLS Load Combo

ULS Load Combo

  • Load Assignments
  1. We have already assigned loads while defining the footing section in the beginning.
  2. However, we need to check if the loads are appropriately located or not.
  3. And for this, go to display>show loads assigned>dead/live>ok.

Dead Load

Live Load

  • Define and Assign Soil Spring
  1. Spring constant for soil is given by the formula: Factor of safety x soil bearing capacity / allowable settlement.
  2. So, calculate the same based on your soil report then define the same from define>soil properties.
  3. Then, select the footing>go to assign>area spring>spring1>ok.
  4. The procedure for the same is shown below:

  • Run the Analysis and Design
  1. After assigning the load patterns and the soil spring, our model is set to be run for analysis.
  2. Also, unlike ETABS, safe runs the analysis and designs the section for you at the same time.
  3. However, there are a few checks you need to make once the analysis and design are completed and the same is discussed in the below sections.
  • Check for Settlement
  1. The first thing we need to observe is the total footing slab settlement measured in mm.
  2. And to do so, go to display>show deformed shape>SLS load combo>ok.
  3. SAFE will show you the total displacement in mm due to the said load combination.
  4. And it should be within the limits specified by the codes.
  5. So, for isolated footings, 25mm of maximum displacement is allowed as per the codebook.
  6. And the settlement in case of our footing is inserted below that is way less than the said limit. Hence OK.

  • Check for Soil Pressure
  1. Now we need to see if the soil pressure due to the service load combination is within the range of soil bearing capacity as received from the soil report.
  2. And to do that, go to display>soil pressure>SLS load combo>ok.
  3. The same is shown below which in our case is 149 KN/sq.m < 150KN/sq.m. Hence OK.

  • Run the Analysis and Design
  1. Now that all things are set, we can run the analysis and design by clicking on the play button from the top tool ribbon in SAFE.
  2. The analysis will get completed within a few seconds and we will need to execute several checks as we did in the case of the isolated footings.
  3. So, the procedure shall be exactly the same and you can refer to the isolated footing section for a more detailed procedure.
  4. Here, we have included the final results of the design check as follows:
  • Check for Settlement

  • Maximum displacement (6.77mm) is way lesser than the permissible value stated by the codes (25mm). Hence, OK.
  • Punching Shear Check

  • Allowable punching shear value is equal to unity. Hence, OK.
  • Base Reactions at Piles

  • Our pile bearing capacity is 200KN. Hence, OK.
  • Longitudinal Reinforcement Requirement

Maximum Rebar Area for Design Strip A

Maximum Rebar Area for Design Strip B