Challenge

Foundation Design using SAFE

AIM: Design of Foundation using SAFE v20

INTRODUCTION:

  • CSI SAFE (Slab Analysis by the Finite Element method) is the best tool for designing concret slabs and foundations.
  • SAFE provides easiness to engineer towards the safe desing of strructures with powerful tools like draw, analyze, design and detailing, etc.

PROCEDURE:

  • Open the SAFE Application

  • Select New model
  • Select the units and Design codes.
  • Single Footing was selected next

Subgrade Modulus =

Where, FOS for soil = 3

S.B.C = 150KN/m^2

Settelement for Isolated footing = 25mm

Hence; Subgrade modulus = 18000 KN/m/m^2

The compression axial load for the load combination (1.5 DL+1.5LL) is 2000KN.

Unfactored load = 2000/1.5 = 1333.6KN

Live Load = 1333.6/2 = 666.5KN

Dead Load = 1333.6/2 = 666.5KN

Footing thickness 600mm

Column Load size = 400 x 400 mm

Given data,

Define Materials

----> Go to the Define Tab and select Material property.

  • Add M25 concrete
  • Add new propety as Rebar.

Define Section Property

  • Next, Define Section Property
  • Go to Slab property.
  • Add mat > Thick shell -- > Mat type < 600 mm thickness

  • Add next STIFF property.
  • Change the type as Stiff

  • Now right click on slab / floor and change the section Property as Mat.
  • Now Right Click on Column and change the section Propety as STIFF.

Check the Forces Applied by Right click on column joints.


  • Apply Live Load of 2KN/m on the Footing/slab
  • Select the Slab and assign the uniform load of 2 KN.

Check the Load Patterns

  • Go to Define Tab spring properties
  • Click on Area Spring and change the name of (ASpr) as soil.

Define Load Combintion

  • Go to Define Tab and select Load combination
  • Add new Combo as SLS

  • Add new combo as ULS.
  • Click on the icon (Concrete slab/ Beam Design ) and Check the prefences like cover, bar dia etc.
  • Agian click on the Icon ( Concrete slab/ beam Design ) and go the Design Load Combination.
  • Add the combination.

Add Design Strips

  • Go to the edit tab and select Add/ Edit Design Strips.
  • or Add Manually Design Strip from the Draw Design Strip Tool.

Check the Model and Analyse.

Check the Displacement:

Max soil Pressure = 71.486 @ (0,0.2, 3) in SLS condition.

Checking Punching Shear

Here Punching Shear is 0.701 < 1 hence Ok.

Check Strip Design

Check on Layer B


RESULT:

Hence the Isolated Footing was designed and analyzed using SAFE successfully. The results of each drawing drawn in SAFE are attached.

AIM:

  • To model analyze and design the pile cap on SAFE.
  • To evaluate the following
  • Pile group to be used
  • Depth of pile cap
  • Longitudinal steel on top and bottom face in both directions

INTRODUCTION:

  • Pile foundations are deep foundations.
  • They are formed by long, slender, columnar elements typically made from steel or reinforced concrete, or sometimes timber.
  • A foundation is described as 'pilled' when its depth is more than three time its breadth.

PROCEDURE:-

Given Data:

Column size:- 600 x600

Unfactored load:- 1175KN

Pile lenght :- 16m

Pile Diameter :- 500mm

Load carring capacity :- 200KN

Calculations:

Number of pillers:- 1175 x 1.1 / 200 = 6.4

But we take 8 piles for the symmetric load distribution.

Spring Constant :- A x E/L

Where E is :- 5000 sqroot Fck

Area (A) is :-

  • Open the SAFE Application.
  • Select New model
  • Followed by input settings.
  • Units were selected as Metric and code IS:456-2000.

  • Add the grid in X and Y ordinates.

Define Material Property

  • Go to Define Tab and select Material Property.
  • Add New Property.
  • M25 grade of concrete

  • Add New Property as Rebar

Define Section Properties

  • Go to the Define TAB and select section Property
  • Add new section Property as pile ( As Mat material ), pile_Cap ( As Mat material) and Column (as STIFF material)

Draw the Floor/ Slabs

  • Go to the Slab/ Floor tool and select property as slab as pile_Cap.
  • Drag diagonally and draw slab/ floor.

Draw points

  • Go to the Draw tab and select Draw joints objects.
  • Now the Draw the Joints where i want.
  • Now Draw the Pile
  • Go to the Quick draw area around point Tool.
  • Select Shape as Circular and Property as Pile.
  • Draw piles on all the joints except center joints.
  • Now Draw Column in center.
  • Again select quick draw area around point and shape as rectangle and property name as Column.

Define Point Spring

  • Go to Define property and select Spring Property.
  • Click on point Spring Property and Change the Data

Assign the Point Spring


  • Select the all piles joints and go to assign and select joints Assignment.
  • Select point Spring to assign it.

Assign Point load:

  • Select middele joints of column and apply load by assigning Tab > Joints Load
  • Next, Add Dead and live load of 587.5KN


Assign Point load:

  • Select middel joints of column and apply Load by assigning Tab > Joints Load
  • Next, Add Dead and Live load of 587.5KN

Define Load Combination

Add Design Strips:

  • Go to edit Tab and select Add Design Strips Along X-A and Y-B.

Add Design Load Combination:

Now Run the Analysis and Check the Results

MAX DISPLACEMENT = 0.655 @(1.75,1.75,3)

Punching Shear is lee than 1, Hence ok.

Support Reactions (Dead +Live ) = max 123.33 >200.


Show Slab Design

Reinforcement Detail

Maxm X-A = 1129mm^2

Max in Y -B = 1152mm^2

RESULT:-

Hence, Complete the design of the pile cap foundation using SAFE Software. The result of each drawing drawn in SAFE are attached.

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.