Challenge

Conceptual design of a building with columns and shear walls

1A)

CASE A)

Restraint of floor shrinkage 

obesrvation full restraint at all corner 

conclusion option a will have higher restraint to shrinkage thus lead to crack in the floor, option B is average option C will not effectively restraint the srinkage so possibly less cracks 

The lateral stiffness 

obesrvation comparatively lower lateral stiffness in both X and Y

conclusion option b will provide higher lateral stiffness for a pure seismic acceleration X and Y direction 

Torsion with respective vertical axis

observation Corners walls provide more resistance to twist 

coclusion option a will be the best option respect to torsional resistance wheras option c is the wrost one 

Vertical reinforcement for similar base capacity 

observation walls are subjected to nominal flexural moment and heavy twisting moment 

conclusion only c will required heigher vertical reinforcement and option b will required least

static eccentricity 

observation structurally symmetric

conclusion only option C have static eccentricity and it is significant 

system redundancy 

obseravation uniform placement of lateral load support in both the axes 

conclusion option a and b are more retundant than c

foundation system

observation Due to L shaped wall the geometry of foundation and its design will be critical 

conclusion option B and C will be incorporated with isolated/strip footing option a is recommended to have peripheral box foundation 

Architectural constraints 

observation walls obstruct only corners 

conclusion Architecturally speaking option a the preffered one option b is subjected to discussion option c will not be accepted both architecturally and commercially

CASE B) 

Restraint of floor shrinkage 

obesrvation corners are left free but restrain along the edge 

conclusion option a will have higher restraint to shrinkage thus lead to crack in the floor, option B is average option C will not effectively restraint the srinkage so possibly less cracks 

The lateral stiffness 

obesrvation comparatively higher lateral stiffness in both X and Y

conclusion option b will provide higher lateral stiffness for a pure seismic acceleration X and Y direction 

 

Torsion with respective vertical axis

observation edge walls provide good resistance to twist 

coclusion option a will be the best option respect to torsional resistance wheras option c is the wrost one 

 

Vertical reinforcement for similar base capacity 

observation walls are subjected to nominal twisting moment  

conclusion only c will required heigher vertical reinforcement and option b will required least

static eccentricity 

observation structurally symmetric

conclusion only option C have static eccentricity and it is significant 

system redundancy 

obseravation uniform placement of lateral load support in both the axes 

conclusion option a and b are more retundant than c

foundation system

observation walls are in line easy to fix the geomentry and design of foundation  

conclusion option B and C will be incorporated with isolated/strip footing option a is recommended to have peripheral box foundation 

Architectural constraints 

observation walls obstruct the faces of building  

conclusion Architecturally speaking option a the preffered one option b is subjected to discussion option c will not be accepted both architecturally and commercially

CASE C) 

Restraint of floor shrinkage 

obesrvation non uniform restraints 

conclusion option a will have higher restraint to shrinkage thus lead to crack in the floor, option B is average option C will not effectively restraint the srinkage so possibly less cracks 

The lateral stiffness 

obesrvation non uniform lateral stiffness in both X and Y

conclusion option b will provide higher lateral stiffness for a pure seismic acceleration X and Y direction 

Torsion with respective vertical axis

observation irregular walls are provide very poor resistance to twist 

coclusion option a will be the best option respect to torsional resistance wheras option c is the wrost one 

Vertical reinforcement for similar base capacity 

observation walls are subjected to nominal flexural moment and twisting moment 

conclusion only c will required heigher vertical reinforcement and option b will required least

static eccentricity 

observation structurally un-symmetric

conclusion only option C have static eccentricity and it is significant 

system redundancy 

obseravation concentrated lateral load support in both the axes 

conclusion option a and b are more retundant than c

foundation system

observation walls are in line & concentrated easy ton fix the geomentry of foundation but critical in design

conclusion option B and C will be incorporated with isolated/strip footing option a is recommended to have peripheral box foundation 

Architectural constraints 

observation vertical wall will not allow passage  

conclusion Architecturally speaking option a the preffered one option b is subjected to discussion option c will not be accepted both architecturally and commercially

2A)

There is a two way eccentricity in the frame along X direction and Y direction also with stiffness the eccentricity in X direction is larger when compared to Y direction.

There is only two continuous frames in the structure that is B1 and B2 in the X direction and B9, B10 and B11,B12 in the Y direction and all other beams are broken at the midway in the frame.

There will be Torsional flexibility in the structure.To avoid torsional restraints it is better to make the room dimensions even in both X and Y direction and placing the columns at the junction of two wall if it is feasible better to provide shear wall at appropriate location.

The fundamental translation mode of vibration is larger than the fundamental torsional mode of vibration.

3A)

observation in the given framing plan 

Floor plan: 

 the floor plan of the building is not either uniform or symmetric so naturally any lateral load induced in the floor will not have 100% influence in same direction definately a special lateral load resisting system for these tortional moment should be accommodated 

 

Random internal column:

     since the internal column are random they are unable to transfer lateral load effectively and can not achieve desire building responce so we have to assume and design those columns for only gravity load 

Floor to floor variations in partition walls and beams 

     partition wall provide an importance mass control in a building plan key role in shear transfer from floor to beam all these elements are not in order so heavy distortion and distribution of lateral loads will happen 

Suggestion on the lateral load system and its foundation: 

heavy tortional forces should be contrrolled by respective lateral load system so corner shear walls are suggested 

the propotion of floor area is greater on ther left side than the right side so corners shear walls on left side should be havier than the right 

corner shear wall shall preferably be supported over a box foundation shear walls should be connected by link beam to transfer shear from one to the other

The internal columns shall be supported by isolated footing those isolated footing can be connected with shear walls through tie beam 