Challenge

Analysis & Design of RCC shear walls in the model using ETABS

DESIGN SHEELL WALL

elevation drawig of reinforcement

procedure:

  • Extract values of longitudinal steel ratio, boundary element length and shear reinforcing ratio from the design results.
  • Provide cross sectional steel arrangement of the shear wall from its base up to terrace, in compliance with provisions of IS 13920 – 2016.

STORY DATA

VERTICLE SHEAR WALL A11

HORIZONTLE SHEAR WALL

BOUDRY ZONE WIDTH

DETAILING GUIDLINES FOR SHEAR WALL

min reinforcement for shrinkAFE ANDtemp

ultimate limit state design rebar element} whichever is grater should be drawen in rc shear wall detailing

ductility rebar requirment

classification of shear wall as per IS-13920clause10.4 slender wall

hw/Lw=21000/1500=14>2

min net verticle reinforcement as per IS-13920-2016 table-1 -3 =2363mm2

0.0025+(300/1500)

min verticle reinforcement within boundry element table-1-3

1440mm2 on left (60mm width boudry element

1440mm2 on right (60mm width boudry element

MIn horizontle reinforceent in shear wall as IS 13920-2016 table 1-3

=750(300*100)=0.0025,hw=2100hw=2100Lw=1500

=0.0025+0.5(21/15-2)*0

=0.0025which is same as 750mm2

max dia of rebar for shear wall as per is =13920-2016 clause 10.1.8

commercial rebar dia 25mm shall be adopted

confining reinforcement spacing for boundry wall as per is -13920-2016 clause 10.4.4

  • 1/3rd of min member dimention =300/3
  • 6 times smallest main bar =6*25 =150mm
  • 150mm permisible if verticle bars are spaced at max 200m

max spacing of confining reinforcement boundry element 150mm

confining reinforcement within boundry element as per is-13920 clause 10.4.4

resuly:

Ash=0.05Svhfck/fy

Sv =150mm

h=1000mm

Ash=452mm2

commercial rebar dia 25mm shall be adopted