Project

Conjugate Heat Transfer simulation-PipeFlow

Flow simulation was setup up using Converge Studio, and post processing was carried out in Paraview.

Inlet Reynold number-10000

Inflow velocity- 5m/s

Turbulence model- K-epslon model

Super-cycling modelling was carried out for overcoming time-scale disparity. In super-cycling, the fluid solver is frozen periodically while the heat transfer in the solid is allowed to progress to steady-state. CONVERGE solves the fluid and solid phases in the same simulation without requiring you to stop and restart the simulation. Super-cycling significantly reduces the computational cost of the CHT simulation.

1. Base grid: 0.004 m. (Velocity and Temperature Plots)

Temperature vs time- at the selected point near outflow of pipe:

Vector Plot:

2. Base grid: 0.006m.

Temperature vs Time at selected outflow point:

It looks like, varying the grid size, did effect the converged value of temperature to an extent (about 2-3%).

3.Base Grid: 0.002m.

Temp vs time for outflow selected point:

Now when the grid size is decreased, the effect on the converged results is bit substantial (about 12% variation).

4. Effect of Supercyclic stage interval on simulation time:

interval--0.03:

Time:1077 secs approx.

interval-0.02:

Time: 1485 seconds approx

interval-0.01

Time: 2178 secs. approx

With decrease in cycling interval, simulation time increased which was expected, because fluid scale solver is frozen more periodically, as periodic interval is less.

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.