Project

Buckling analysis on a cyclonic separator stand

OBJECTIVE:

  1. To perform a buckling analysis on a cyclonic separator stand to understand its buckling characteristics.
  2. To perform a buckling analysis on the same model with a metallic stiffener added and evaluate the change in the buckling factor of safety.
  3. To perform a parametric design study on the model to find the optimum position of stiffener and the thickness of the stiffer, to maximise the buckling factor of safety.

GEOMETRIC MODEL:

The geometric 3D model of the cyclonic separator stand was provided along with the tutorial. The unnecessary parts in the model were suppressed and saved into a part file format (.sldprt). The new saved model was opened using Solidworks.

BOUNDARY CONDITIONS:

The same boundary conditions were applied to all the three models;

  • Buckling analysis under the new study was selected.
  • Material applied - Alloy steel
  • Fixtures - The four legs of the cyclonic separator stand was fixed.
  • Load - A load of 150kN was applied on the top face of the stand.
  • Mesh- Mesh size of 18mm with tolerance size of 0.9mm were used.

CASE 1 - BUCKLING ANALYSIS WITHOUT STIFFENER:

  • The boundary conditions were applied to the model.
  • The study was run to solve the simulation.

RESULTS:

INFERENCE:

The buckling factor of safety of 9.3547 was obtained under the given conditions. The structure is stable under the loading conditions and is not expected to fail.

CASE 2 - BUCKLING ANALYSIS WITH STIFFENER:

  • A stiffener was added to the structure at a bottom offset of 1000mm from the top face of the stand. Stiffener thickness of 75mm was defined.
  • The boundary conditions were applied.
  • The study was run to solve the simulation.

RESULTS:

INFERENCE:

The buckling factor of safety of 27.577 was obtained under the given conditions. Thus, the structure has become better compared to the earlier design without stiffener. The design has become 3 times better compared to previous. The structure is stable under the loading conditions and is not expected to fail.

CASE 3- PARAMETRIC STUDY TO DETERMINE THE OPTIMUM POSITION AND THICKNESS OF STIFFENER

A parametric design study was started. The following things were defined.

Variables:

  • Offset distance of stiffener moved from 250mm to 1500mm with a step value of 250mm.
  • The thickness of stiffener changed from 20mm to 120mm with a step value of 20mm.

Constraints:

  • The minimum buckling factor of safety was set to 25

Goal:

  • Maximise the buckling factor of safety.
  • Minimise the thickness of the stiffener.
  • Total no. of scenarios 36.

RESULTS:

Component name

Units

Current

Initial

Optimal

Scenario1

Scenario2

Stiffener thickness

mm

75

75

75

20

40

Offset distance

mm

1000

1000

1000

250

250

Buckling Factor of Safety1

27.576529

27.576529

27.576529

10.008496

10.991599

Buckling Factor of Safety2

27.576529

27.576529

27.576529

10.008496

10.991599

Dimension1

mm

75

75

75

20

40

Component name

Units

Scenario3

Scenario4

Scenario5

Scenario6

Scenario7

Stiffener thickness

mm

60

80

100

120

20

Offset distance

mm

250

250

250

250

500

Buckling Factor of Safety1

11.767163

12.177147

12.396346

12.523006

10.438522

Buckling Factor of Safety2

11.767163

12.177147

12.396346

12.523006

10.438522

Dimension1

mm

60

80

100

120

20

Component name

Units

Scenario8

Scenario9

Scenario10

Scenario11

Scenario12

Stiffener thickness

mm

40

60

80

100

120

Offset distance

mm

500

500

500

500

500

Buckling Factor of Safety1

13.141742

14.976645

15.858685

16.322100

16.586916

Buckling Factor of Safety2

13.141742

14.976645

15.858685

16.322100

16.586916

Dimension1

mm

40

60

80

100

120

Component name

Units

Scenario13

Scenario14

Scenario15

Scenario16

Scenario17

Stiffener thickness

mm

20

40

60

80

100

Offset distance

mm

750

750

750

750

750

Buckling Factor of Safety1

10.846201

15.836319

19.676456

21.549610

22.518213

Buckling Factor of Safety2

10.846201

15.836319

19.676456

21.549610

22.518213

Dimension1

mm

20

40

60

80

100

Component name

Units

Scenario18

Scenario19

Scenario20

Scenario21

Scenario22

Stiffener thickness

mm

120

20

40

60

80

Offset distance

mm

750

1000

1000

1000

1000

Buckling Factor of Safety1

23.050318

10.944871

17.348551

23.990150

28.554022

Buckling Factor of Safety2

23.050318

10.944871

17.348551

23.990150

28.554022

Dimension1

mm

120

20

40

60

80

Component name

Units

Scenario23

Scenario24

Scenario25

Scenario26

Scenario27

Stiffener thickness

mm

100

120

20

40

60

Offset distance

mm

1000

1000

1250

1250

1250

Buckling Factor of Safety1

31.553377

33.405010

10.648359

15.506347

19.686344

Buckling Factor of Safety2

31.553377

33.405010

10.648359

15.506347

19.686344

Dimension1

mm

100

120

20

40

60

Component name

Units

Scenario28

Scenario29

Scenario30

Scenario31

Scenario32

Stiffener thickness

mm

80

100

120

20

40

Offset distance

mm

1250

1250

1250

1500

1500

Buckling Factor of Safety1

22.174479

23.832024

25.112261

10.121953

12.783618

Buckling Factor of Safety2

22.174479

23.832024

25.112261

10.121953

12.783618

Dimension1

mm

80

100

120

20

40

Component name

Units

Scenario33

Scenario34

Scenario35

Scenario36

Stiffener thickness

mm

60

80

100

120

Offset distance

mm

1500

1500

1500

1500

Buckling Factor of Safety1

14.924836

16.215261

17.115261

17.837139

Buckling Factor of Safety2

14.924836

16.215261

17.115261

17.837139

Dimension1

mm

60

80

100

120

INFERENCE:

Based on the parametric study, the optimum offset distance of the stiffener and the thickness of the stiffener was found to be 1000mm and 75mm respectively. When you go through the results table, you may find the conditions which give more buckling FOS with more thickness. However, the optimised result will be the one with 1000mm offset and 75mm thickness.

CONCLUSION:

All three objectives were studied. Under the loading condition without stiffener, the Buckling FOS was 9.3547. It was made better to 27.577 with the addition of a stiffener of thickness 75mm at an offset of 1000mm from the top surface. Under the parametric study, the same design yielded the optimum solution.

Your portfolio, next

Ship work like this
in your own course.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.

Talk to a career counsellor

Free 20-minute call. We'll map the right course to where you want to work.

By submitting you agree to our Terms and Privacy Policy.