Sketch a G+1 residential plan according to Vaastu Shastra and Calculation of Loads as per IS code
AIM : Drafting a Residential Plan of G+1 floors according to the Vaastu Shastra.
Introduction: The designing and drafting the residential house, emphasizing on the vaastu shastra. Alongside of the plan, a set of essential structural drawings will be provided to the construction site, detailing the layout, dimensions and specifications.
The structural drawings that are provided to the site are:
- Centre Line Drawing
- Footing and Column layout with reinforcement details
- Column Schedule with reinforcement details
- Plinth Beam Layout with reinforcement details
- First floor beam layout with reinforcement details
- First floor slab layout with reinforcement details
- Head room reinforcement details
Calculating of Loads:
Load= Unit weight density* Volume
Deadload:
S.W due to Column (0.23*0.45)= 25*0.23*0.45=2.58 kN/m
S.W due to Beams (0.23*0.45)= 25*0.23*0.45=2.58 kN/m
S.W due to walls (3m height)= 25* 0.23* 3= 17.25 kN/m
Total Deadload= 22.41 kN/m
Slab Dead Load (150mm thickness) = 25* 0.15= 3.75 kN/m^2
Floor load: 2kN/m^2
Unknown load : 1.5 kN/m^2
Total Area load = 6.25 kN/m^2
Live Load= 2 kN/m^2
Combination of load =(DL+ LL)*1.5