Challenge

Foundation Design using SAFE

Model the isolated footing provided in week 11 challenge on SAFE. Analyze and design it to verify the size, depth and steel provided as per calculations.

2. A column of size 600x600 carrying an unfactored gravity load (DL+LL) of 1175 KN is to be supported on pile cap, which ultimately transfers load to the piles underneath. Piles of 16 metres length and 500 mm diameter are to be used. Each pile has a load carrying capacity of 200 KN. Model, analyse and design the pile cap on SAFE to evaluate the following:

Pile group to be used

Depth of pile cap

Longitudinal steel on top and bottom face in both directions

Note: Participants must refer to IS 2911 (part 2) and SP 34 for 2nd challenge